MGA++ Analysis of Low Quantity Samples of U and Pu on an Extended-rage Gamma-ray Detector PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download MGA++ Analysis of Low Quantity Samples of U and Pu on an Extended-rage Gamma-ray Detector PDF full book. Access full book title MGA++ Analysis of Low Quantity Samples of U and Pu on an Extended-rage Gamma-ray Detector by . Download full books in PDF and EPUB format.

MGA++ Analysis of Low Quantity Samples of U and Pu on an Extended-rage Gamma-ray Detector

MGA++ Analysis of Low Quantity Samples of U and Pu on an Extended-rage Gamma-ray Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 8

Book Description
The IAEA has expressed a need for improved determination of gamma emitting nuclides in environmental samples collected during inspections of nuclear facilities and to use the MGA++ to determine U and Pu concentrations and isotopic compositions when those elements are present in relatively high concentrations. We are addressing the IAEA needs by evaluating the applicability of extended-range germanium detectors (ERG). In this paper we used 1g U isotopic standards and 100ug Pu liquid standards (1) to determine the performance of MGA++ on this special detector and (2) to estimate the amount of U and Pu necessary in the sample for determination of the isotopics via MGA++ within reasonable accuracy for a week of counting time using this ERG detector.

MGA++ Analysis of Low Quantity Samples of U and Pu on an Extended-rage Gamma-ray Detector

MGA++ Analysis of Low Quantity Samples of U and Pu on an Extended-rage Gamma-ray Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 8

Book Description
The IAEA has expressed a need for improved determination of gamma emitting nuclides in environmental samples collected during inspections of nuclear facilities and to use the MGA++ to determine U and Pu concentrations and isotopic compositions when those elements are present in relatively high concentrations. We are addressing the IAEA needs by evaluating the applicability of extended-range germanium detectors (ERG). In this paper we used 1g U isotopic standards and 100ug Pu liquid standards (1) to determine the performance of MGA++ on this special detector and (2) to estimate the amount of U and Pu necessary in the sample for determination of the isotopics via MGA++ within reasonable accuracy for a week of counting time using this ERG detector.

High-resolution Gamma-ray Isotopic Measurements of Uranium Plutonium Samples at IPPE in Support of Physical Inventory Taking Activities

High-resolution Gamma-ray Isotopic Measurements of Uranium Plutonium Samples at IPPE in Support of Physical Inventory Taking Activities PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Measurement of various U and Pu samples by gamma-ray spectrometry were performed at the Institute of Physics and Power Engineering to support physical-inventory-taking activities under the Joint US-Russian MPC and A Program. The resulting data was analyzed by several different methods which included Canberra's MGA9.63 (Pu and MOX analysis) and MGAU (U analysis), EG and G Ortec's MGA++ (Pu and MOX analysis) and U235 (U analysis), and FRAM v2.2 (U and Pu analysis) provided by Los Alamos. The results indicate that all of these codes are capable of performing the isotopic analysis adequately. However, some additional modifications may be required to permit better measurement of some of the more unusual components in the Institute of Physics and Power Engineering (IPPE) inventory to meet the demands of inventory-taking activities.

Multiple Group Analysis (MGA)

Multiple Group Analysis (MGA) PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
MGA calculates relative isotopic abundances of plutonium and other actinides in a sample. The code performs its analysis using data from a gamma-ray spectrum of the sample taken with a germanium detector. This volume describes the structure of the program and the procedures used for measuring samples and analyzing the spectra. It is assumed that the user is familiar with standard practices and equipment used in gamma-ray spectrometry.

Full Range MGA Plutonium Isotopic Analysis Using Single Ge Detector

Full Range MGA Plutonium Isotopic Analysis Using Single Ge Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
The Gamma-Ray multi-group analysis code MGA developed at Lawrence Livermore National Laboratory has been widely used in the area of gamma-ray non-destructive plutonium assay. This plutonium isotopic analysis code de-convolutes the complicated, 100-keV x-ray and gamma-ray region to obtain the ratio of Pu isotopes. Calibration of the detector efficiency is not required, but is determined intrinsically from the measured spectra. The code can either analyze low-energy gamma-ray spectrum taken using a high-resolution HPGe detector for energies below 300 keV, or analyze the low-energy spectrum combined with a high-energy spectrum (up to 1 MeV) in the two-detector analysis mode. In the latter case, the use of two detectors has been mandated by the conflicting requirements: excellent resolution at low energies (characteristic of small planar detectors) with good high-energy efficiency (characteristic of coaxial detectors). Usually, a high-energy spectrum taken using a coaxial Ge detector will not provide sufficient energy resolution for 100-keV plutonium isotopic analysis, while the small planar used at low energies has inadequate high-energy efficiency. An optimized-geometry ORTEC HPGe detector has been developed which combines good energy resolution at 100 keV combined with acceptable high-energy ((almost equal to) 1 MeV) efficiency in a single detector. It has been used to gather spectra of both low- and high-energy regions of plutonium spectra simultaneously, for analysis by MGA in the two-detector mode. Five Pu gamma-ray calibration standard sources were used in this study of this special detector.

Handbook of Nuclear Chemistry

Handbook of Nuclear Chemistry PDF Author: Attila Vértes
Publisher: Springer Science & Business Media
ISBN: 144190719X
Category : Science
Languages : en
Pages : 3693

Book Description
This revised and extended 6 volume handbook set is the most comprehensive and voluminous reference work of its kind in the field of nuclear chemistry. The Handbook set covers all of the chemical aspects of nuclear science starting from the physical basics and including such diverse areas as the chemistry of transactinides and exotic atoms as well as radioactive waste management and radiopharmaceutical chemistry relevant to nuclear medicine. The nuclear methods of the investigation of chemical structure also receive ample space and attention. The international team of authors consists of scores of world-renowned experts - nuclear chemists, radiopharmaceutical chemists and physicists - from Europe, USA, and Asia. The Handbook set is an invaluable reference for nuclear scientists, biologists, chemists, physicists, physicians practicing nuclear medicine, graduate students and teachers - virtually all who are involved in the chemical and radiopharmaceutical aspects of nuclear science. The Handbook set also provides further reading via the rich selection of references.

MGA

MGA PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 99

Book Description
Nondestructive measurements of x-ray and gamma-ray emissions can be used to determine the abundances of various actinides in a sample. Volume 1 of this report describes the methods and algorithms we have developed to determine the relative isotopic abundances of actinides in a sample, by analyzing gamma-ray spectra obtained using germanium detector systems. Volume 2 is a guide to using the MGA (Multiple Group Analysis) computer program we have written to perform plutonium isotopic analyses. This report contains a listing of the FORTRAN instructions of the code.

MGA and Passive Neutron Measurements

MGA and Passive Neutron Measurements PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 9

Book Description
MGA is a gamma-ray spectrum analysis program for determining relative plutonium isotopic abundances. The isotopic composition of a plutonium sample is needed to calculate 24°Pu{sub eff} that is used to interpret passive neutron coincidence measurements in units of absolute plutonium mass. MGA can determine plutonium isotopic abundances with accuracies better than 1% using a high-resolution, low-energy, planar germanium detector and measurement times ten minutes or less. MGA can include analysis of a second spectrum of the high-energy (300--600 keV) plutonium gamma rays that significantly improves the determination of 24°P{sub eff} in high-burnup plutonium. For the high-energy gamma-ray measurements we have devised a new hardware configuration, so that both the low- and high-energy gamma-ray detectors are mounted in a single cryostat thereby reducing weight and volume of the detector systems. We describe the detector configuration and our experience with it using a combined neutron-gamma measurement system and the two-detector version of MGA. We discuss the sources of uncertainty in the determination of 24°Pu{sub eff} and propose a new correlation for the determination of 242Pu.

MGA++ Studies of U/Pu Gamma-ray Standards with Two Falcon 5000 Mechanical Cooled HPGe Detection Systems

MGA++ Studies of U/Pu Gamma-ray Standards with Two Falcon 5000 Mechanical Cooled HPGe Detection Systems PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Book Description


MGA (Multi-Group Analysis)

MGA (Multi-Group Analysis) PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 41

Book Description
Nondestructive measurements of x-ray and gamma-ray emissions can be used to analyze a sample for plutonium. This report describes the methods and algorithms we have developed for analyzing gamma-ray spectra obtained by using a germanium detector system to accurately determine the relative abundances of various actinide isotopes in a sample. Our methodology requires no calibrations and can be used to measure virtually any size and type of plutonium sample. Measurement times can be as short as a few minutes; measurements are frequently accurate to within 1%. Our methods have been programmed into a computerized analysis code called MGA (Multi-Group Analysis). Our current versions can be run on personal computers (IBM type) and on the DEC VAX microcomputer. Spectral analysis times are usually far less than a minute. 28 refs., 26 figs., 1 tab.

Gamma-ray Analysis of Atmospheric Dust Samples

Gamma-ray Analysis of Atmospheric Dust Samples PDF Author: J. L. Horwood
Publisher: Queen's Printer
ISBN:
Category : Cosmic dust
Languages : en
Pages : 28

Book Description