Author:
Publisher:
ISBN:
Category : Electric circuit-breakers
Languages : en
Pages :
Book Description
C37.20.1b-2006 IEEE Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear Amendment 2: Additional Requirements for Control and Auxiliary Power Wiring in DC Traction Power Switchgear
IEEE Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear Amendment 1
IEEE Standard for Metal-enclosed Low-voltage Power Circuit Breaker Switchgear
Author:
Publisher:
ISBN: 9780738133034
Category : Electric circuit-breakers
Languages : en
Pages : 55
Book Description
Abstract: Low-voltage metal-enclosed switchgear-which contains either stationary or drawout, manually or electrically operated low-voltage ac or dc power circuit breakers in individual grounded metal compartments, in three-pole, two-pole, or single-pole construction-is covered. Rated maximum voltage levels are 254 V, 508 V, or 635 V (ac) and 300/325 V, 800 V, 1000 V, 1200 V, 1600 V, or 3200 V (dc). The preferred continuous current ratings of the main bus in ac designs are 1600 A, 2000 A, 3000 A, 3200 A, 4000 A, or 5000 A. For dc designs, the preferred ratings are 1600 A, 2000 A, 2500 A, 3000 A, 4000 A, 5000 A, 6000 A, 8000 A, 10 000 A, or 12 000 A. The switchgear may also contain associated control, instruments, metering, protective, and regulating devices as necessary. The standard deals with service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.
Publisher:
ISBN: 9780738133034
Category : Electric circuit-breakers
Languages : en
Pages : 55
Book Description
Abstract: Low-voltage metal-enclosed switchgear-which contains either stationary or drawout, manually or electrically operated low-voltage ac or dc power circuit breakers in individual grounded metal compartments, in three-pole, two-pole, or single-pole construction-is covered. Rated maximum voltage levels are 254 V, 508 V, or 635 V (ac) and 300/325 V, 800 V, 1000 V, 1200 V, 1600 V, or 3200 V (dc). The preferred continuous current ratings of the main bus in ac designs are 1600 A, 2000 A, 3000 A, 3200 A, 4000 A, or 5000 A. For dc designs, the preferred ratings are 1600 A, 2000 A, 2500 A, 3000 A, 4000 A, 5000 A, 6000 A, 8000 A, 10 000 A, or 12 000 A. The switchgear may also contain associated control, instruments, metering, protective, and regulating devices as necessary. The standard deals with service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.
Approved IEEE Draft Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear Amendment 1
IEEE Standard for Low-voltage Dc Power Circuit Breakers Used in Enclosures
Author:
Publisher:
ISBN: 9780738116648
Category : Electric circuit-breakers
Languages : en
Pages : 29
Book Description
This standard covers enclosed low-voltage dc power circuit breakers of the stationary or draw-out type of single- or two-pole construction with one or more rated mazimum voltages of 300 V, 325 V, 800 V, 1200 V, 1600 V, or 3200 V for applications on dc systems having nominal voltages of 250 V, 275 V, 750 V, 1000 V, 1500 V, or 3000 V, with general-purpose, high-speed, semi-high-speed and rectifier circuit breakers; manually or power-operated; and with or without electro-mechanical or electronic trip devices. It deals with service conditions, ratings, functional components, temperature limitations and classification of insulating materials, dielectric withstand voltage requirements, test procedures, and application.
Publisher:
ISBN: 9780738116648
Category : Electric circuit-breakers
Languages : en
Pages : 29
Book Description
This standard covers enclosed low-voltage dc power circuit breakers of the stationary or draw-out type of single- or two-pole construction with one or more rated mazimum voltages of 300 V, 325 V, 800 V, 1200 V, 1600 V, or 3200 V for applications on dc systems having nominal voltages of 250 V, 275 V, 750 V, 1000 V, 1500 V, or 3000 V, with general-purpose, high-speed, semi-high-speed and rectifier circuit breakers; manually or power-operated; and with or without electro-mechanical or electronic trip devices. It deals with service conditions, ratings, functional components, temperature limitations and classification of insulating materials, dielectric withstand voltage requirements, test procedures, and application.
IEEE Std C37.13.1-2016 (Revision of IEEE Std C37.13.1-2006
American Standard Safety Requirements for Low-voltage AC Power Circuit Breakers and Switchgear Assemblies
Author: American Standards Association
Publisher:
ISBN:
Category : Electric circuit-breakers
Languages : en
Pages : 20
Book Description
Publisher:
ISBN:
Category : Electric circuit-breakers
Languages : en
Pages : 20
Book Description
IEEE Standard Requirements for Electrical Control for AC High-voltage (>1000 V) Circuit Breakers
Author:
Publisher:
ISBN: 9780738195049
Category : Electric circuit-breakers
Languages : en
Pages : 17
Book Description
Abstract: Standard requirements for all types of electrical control circuits for ac high-voltage circuit breakers rated above 1000 V are given. This standard is applicable for any type of power-operated mechanism and for both ac and dc control power. Only basic control elements of the circuit breaker, including reclosing where required, are included in this standard. Devices or circuits for protective relaying, special interlocking, etc., are not included. Keywords: ac high-voltage circuit breakers, alarm circuits, auxiliary contacts, auxiliary switch, closing, control schemes, electrical control, grounding, heater circuits, IEEE C37.11, metal-clad switchgear, metal-enclosed switchgear, motor circuits, opening, re-closing, tripping.
Publisher:
ISBN: 9780738195049
Category : Electric circuit-breakers
Languages : en
Pages : 17
Book Description
Abstract: Standard requirements for all types of electrical control circuits for ac high-voltage circuit breakers rated above 1000 V are given. This standard is applicable for any type of power-operated mechanism and for both ac and dc control power. Only basic control elements of the circuit breaker, including reclosing where required, are included in this standard. Devices or circuits for protective relaying, special interlocking, etc., are not included. Keywords: ac high-voltage circuit breakers, alarm circuits, auxiliary contacts, auxiliary switch, closing, control schemes, electrical control, grounding, heater circuits, IEEE C37.11, metal-clad switchgear, metal-enclosed switchgear, motor circuits, opening, re-closing, tripping.
IEEE Standard Requirements for Electrical Control for Ac High-voltage Circuit Breakers Rated on a Symmetrical Current Basis
Author:
Publisher: Institute of Electrical & Electronics Engineers(IEEE)
ISBN: 9781559379175
Category : Electric circuit-breakers
Languages : en
Pages : 13
Book Description
Standard requirements for all types of electrical control circuits for ac high-voltage breakers rated above 1000 V are given. This standard is applicable for any type of power-operated mechanism and for both ac and dc control power. Only basic control elements of the circuit breaker, including reclosing where required, are included in this standard. Devices or circuits for protective relaying, special interlocking, etc., are not included.
Publisher: Institute of Electrical & Electronics Engineers(IEEE)
ISBN: 9781559379175
Category : Electric circuit-breakers
Languages : en
Pages : 13
Book Description
Standard requirements for all types of electrical control circuits for ac high-voltage breakers rated above 1000 V are given. This standard is applicable for any type of power-operated mechanism and for both ac and dc control power. Only basic control elements of the circuit breaker, including reclosing where required, are included in this standard. Devices or circuits for protective relaying, special interlocking, etc., are not included.