ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK. PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK. PDF full book. Access full book title ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK. by . Download full books in PDF and EPUB format.

ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK.

ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 13

Book Description
OAK A271 ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK. The electron cyclotron emission (ECE) heterodyne radiometer diagnostic on DIII-D has been upgraded with the addition of eight channels for a total of 40. The new, higher frequency channels allow measurements of electron temperature into the magnetic axis in discharges at maximum field, 2.15 T. The complete set now extends over the full usable range of second harmonic emission frequencies at 2.0 T covering radii from the outer edge inward to the location of third harmonic overlap on the high field side. Full coverage permits the measurement of heat pulses and magnetohydrodynamic (MHD) fluctuations on both sides of the magnetic axis. In addition, the symmetric measurements are used to fix the location of the magnetic axis in tokamak magnetic equilibrium reconstructions. Also, the new higher frequency channels have been used to determine central T{sub e} with good time resolution in low field, high density discharges using third harmonic ECE in the optically gray and optically thick regimes.

ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK.

ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 13

Book Description
OAK A271 ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK. The electron cyclotron emission (ECE) heterodyne radiometer diagnostic on DIII-D has been upgraded with the addition of eight channels for a total of 40. The new, higher frequency channels allow measurements of electron temperature into the magnetic axis in discharges at maximum field, 2.15 T. The complete set now extends over the full usable range of second harmonic emission frequencies at 2.0 T covering radii from the outer edge inward to the location of third harmonic overlap on the high field side. Full coverage permits the measurement of heat pulses and magnetohydrodynamic (MHD) fluctuations on both sides of the magnetic axis. In addition, the symmetric measurements are used to fix the location of the magnetic axis in tokamak magnetic equilibrium reconstructions. Also, the new higher frequency channels have been used to determine central T{sub e} with good time resolution in low field, high density discharges using third harmonic ECE in the optically gray and optically thick regimes.

High Spatial Resolution Upgrade of the Electron Cyclotron Emission Radiometer for the DIII-D Tokamak

High Spatial Resolution Upgrade of the Electron Cyclotron Emission Radiometer for the DIII-D Tokamak PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
The 40-channel DIII-D electron cyclotron emission (ECE) radiometer provides measurements of Te(r, t) at the tokamak midplane from optically thick, second harmonic X-mode emission over a frequency range of 83-130 GHz. Heterodyning divides this frequency range into three 2-18 GHz intermediate frequency (IF) bands. The frequency spacing of the radiometer's channels results in a spatial resolution of ~1-3 cm, depending on local magnetic field and electron temperature. A new high resolution subsystem has been added to the DIII-D ECE radiometer to make sub-centimeter (0.6-0.8 cm) resolution Te measurements. The high resolution subsystem branches off from the regular channels' IF bands and consists of a microwave switch to toggle between IF bands, a switched filter bank for frequency selectivity, an adjustable local oscillator and mixer for further frequency down-conversion, and a set of eight microwave filters in the 2-4 GHz range. We achieved a higher spatial resolution through the use of a narrower (200 MHz) filter bandwidth and closer spacing between the filters' center frequencies (250 MHz). This configuration allows for full coverage of the 83-130 GHz frequency range in 2 GHz bands. Depending on the local magnetic field, this translates into a "zoomed-in" analysis of a ~2-4 cm radial region. These high resolution channels will be most useful in the low-field side edge region where modest Te values (1-2 keV) result in a minimum of relativistic broadening. Some expected uses of these channels include mapping the spatial dependence of Alfven eigenmodes, geodesic acoustic modes, and externally applied magnetic perturbations. Initial Te measurements, which demonstrate that the desired resolution is achieved, is presented.

Issues in Applied, Analytical, and Imaging Sciences Research: 2013 Edition

Issues in Applied, Analytical, and Imaging Sciences Research: 2013 Edition PDF Author:
Publisher: ScholarlyEditions
ISBN: 1490108580
Category : Science
Languages : en
Pages : 1173

Book Description
Issues in Applied, Analytical, and Imaging Sciences Research: 2013 Edition is a ScholarlyEditions™ book that delivers timely, authoritative, and comprehensive information about Applied Analysis. The editors have built Issues in Applied, Analytical, and Imaging Sciences Research: 2013 Edition on the vast information databases of ScholarlyNews.™ You can expect the information about Applied Analysis in this book to be deeper than what you can access anywhere else, as well as consistently reliable, authoritative, informed, and relevant. The content of Issues in Applied, Analytical, and Imaging Sciences Research: 2013 Edition has been produced by the world’s leading scientists, engineers, analysts, research institutions, and companies. All of the content is from peer-reviewed sources, and all of it is written, assembled, and edited by the editors at ScholarlyEditions™ and available exclusively from us. You now have a source you can cite with authority, confidence, and credibility. More information is available at http://www.ScholarlyEditions.com/.

Fusion Energy Update

Fusion Energy Update PDF Author:
Publisher:
ISBN:
Category : Controlled fusion
Languages : en
Pages : 614

Book Description


Government Reports Announcements & Index

Government Reports Announcements & Index PDF Author:
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 1132

Book Description


An Upgrade of the Magnetic Diagnostic System of the DIII-D Tokamak for Non-axisymmetric Measurements

An Upgrade of the Magnetic Diagnostic System of the DIII-D Tokamak for Non-axisymmetric Measurements PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Here, the DIII-D tokamak magnetic diagnostic system has been upgraded to significantly expand the measurement of the plasma response to intrinsic and applied non-axisymmetric "3D" fields. The placement and design of 101 additional sensors allow resolution of toroidal mode numbers 1 ≤ n ≤ 3, and poloidal wavelengths smaller than MARS-F, IPEC, and VMEC magnetohydrodynamic (MHD) model predictions. Small 3D perturbations, relative to the equilibrium field (10-5

Energy Research Abstracts

Energy Research Abstracts PDF Author:
Publisher:
ISBN:
Category : Power resources
Languages : en
Pages : 782

Book Description


Ec-9: Proceedings Of The Ninth Joint Workshop On Electron Cyclotron Emission And Electron Cyclotron Heating

Ec-9: Proceedings Of The Ninth Joint Workshop On Electron Cyclotron Emission And Electron Cyclotron Heating PDF Author: John Lohr
Publisher: World Scientific
ISBN: 9814548979
Category :
Languages : en
Pages : 678

Book Description
The conference proceedings will include the papers of approximately 50 key specialists from most of the world's major fusion laboratories, including the European Community, the U.S., Russia and the PRC. The unifying themes are the emission of electron cyclotron waves by high temperature plasmas and the reciprocal process, absorption, which can be used for heating, non inductive current drive and diagnostic purposes.

Studies of Turbulence and Flows in the DIII-D Tokamak

Studies of Turbulence and Flows in the DIII-D Tokamak PDF Author: Jon Clark Hillesheim
Publisher:
ISBN:
Category :
Languages : en
Pages : 307

Book Description
Understanding the turbulent transport of particles, momentum, and heat continues to be an important goal for magnetic confinement fusion energy research. The turbulence in tokamaks and other magnetic confinement devices is widely thought to arise due to linearly unstable gyroradius-scale modes. A long predicted characteristic of these linear instabilities is a critical gradient, where the modes are stable below a critical value related to the gradient providing free energy for the instability and unstable above it. In this dissertation, a critical gradient threshold for long wavelength ($k_{\theta} \rho_s \lesssim 0.4$) electron temperature fluctuations is reported, where the temperature fluctuations do not change, within uncertainties, below a threshold value in $L_{T_e}^{-1}=\nabla T_e / T_e$ and steadily increase above it. This principal result, the direct observation of a critical gradient for electron temperature fluctuations, is also the first observation of critical gradient behavior for \textit{any} locally measured turbulent quantity in the core of a high temperature plasma in a systematic experiment. The critical gradient was found to be $L_{T_e}^{-1}_{crit}=2.8 \pm 0.4 \ \mathrm{m}^{-1}$. The experimental value for the critical gradient quantitatively disagrees with analytical predictions for its value. In the experiment, the local value of $L_{T_e}^{-1}$ was systematically varied by changing the deposition location of electron cyclotron heating gyrotrons in the DIII-D tokamak. The temperature fluctuation measurements were acquired with a correlation electron cyclotron emission radiometer. The dimensionless parameter $\eta_e=L_{n_e}/L_{T_e}$ is found to describe both the temperature fluctuation threshold and a threshold observed in linear gyrofluid growth rate calculations over the measured wave numbers, where a rapid increase at $\eta_e \approx 2$ is observed in both. Doppler backscattering (DBS) measurements of intermediate-scale density fluctuations also show a frequency-localized increase on the electron diamagnetic side of the measured spectrum that increases with $L_{T_e}^{-1}$. Measurements of the crossphase angle between long wavelength electron density and temperature fluctuations, as well as measurements of long wavelength density fluctuation levels were also acquired. Multiple aspects of the fluctuation measurements and calculations are individually consistent with the attribution of the critical gradient to the $\nabla T_e$-driven trapped electron mode. The accumulated evidence strongly enforces this conclusion. The threshold value for the temperature fluctuation measurements was also within uncertainties of a critical gradient for the electron thermal diffusivity found through heat pulse analysis, above which the electron heat flux and electron temperature profile stiffness rapidly increased. Toroidal rotation was also systematically varied with neutral beam injection, which had little effect on the temperature fluctuation measurements. The crossphase measurements indicated the presence of different instabilities below the critical gradient depending on the neutral beam configuration, which is supported by linear gyrofluid calculations. In a second set of results reported in this dissertation, the geodesic acoustic mode is investigated in detail. Geodesic acoustic modes (GAMs) and zonal flows are nonlinearly driven, axisymmetric ($m=0,\ n=0$ potential) $E \times B$ flows, which are thought to play an important role in establishing the saturated level of turbulence in tokamaks. Zonal flows are linearly stable, but are driven to finite amplitude through nonlinear interaction with the turbulence. They are then thought to either shear apart the turbulent eddies or act as a catalyst to transfer energy to damped modes. Results are presented showing the GAM's observed spatial scales, temporal scales, and nonlinear interaction characteristics, which may have implications for the assumptions underpinning turbulence models towards the tokamak edge ($r/a \gtrsim 0.75$). Measurements in the DIII-D tokamak have been made with multichannel Doppler backscattering systems at toroidal locations separated by $180^{\circ}$; analysis reveals that the GAM is highly coherent between the toroidally separated systems ($\gamma> 0.8$) and that measurements are consistent with the expected $m=0,\ n=0$ structure. Observations show that the GAM in L-mode plasmas with $\sim 2.5-4.5$ MW auxiliary heating occurs as a radially coherent eigenmode, rather than as a continuum of frequencies as occurs in lower temperature discharges; this is consistent with theoretical expectations when finite ion Larmor radius effects are included. The intermittency of the GAM has been quantified, revealing that its autocorrelation time is fairly short, ranging from about 4 to about 15 GAM periods in cases examined, a difference that is accompanied by a modification to the probability distribution function of the $E \times B$ velocity at the GAM frequency. Conditionally-averaged bispectral analysis shows the strength of the nonlinear interaction of the GAM with broadband turbulence can vary with the magnitude of the GAM. Data also indicates a wave number dependence to the GAM's interaction with turbulence. Measurements also showed the existence of additional low frequency zonal flows (LFZF) at a few kilohertz in the core of DIII-D plasmas. These LFZF also correlated toroidally. The amplitude of both the GAM and LFZF were observed to depend on toroidal rotation, with both types of flows barely detectable in counter-injected plasmas. In a third set of results the development of diagnostic hardware, techniques used to acquire the above data, and related work is described. A novel multichannel Doppler backscattering system was developed. The five channel system operates in V-band (50-75 GHz) and has an array of 5 frequencies, separated by 350 MHz, which is tunable as a group. Laboratory tests of the hardware are presented. Doppler backscattering is a diagnostic technique for the radially localized measurement of intermediate-scale ($k_{\theta} \rho_s \sim 1$) density fluctuations and the laboratory frame propagation velocity of turbulent structures. Ray tracing, with experimental profiles and equilibria for inputs, is used to determine the scattering wave number and location. Full wave modeling, also with experimental inputs, is used for a synthetic Doppler backscattering diagnostic for nonlinear turbulence simulations. A number of non-ideal processes for DBS are also investigated; their impact on measurements in DIII-D are found, for the most part, to be small.

Hardware and Software Upgrades to DIII-D Main Computer Control System

Hardware and Software Upgrades to DIII-D Main Computer Control System PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 14

Book Description
The complexities of monitoring and controlling the various DIII-D tokamak systems have always required the aid of high-speed computer resources. Because of recent improvements in computing technology, DIII-D has upgraded both hardware and software for the central DIII-D control system. This system is responsible for coordination of all main DIII-D subsystems during a plasma discharge. The replacement of antiquated older hardware has increased reliability and reduced costs both in the initial procurement and eventual maintenance of the system. As expected, upgrading the corresponding computer software has become the more time consuming and expensive part of this upgrade. During this redesign, the main issues focused on making the most of existing in-house codes, speed with which the new system could be brought on-line, the ability to add new features/enhancements, ease of integration with all DIII-D systems and future portability/upgrades. The resulting system has become a template by which other DIII-D systems can follow during similar upgrade paths; in particular DIII-D's main data acquisition system and neutral beam injection (NBI).