Mechanical Properties and Structure of Ti-6Al-4V with Graded-Porosity Coatings Applied by Plasma Spraying for Use in Orthopedic Implants PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Mechanical Properties and Structure of Ti-6Al-4V with Graded-Porosity Coatings Applied by Plasma Spraying for Use in Orthopedic Implants PDF full book. Access full book title Mechanical Properties and Structure of Ti-6Al-4V with Graded-Porosity Coatings Applied by Plasma Spraying for Use in Orthopedic Implants by AC. Fraker. Download full books in PDF and EPUB format.

Mechanical Properties and Structure of Ti-6Al-4V with Graded-Porosity Coatings Applied by Plasma Spraying for Use in Orthopedic Implants

Mechanical Properties and Structure of Ti-6Al-4V with Graded-Porosity Coatings Applied by Plasma Spraying for Use in Orthopedic Implants PDF Author: AC. Fraker
Publisher:
ISBN:
Category : Biodegradation
Languages : en
Pages : 13

Book Description
The object of this work was to determine mechanical properties of implants with graded porous coatings without reference to the properties of the ingrown bone. Optimum strength of a bone/implant interface consisting of porous metal and ingrown bone requires a gradation from base metal to the original bone. The composite metal-bone interface can be obtained by applying a metal coating of graded porosity, varying from near zero at the substrate surface to more than 50% at the outermost layer, on the original implant. Graded porous coatings of titanium or Ti-6Al-4V were obtained by plasma spraying of selected particle size fractions in three layers of successively decreasing density, the top coat being made with 300 to 850 ?m powder. Tensile and shear strengths of the coatings were determined by cementing coated samples face to face with an adhesive resin to simulate ingrown bone. Data from these tests are given. Shear strength values ranged from 5.6 to 9.9 MPa (815 to 1430 psi) and tensile strength values were 5.1 to 25.5 MPa (745 to 3700 psi). Failure occurred within the porous coating and not at the interface between the substrate and the coating. Corrosion fatigue tests in Hanks' solution at 37°C (98.6°F) and a pH of 7.4, with a cyclic, fully reversed, peak torsional shear strain of ±0.01, gave lifetimes comparable to or better than those reported for mill-annealed Ti-6Al-4V, except for the samples that had been sintered.

Mechanical Properties and Structure of Ti-6Al-4V with Graded-Porosity Coatings Applied by Plasma Spraying for Use in Orthopedic Implants

Mechanical Properties and Structure of Ti-6Al-4V with Graded-Porosity Coatings Applied by Plasma Spraying for Use in Orthopedic Implants PDF Author: AC. Fraker
Publisher:
ISBN:
Category : Biodegradation
Languages : en
Pages : 13

Book Description
The object of this work was to determine mechanical properties of implants with graded porous coatings without reference to the properties of the ingrown bone. Optimum strength of a bone/implant interface consisting of porous metal and ingrown bone requires a gradation from base metal to the original bone. The composite metal-bone interface can be obtained by applying a metal coating of graded porosity, varying from near zero at the substrate surface to more than 50% at the outermost layer, on the original implant. Graded porous coatings of titanium or Ti-6Al-4V were obtained by plasma spraying of selected particle size fractions in three layers of successively decreasing density, the top coat being made with 300 to 850 ?m powder. Tensile and shear strengths of the coatings were determined by cementing coated samples face to face with an adhesive resin to simulate ingrown bone. Data from these tests are given. Shear strength values ranged from 5.6 to 9.9 MPa (815 to 1430 psi) and tensile strength values were 5.1 to 25.5 MPa (745 to 3700 psi). Failure occurred within the porous coating and not at the interface between the substrate and the coating. Corrosion fatigue tests in Hanks' solution at 37°C (98.6°F) and a pH of 7.4, with a cyclic, fully reversed, peak torsional shear strain of ±0.01, gave lifetimes comparable to or better than those reported for mill-annealed Ti-6Al-4V, except for the samples that had been sintered.

Medical Applications of Titanium and Its Alloys

Medical Applications of Titanium and Its Alloys PDF Author: Jack E. Lemons
Publisher: ASTM International
ISBN: 0803120109
Category : Biomedical Technology
Languages : en
Pages : 422

Book Description
Thirty papers presented at a 1994 symposium cover the basic materials science issues regarding the processing of titanium alloys, and the controversy regarding their use in medicine. Coverage includes orthopaedic, dental, and cardiovascular applications, with a primary focus on the orthopaedic. Info

Publications of the National Institute of Standards and Technology ... Catalog

Publications of the National Institute of Standards and Technology ... Catalog PDF Author: National Institute of Standards and Technology (U.S.)
Publisher:
ISBN:
Category :
Languages : en
Pages : 398

Book Description


Publications of the National Bureau of Standards, 1986 Catalog

Publications of the National Bureau of Standards, 1986 Catalog PDF Author: United States. National Bureau of Standards
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 420

Book Description


Publications of the National Bureau of Standards ... Catalog

Publications of the National Bureau of Standards ... Catalog PDF Author: United States. National Bureau of Standards
Publisher:
ISBN:
Category :
Languages : en
Pages : 396

Book Description


Publications

Publications PDF Author: United States. National Bureau of Standards
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 402

Book Description


Handbook Of Biomaterials Evaluation

Handbook Of Biomaterials Evaluation PDF Author: Andreas F von Recum
Publisher: CRC Press
ISBN: 9781560324799
Category : Medical
Languages : en
Pages : 944

Book Description
This handbook addresses the needs of those who are involved in inventing, developing, and testing implants and are concerned about the interactions between biomaterial and body tissue. The authors explore the physical, chemical, mechanical and regulatory considerations of synthetic materials used in surgical and implant procedures, and how these factors impact the latest developments and new approaches. This updated edition provides the biomaterials professional with necessary information on a range of issues, including bulk characterization, surface evaluations, toxicological evaluations, in vitro methods for safety evaluation, methods for evaluating materials in special applications, surgical considerations, systems implantology, soft and hard tissue history, regulatory aspects, and clinical trials.

Characterization and Performance of Calcium Phosphate Coatings for Implants

Characterization and Performance of Calcium Phosphate Coatings for Implants PDF Author: Emanuel Horowitz
Publisher: ASTM International
ISBN: 0803118546
Category : Biocompatible Materials
Languages : en
Pages : 222

Book Description


Biocompatibility of Surgical and Dental Implant Materials

Biocompatibility of Surgical and Dental Implant Materials PDF Author:
Publisher:
ISBN:
Category : Biomedical materials
Languages : en
Pages : 160

Book Description


Thermal Spray Research and Applications

Thermal Spray Research and Applications PDF Author: Thomas F. Bernecki
Publisher: ASM International(OH)
ISBN:
Category : Technology & Engineering
Languages : en
Pages : 816

Book Description
Proceedings of the Third National Thermal Spray Conference held May 1990, Long Beach, Calif. Over 100 papers detail coating solutions to wear, corrosion, and thermal environment problems, addressing various aspects of processing science, abradables, wear/erosion, corrosion, surface treatment post-sp