Author: R. H. Basappa Setty
Publisher:
ISBN:
Category : Columns, Concrete
Languages : en
Pages : 130
Book Description
The research work involved a study of behaviour and strength of eccentrically loaded High Strength Concrete columns. The research comprised experimental and analytical components. With regard to experimental work, twelve columns were manufactured and tested to failure. All columns were rectangular in cross-section with 300 mm x 100 mm as dimensions. The test specimens were loaded about the minor axis. The ratio of longitudinal reinforcement was either 1.47% (4 - 12 mm diameter bars) or 2.2% (6 - 12 mm diameter bars). The lateral reinforcement was in the form of rectangular closed ties made of 6 mm wires (W6). The spacing of ties was generally 50 mm, but, was decreased to 30 mm, at either ends to avoid premature failure.