Thermal Guidelines for Data Processing Environments PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Thermal Guidelines for Data Processing Environments PDF full book. Access full book title Thermal Guidelines for Data Processing Environments by ASHRAE (Firm). Download full books in PDF and EPUB format.

Thermal Guidelines for Data Processing Environments

Thermal Guidelines for Data Processing Environments PDF Author: ASHRAE (Firm)
Publisher: Ashrae
ISBN: 9781936504336
Category : Buildings
Languages : en
Pages : 0

Book Description
There is often a mismatch of IT equipment environmental requirements with adjacent equipment requirements or with facility operating conditions and therefore a strong need to find common solutions and standard practices that facilitate IT equipment interchangeability while preserving industry innovation. Thermal Guidelines for Data Processing Environments provides a framework for improved alignment between IT equipment hardware manufacturers (including manufacturers of computers, servers, and storage products), data center designers, and facility operators and managers. This guide covers five primary areas: equipment operating environment guidelines for air-cooled equipment (six classes are defined), environmental guidelines for liquid-cooled equipment (five classes are defined), facility temperature and humidity measurement (to evaluate data center health), equipment placement and airflow patterns (a hot-aisle/cold-aisle layout is recommended), and equipment manufacturers' heat load and airflow requirements reporting. In reaction to the industry trend of increased energy efficiency for data center operation, this third edition of Thermal Guidelines for Data Processing Environments provides groundbreaking, vendor-neutral information that will empower data center designers, operators, and managers to better determine the impact of varying design and operation parameters. This book is the first in the ASHRAE Datacom Series, authored by ASHRAE Technical Committee 9.9, Mission Critical Facilities, Technology Spaces and Electronic Equipment. This series provides comprehensive treatment of datacom cooling and related subjects.

Thermal Guidelines for Data Processing Environments

Thermal Guidelines for Data Processing Environments PDF Author: ASHRAE (Firm)
Publisher: Ashrae
ISBN: 9781936504336
Category : Buildings
Languages : en
Pages : 0

Book Description
There is often a mismatch of IT equipment environmental requirements with adjacent equipment requirements or with facility operating conditions and therefore a strong need to find common solutions and standard practices that facilitate IT equipment interchangeability while preserving industry innovation. Thermal Guidelines for Data Processing Environments provides a framework for improved alignment between IT equipment hardware manufacturers (including manufacturers of computers, servers, and storage products), data center designers, and facility operators and managers. This guide covers five primary areas: equipment operating environment guidelines for air-cooled equipment (six classes are defined), environmental guidelines for liquid-cooled equipment (five classes are defined), facility temperature and humidity measurement (to evaluate data center health), equipment placement and airflow patterns (a hot-aisle/cold-aisle layout is recommended), and equipment manufacturers' heat load and airflow requirements reporting. In reaction to the industry trend of increased energy efficiency for data center operation, this third edition of Thermal Guidelines for Data Processing Environments provides groundbreaking, vendor-neutral information that will empower data center designers, operators, and managers to better determine the impact of varying design and operation parameters. This book is the first in the ASHRAE Datacom Series, authored by ASHRAE Technical Committee 9.9, Mission Critical Facilities, Technology Spaces and Electronic Equipment. This series provides comprehensive treatment of datacom cooling and related subjects.

Thermal Guidelines for Data Processing Environments

Thermal Guidelines for Data Processing Environments PDF Author: Ashrae
Publisher: Ashrae
ISBN: 9781939200020
Category : Buildings
Languages : en
Pages : 145

Book Description
"This guide covers equipment operating environment guidelines for air-cooled equipment, environmental guidelines for liquid-cooled equipment, facility temperature and humidity measurement, equipment placement and airflow patterns, equipment manufacturers' heat load and airflow requirements reporting, and methods for increasing energy efficiency and avoiding electrostatic discharge"--

Thermal Guidelines for Data Processing Environments

Thermal Guidelines for Data Processing Environments PDF Author:
Publisher:
ISBN: 9781621988144
Category : Buildings
Languages : en
Pages : 136

Book Description
"This third edition of Thermal Guidelines for Data Processing Environments breaks new ground through the addition of new data center classes enabling near full-time use of free cooling techniques in the vast majority of the world's climates"--

Data Center Handbook

Data Center Handbook PDF Author: Hwaiyu Geng
Publisher: John Wiley & Sons
ISBN: 1118436636
Category : Computers
Languages : en
Pages : 720

Book Description
Provides the fundamentals, technologies, and best practices in designing, constructing and managing mission critical, energy efficient data centers Organizations in need of high-speed connectivity and nonstop systems operations depend upon data centers for a range of deployment solutions. A data center is a facility used to house computer systems and associated components, such as telecommunications and storage systems. It generally includes multiple power sources, redundant data communications connections, environmental controls (e.g., air conditioning, fire suppression) and security devices. With contributions from an international list of experts, The Data Center Handbook instructs readers to: Prepare strategic plan that includes location plan, site selection, roadmap and capacity planning Design and build "green" data centers, with mission critical and energy-efficient infrastructure Apply best practices to reduce energy consumption and carbon emissions Apply IT technologies such as cloud and virtualization Manage data centers in order to sustain operations with minimum costs Prepare and practice disaster reovery and business continuity plan The book imparts essential knowledge needed to implement data center design and construction, apply IT technologies, and continually improve data center operations.

THERMAL GUIDELINES FOR DATA PROCESSING ENVIRONMENTS, 5TH EDITION

THERMAL GUIDELINES FOR DATA PROCESSING ENVIRONMENTS, 5TH EDITION PDF Author: ASHRAE (Firm)
Publisher:
ISBN: 9781947192652
Category : Buildings
Languages : en
Pages :

Book Description
"Covers equipment operating environment guidelines for air-cooled equipment, environmental guidelines for liquid-cooled equipment, facility temperature and humidity measurement, equipment placement and airflow patterns, equipment manufacturers' heat load and airflow requirements reporting, and methods for increasing energy efficiency and avoiding electrostatic discharge"--

Liquid Cooling Guidelines for Datacom Equipment Centers

Liquid Cooling Guidelines for Datacom Equipment Centers PDF Author:
Publisher: Ashrae
ISBN: 9781936504671
Category : TECHNOLOGY & ENGINEERING
Languages : en
Pages : 107

Book Description
"Provides information on liquid cooling for datacom equipment centers. Concerned with energy efficiency"--

Air Flow Management in Raised Floor Data Centers

Air Flow Management in Raised Floor Data Centers PDF Author: Vaibhav K. Arghode
Publisher: Springer
ISBN: 3319258923
Category : Business & Economics
Languages : en
Pages : 90

Book Description
The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers.

Energy Efficient Thermal Management of Data Centers

Energy Efficient Thermal Management of Data Centers PDF Author: Yogendra Joshi
Publisher: Springer Science & Business Media
ISBN: 1441971238
Category : Science
Languages : en
Pages : 635

Book Description
Energy Efficient Thermal Management of Data Centers examines energy flow in today's data centers. Particular focus is given to the state-of-the-art thermal management and thermal design approaches now being implemented across the multiple length scales involved. The impact of future trends in information technology hardware, and emerging software paradigms such as cloud computing and virtualization, on thermal management are also addressed. The book explores computational and experimental characterization approaches for determining temperature and air flow patterns within data centers. Thermodynamic analyses using the second law to improve energy efficiency are introduced and used in proposing improvements in cooling methodologies. Reduced-order modeling and robust multi-objective design of next generation data centers are discussed.

Best Practices for Datacom Facility Energy Efficiency

Best Practices for Datacom Facility Energy Efficiency PDF Author:
Publisher: American Society of Heating Refrigerating and Air-Conditioning Engineers
ISBN: 9781933742472
Category : Buildings
Languages : en
Pages : 0

Book Description
Sustainable design, global warming, depleting fuel reserves, energy use, and operating cost are becoming increasingly more important. These issues are even more important in datacom equipment centers for reasons such as: Large, concentrated use of energy (can be 100 times the watts per square foot of an office building). 24/7 operations have about three times the annual operating hours as other commercial properties. The intent of this publication is to provide the reader with detailed information on the design of datacom facilities that will aid in minimizing the life-cycle cost to the client and to maximize energy efficiency in a facility to align with ASHRAE's stated direction to lead the advancement of sustainable building design and operations.This book covers many aspects of datacom facility energy efficiency, including chapters on the topics of environmental criteria, mechanical equipment and systems, economizer cycles, airflow distribution, HVAC controls and energy management, electrical distribution equipment, datacom equipment efficiency, liquid cooling, total cost of ownership, and emerging technologies. There are also appendices on such topics as facility commissioning, operations and maintenance, and telecom facility experiences. The primary changes for this second edition center on the updated environmental envelope and relate to the recommended temperatures at the inlets of the equipment operating in datacom facilities. This book is the sixth in the ASHRAE Datacom Series, authored by ASHRAE Technical Committee 9.9, Mission Critical Facilities, Technology Spaces and Electronic Equipment. This series provides comprehensive treatment of datacom cooling and related subjects.

Design Considerations for Datacom Equipment Centers

Design Considerations for Datacom Equipment Centers PDF Author: American Society of Heating, Refrigerating and Air-Conditioning Engineers
Publisher: American Society of Heating Refrigerating and Air-Conditioning Engineers
ISBN: 9781933742489
Category : Technology & Engineering
Languages : en
Pages : 210

Book Description
The design of computer rooms and telecommunications facilities is different in fundamental ways from the design of facilities used primarily for human occupancy. ASHRAE has not, until now, published a basic reference text to provide an overview of the special design needs of datacom facilities. As the power density of datacom equipment continues to increase, this need has grown more severe. This book covers basic design considerations for data and communications equipment centers. The book is divided into two parts. Part I, Datacom Facility Basics, includes chapters on datacom design criteria (temperature, temperature rate of change, relative humidity, dew point, and filtration), HVAC load, computer room cooling (including both air and liquid cooling), and air distribution. Part II of the book, Other Considerations, includes chapters on ancillary spaces (battery plants, emergency generator rooms, burn-in rooms and test labs, and spare parts rooms), contamination, acoustical noise emissions, structural and seismic design and testing, fire detection and suppression, commissioning, availability and redundancy, and energy efficiency. This book does not cover electrical or electronic systems design and distribution. The primary changes for this second edition center on the updated thermal envelope and relate to the recommended temperatures at the inlets of the equipment operating in datacom facilities. This book is the third in the ASHRAE Datacom Series, authored by ASHRAE Technical Committee 9.9, Mission Critical Facilities, Technology Spaces and Electronic Equipment. This series provides comprehensive treatment of datacom cooling and related subjects.