Accuracy of Three Screening-level Vapor Intrusion Models for Indoor Air PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Accuracy of Three Screening-level Vapor Intrusion Models for Indoor Air PDF full book. Access full book title Accuracy of Three Screening-level Vapor Intrusion Models for Indoor Air by . Download full books in PDF and EPUB format.

Accuracy of Three Screening-level Vapor Intrusion Models for Indoor Air

Accuracy of Three Screening-level Vapor Intrusion Models for Indoor Air PDF Author:
Publisher:
ISBN:
Category : Electronic books
Languages : en
Pages : 117

Book Description
Vapor intrusion models were developed to predict indoor air concentrations from subsurface sources and then calculate an associated risk using toxicological data and exposure scenarios for the building occupants. Prior to the issuance of final guidance documents in 2015, the United States Environmental Protection Agency (USEPA) guidance on vapor intrusion was in draft form since November 2002. This delay between the draft version and the final guidelines resulted in the utilization of varying methodologies for assessing vapor intrusion by the regulated community and as well as the regulators at both state and local levels. The purpose of this study was to evaluate the accuracy of screening-level vapor intrusion models, using soil vapor samples collected from three sites with known or suspected contamination, and to compare the predicted indoor air results with measured indoor air results. The models evaluated were the County of San Diego Department of Environmental Health Vapor Risk 2000 Model, the Department of Toxic Substances Control (DTSC) version of the Johnson and Ettinger Model (J&E Model), and the USEPA, Office of Solid Waste and Emergency Response (OSWER), Vapor Intrusion Screening Level Calculator (VISLC). The results of this study found that the Vapor Risk 2000 Model more accurately predicts indoor air concentrations, followed by the J&E Model and VISLC. While the Vapor Risk 2000 Model more closely predicts the indoor air concentration, it does have a tendency to underpredict. Due to the underpredictions, there is more potential for false negatives (i.e., screening out sites that do have a potential for vapor intrusion. Similar to previous studies, this study found the Vapor Risk 2000 and J&E Models both over and under predict the indoor air concentrations. This may not necessarily be a reflection on the model’s prediction ability, but rather the complexity of vapor intrusion and the confounders of indoor air. Combined with additional lines of evidence (e.g., indoor air sampling), these screening-level vapor intrusion models can assist decision makers in screening in or out sites that are susceptible to vapor intrusion.

Accuracy of Three Screening-level Vapor Intrusion Models for Indoor Air

Accuracy of Three Screening-level Vapor Intrusion Models for Indoor Air PDF Author:
Publisher:
ISBN:
Category : Electronic books
Languages : en
Pages : 117

Book Description
Vapor intrusion models were developed to predict indoor air concentrations from subsurface sources and then calculate an associated risk using toxicological data and exposure scenarios for the building occupants. Prior to the issuance of final guidance documents in 2015, the United States Environmental Protection Agency (USEPA) guidance on vapor intrusion was in draft form since November 2002. This delay between the draft version and the final guidelines resulted in the utilization of varying methodologies for assessing vapor intrusion by the regulated community and as well as the regulators at both state and local levels. The purpose of this study was to evaluate the accuracy of screening-level vapor intrusion models, using soil vapor samples collected from three sites with known or suspected contamination, and to compare the predicted indoor air results with measured indoor air results. The models evaluated were the County of San Diego Department of Environmental Health Vapor Risk 2000 Model, the Department of Toxic Substances Control (DTSC) version of the Johnson and Ettinger Model (J&E Model), and the USEPA, Office of Solid Waste and Emergency Response (OSWER), Vapor Intrusion Screening Level Calculator (VISLC). The results of this study found that the Vapor Risk 2000 Model more accurately predicts indoor air concentrations, followed by the J&E Model and VISLC. While the Vapor Risk 2000 Model more closely predicts the indoor air concentration, it does have a tendency to underpredict. Due to the underpredictions, there is more potential for false negatives (i.e., screening out sites that do have a potential for vapor intrusion. Similar to previous studies, this study found the Vapor Risk 2000 and J&E Models both over and under predict the indoor air concentrations. This may not necessarily be a reflection on the model’s prediction ability, but rather the complexity of vapor intrusion and the confounders of indoor air. Combined with additional lines of evidence (e.g., indoor air sampling), these screening-level vapor intrusion models can assist decision makers in screening in or out sites that are susceptible to vapor intrusion.

Vapor Intrusion Simulations and Risk Assessments

Vapor Intrusion Simulations and Risk Assessments PDF Author: Yijun Yao
Publisher: Springer Nature
ISBN: 9811927006
Category : Science
Languages : en
Pages : 133

Book Description
This book introduces key concepts in modeling and risk assessments of vapor intrusion, a process by which the subsurface volatile contaminants migrate into the building of concern. Soil vapor intrusion is the major exposure pathway for building occupants to chemicals from the subsurface, and its risk assessments determine the criteria of volatile contaminants in soil/groundwater in brownfield redevelopment. The chapters feature the recent advances in vapor intrusion studies and practices, including analytical and numerical modeling of vapor intrusion, statistical findings of United States Environmental Protection Agency’s Vapor Intrusion Database and Petroleum Vapor Intrusion Databases, the challenges of preferential pathways, and the application of building pressure cycling methods, and field practices of vapor intrusion risk assessments at developed contaminated sites and in brownfield redevelopment. This volume also summarizes the advantages and limits of current applications in vapor intrusion risk assessment, laying the groundwork for future research of better understanding in risk characterization of soil vapor intrusion using models. Written by experts in this field, Vapor Intrusion Simulations and Risk Assessments will serve as an invaluable reference for researchers, regulators, and practitioners, who are interested in perceiving the basic knowledge and current advances in risk assessments of soil vapor intrusion.

Vapor Intrusion Modeling

Vapor Intrusion Modeling PDF Author: Jessica Marie Friscia
Publisher:
ISBN:
Category :
Languages : en
Pages : 127

Book Description
Vapor intrusion is the migration of volatile organic compounds (VOCs) from a subsurface source into the indoor air of an overlying building. Vapor intrusion models, including the Johnson and Ettinger (J&E) model, can be used to predict the concentration of VOCs in the indoor air of a building based on a measured subsurface soil gas concentration or contaminant source concentrations, either in non-aqueous phase liquid (NAPL), groundwater, or soil. An analysis of two of the EPA-implemented J&E spreadsheet models, one that considers subsurface soil gas data and one that considers groundwater data, was conducted. The governing equations, assumptions, and limitations of these spreadsheet models were investigated. A value of information (Vol) worksheet was developed that can assist practitioners in deciding what additional data to collect as part of a remedial investigation. The Vol worksheet calculates how varying values of model input parameters affect the model-predicted indoor air carcinogenic risk. The worksheet then compares the user-defined target risk to the range of potential risk values for different combinations of varying parameters. The results of this analysis allow the user to determine which groups of parameters have the most impact on the model results. This information can assist the practitioner in deciding whether or not to collect additional data to reduce the uncertainty in the input parameters. The EPA J&E soil gas and groundwater spreadsheet models, as well as the Vol worksheet developed for each model, were applied to case study data for a trichloroethylene-impacted site in Rhode Island. The results of the J&E model and Vol worksheet analyses for this case study predicted incremental carcinogenic risk values for trichloroethylene (TCE) below the risk value calculated based on measured indoor air data. This comparison suggests the potential for other sources of TCE within the building. Groups of parameters were identified for each model that impacted the model-predicted carcinogenic risk. The development of a cost-benefit analysis, which would be used to quantify the value of obtaining additional data for these critical parameters, is recommended for future research.

Soil Screening Guidance

Soil Screening Guidance PDF Author:
Publisher:
ISBN:
Category : Soil pollution
Languages : en
Pages : 182

Book Description


WHO Guidelines for Indoor Air Quality

WHO Guidelines for Indoor Air Quality PDF Author:
Publisher: World Health Organization
ISBN:
Category : House & Home
Languages : en
Pages : 488

Book Description
This book presents WHO guidelines for the protection of public health from risks due to a number of chemicals commonly present in indoor air. The substances considered in this review, i.e. benzene, carbon monoxide, formaldehyde, naphthalene, nitrogen dioxide, polycyclic aromatic hydrocarbons (especially benzo[a]pyrene), radon, trichloroethylene and tetrachloroethylene, have indoor sources, are known in respect of their hazardousness to health and are often found indoors in concentrations of health concern. The guidelines are targeted at public health professionals involved in preventing health risks of environmental exposures, as well as specialists and authorities involved in the design and use of buildings, indoor materials and products. They provide a scientific basis for legally enforceable standards.

Health Effects Assessment Summary Tables

Health Effects Assessment Summary Tables PDF Author:
Publisher:
ISBN:
Category : Health risk assessment
Languages : en
Pages : 414

Book Description


Natural Attenuation of Fuels and Chlorinated Solvents in the Subsurface

Natural Attenuation of Fuels and Chlorinated Solvents in the Subsurface PDF Author: Todd H. Wiedemeier
Publisher: John Wiley & Sons
ISBN: 9780471197492
Category : Technology & Engineering
Languages : en
Pages : 634

Book Description
The first comprehensive guide to one of today's most innovative approaches to environmental contamination Natural attenuation is gaining increasing attention as a nonintrusive, cost-effective alternative to standard remediation techniques for environmental contamination. This landmark work presents the first in-depth examination of the theory, mechanisms, and application of natural attenuation. Written by four internationally recognized leaders in this approach, the book describes both biotic and abiotic natural attenuation processes, focusing on two of the environmental contaminants most frequently encountered in groundwater--fuels and chlorinated solvents. The authors draw on a wealth of combined experience to detail successful techniques for simulating natural attenuation processes and predicting their effectiveness in the field. They also show how natural attenuation works in the real world, using numerous examples and case studies from a wide range of leading-edge projects nationwide involving fuel hydrocarbons and chlorinated solvents. Finally, they discuss the evaluation and assessment of natural attenuation and explore the design of long-term monitoring programs. An indispensable reference for anyone working in environmental remediation, Natural Attenuation of Fuels and Chlorinated Solvents in the Subsurface is essential reading for scientists and engineers in a range of industries, as well as state and federal environmental regulators, and professors and graduate students in environmental or chemical engineering.

Evaluation of Vapor Intrusion Pathway Assessment Through Long-term Monitoring Studies

Evaluation of Vapor Intrusion Pathway Assessment Through Long-term Monitoring Studies PDF Author: Chase Weston Holton
Publisher:
ISBN:
Category : Chlorine compounds
Languages : en
Pages : 334

Book Description
Vapor intrusion (VI) pathway assessment often involves the collection and analysis of groundwater, soil gas, and indoor air data. There is temporal variability in these data, but little is understood about the characteristics of that variability and how it influences pathway assessment decision-making. This research included the first-ever collection of a long-term high-frequency indoor air data set at a house with VI impacts overlying a dilute chlorinated solvent groundwater plume. It also included periodic synoptic snapshots of groundwater and soil gas data and high-frequency monitoring of building conditions and environmental factors. Indoor air trichloroethylene (TCE) concentrations varied over three orders-of-magnitude under natural conditions, with the highest daily VI activity during fall, winter, and spring months. These data were used to simulate outcomes from common sampling strategies, with the result being that there was a high probability (up to 100%) of false-negative decisions and poor characterization of long-term exposure. Temporal and spatial variability in subsurface data were shown to increase as the sampling point moves from source depth to ground surface, with variability of an order-of-magnitude or more for sub-slab soil gas. It was observed that indoor vapor sources can cause subsurface vapor clouds and that it can take days to weeks for soil gas plumes created by indoor sources to dissipate following indoor source removal. A long-term controlled pressure method (CPM) test was conducted to assess its utility as an alternate approach for VI pathway assessment. Indoor air concentrations were similar to maximum concentrations under natural conditions (9.3 [micro]g/m3 average vs. 13 [micro]g/m3 for 24 h TCE data) with little temporal variability. A key outcome was that there were no occurrences of false-negative results. Results suggest that CPM tests can produce worst-case exposure conditions at any time of the year. The results of these studies highlight the limitations of current VI pathway assessment approaches and demonstrate the need for robust alternate diagnostic tools, such as CPM, that lead to greater confidence in data interpretation and decision-making.

Application of Risk-based Screening Levels and Decision Making to Sites with Impacted Soil and Groundwater: Background documentation for the development of Tier 1 soil and groundwater screening levels

Application of Risk-based Screening Levels and Decision Making to Sites with Impacted Soil and Groundwater: Background documentation for the development of Tier 1 soil and groundwater screening levels PDF Author:
Publisher:
ISBN:
Category : Environmental toxicology
Languages : en
Pages : 410

Book Description


Modelling of Pollutants in Complex Environmental Systems

Modelling of Pollutants in Complex Environmental Systems PDF Author: Grady Hanrahan
Publisher: ILM Publications
ISBN: 1906799016
Category : Nature
Languages : en
Pages : 489

Book Description
Environmental modelling has enjoyed a long tradition, but there is a defined need to continually address both the power and the limitations of such models, as well as their quantitative assessment. This book showcases modern environmental modelling methods, the basic theory behind them and their incorporation into complex environmental investigations. It highlights advanced computing technologies and how they have led to unprecedented and adaptive modelling, simulation and decision-support tools to study complex environmental systems, and how they can be applied to current environmental concerns. This volume is essential reading for researchers in academia, industry and government-related bodies who have a vested interest in all aspects of environmental modelling. Features include: A range of modern environmental modelling techniques are described by experts from around the world, including the USA, Canada, Australia, Europe and Thailand; many examples from air, water, soil/sediment and biological matrices are covered in detail throughout the book; key chapters are included on modelling uncertainty and sensitivity analysis; and, a selection of figures are provided in full colour to enable greater comprehension of the topics discussed.