Author: Donald P. Alexander
Publisher:
ISBN:
Category : Air conditioning
Languages : en
Pages :
Book Description
Georgia Institute of Technology Chilled Water System Evaluation and Master Plan
Author: Donald P. Alexander
Publisher:
ISBN:
Category : Air conditioning
Languages : en
Pages :
Book Description
Publisher:
ISBN:
Category : Air conditioning
Languages : en
Pages :
Book Description
Georgia Institute of Technology Chilled Water System Evaluation and Master Plan
Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 164
Book Description
As the host of the Olympic Village for the 1996 Atlanta Olympics, Georgia Tech has experienced a surge in construction activities over the last three years. Over 1.3 million square feet of new buildings have been constructed on the Georgia Tech campus. This growth has placed a strain on the Georgia Tech community and challenged the facilities support staff charged with planning and organizing utility services. In concert with Olympic construction, utility planners have worked to ensure long term benefits for Georgia Tech facilities while meeting the short term requirements of the Olympic Games. The concentration of building construction in the northwest quadrant of the campus allowed planners to construct a satellite chilled water plant to serve the needs of this area and provide the opportunity to integrate this section of the campus with the main campus chilled water system. This assessment and master plan, funded in part by the US Department of Energy, has evaluated the chilled water infrastructure at Georgia Tech, identified ongoing problems and made recommendations for long term chilled water infrastructure development and efficiency improvements. The Georgia Tech office of Facilities and RDA Engineering, Inc. have worked together to assemble relevant information and prepare the recommendations contained in this document.
Publisher:
ISBN:
Category :
Languages : en
Pages : 164
Book Description
As the host of the Olympic Village for the 1996 Atlanta Olympics, Georgia Tech has experienced a surge in construction activities over the last three years. Over 1.3 million square feet of new buildings have been constructed on the Georgia Tech campus. This growth has placed a strain on the Georgia Tech community and challenged the facilities support staff charged with planning and organizing utility services. In concert with Olympic construction, utility planners have worked to ensure long term benefits for Georgia Tech facilities while meeting the short term requirements of the Olympic Games. The concentration of building construction in the northwest quadrant of the campus allowed planners to construct a satellite chilled water plant to serve the needs of this area and provide the opportunity to integrate this section of the campus with the main campus chilled water system. This assessment and master plan, funded in part by the US Department of Energy, has evaluated the chilled water infrastructure at Georgia Tech, identified ongoing problems and made recommendations for long term chilled water infrastructure development and efficiency improvements. The Georgia Tech office of Facilities and RDA Engineering, Inc. have worked together to assemble relevant information and prepare the recommendations contained in this document.
Modeling and Analysis of Chilled Water Systems
Author: Shawn Eric Klawunder
Publisher:
ISBN:
Category : Cooling towers
Languages : en
Pages : 310
Book Description
Publisher:
ISBN:
Category : Cooling towers
Languages : en
Pages : 310
Book Description
Oregon Institute of Technology Chilled Water System Evaluation
Author: Systems West Engineers
Publisher:
ISBN:
Category : Air conditioning from central stations
Languages : en
Pages :
Book Description
Systems West Engineers was retained by the Oregon Institute of Technology to evaluate the central chilled water system and develop recommendations for chiller plant upgrade including replacement of existing chillers. Section 1 includes a brief summary of recommended modifications and a project cost summary. More detailed information is contained in following sections including a system description, chilled water system evaluation, and recommendations.
Publisher:
ISBN:
Category : Air conditioning from central stations
Languages : en
Pages :
Book Description
Systems West Engineers was retained by the Oregon Institute of Technology to evaluate the central chilled water system and develop recommendations for chiller plant upgrade including replacement of existing chillers. Section 1 includes a brief summary of recommended modifications and a project cost summary. More detailed information is contained in following sections including a system description, chilled water system evaluation, and recommendations.
Federal Register
ERDA.
Project Data Summaries
Author: Systems Consultants, inc
Publisher:
ISBN:
Category : Solar energy
Languages : en
Pages : 132
Book Description
Publisher:
ISBN:
Category : Solar energy
Languages : en
Pages : 132
Book Description
National Program for Solar Heating and Cooling of Buildings
Monthly Catalog of United States Government Publications
Author: United States. Superintendent of Documents
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1256
Book Description
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1256
Book Description