USING THE FRAM ISOTOPIC ANALYSIS CODE IN THE REAL WORLD. PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download USING THE FRAM ISOTOPIC ANALYSIS CODE IN THE REAL WORLD. PDF full book. Access full book title USING THE FRAM ISOTOPIC ANALYSIS CODE IN THE REAL WORLD. by . Download full books in PDF and EPUB format.

USING THE FRAM ISOTOPIC ANALYSIS CODE IN THE REAL WORLD.

USING THE FRAM ISOTOPIC ANALYSIS CODE IN THE REAL WORLD. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description


USING THE FRAM ISOTOPIC ANALYSIS CODE IN THE REAL WORLD.

USING THE FRAM ISOTOPIC ANALYSIS CODE IN THE REAL WORLD. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description


Uranium Isotopic Analysis with the FRAM Isotopic Analysis Code

Uranium Isotopic Analysis with the FRAM Isotopic Analysis Code PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 28

Book Description
FRAM is the acronym for Fixed-energy Response-function Analysis with Multiple efficiency. This software was developed at Los Alamos National Laboratory originally for plutonium isotopic analysis. Later, it was adapted for uranium isotopic analysis in addition to plutonium. It is a code based on a self-calibration using several gamma-ray peaks for determining the isotopic ratios. The versatile-parameter database structure governs all facets of the data analysis. User editing of the parameter sets allows great flexibility in handling data with different isotopic distributions, interfering isotopes, and different acquisition parameters such as energy calibration and detector type.

Improvement in the Plutonium Parameter Files of the FRAM Isotopic Analysis Code

Improvement in the Plutonium Parameter Files of the FRAM Isotopic Analysis Code PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
The isotopic analysis code Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) employs user-editable parameter sets to analyze a broad range of sample types. This report presents new parameter files, based upon a new set of plutonium branding ratios, which give more accurate isotope results than the current parameter files that use FRAM.

FRAM's Isotopic Uncertainty Analysis

FRAM's Isotopic Uncertainty Analysis PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 9

Book Description
The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory to measure the gamma-ray spectrometry of the isotopic composition of plutonium, uranium, and other actinides. They have studied and identified two different kinds of errors from FRAM analysis: random and systematic. The random errors come mainly from statistics and are easily determined. The systematic errors can come from a variety of sources and can be very difficult to determine. The authors carefully examined the FRAM analytical results of the archival plutonium data and of the data specifically acquired for this isotopic uncertainty analysis project, and found the relationship between the systematic errors and other parameters. They determined that the FRAM's systematic errors could be expressed as functions of the peak resolution and shape, region of analysis, and burnup (for plutonium) or enrichment (for uranium). All other parameters such as weight, matrix material, shape, size, container, electronics, detector, input rate, etc., contribute little to the systematic error or they contribute to the peak resolution and shape and then their contributions can be determined from the peak resolution and shape.

Achievements in Testing of the MGA and FRAM Isotopic Software Codes Under the DOE

Achievements in Testing of the MGA and FRAM Isotopic Software Codes Under the DOE PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
DOE/NNSA and IRSN collaborated on a study of gamma-ray instruments and analysis methods used to perform isotopic measurements of special nuclear materials. The two agencies agreed to collaborate on the project in response to inconsistencies that were found in the various versions of software and hardware used to determine the isotopic abundances of uranium and plutonium. IRSN used software developed internally to test the MGA and FRAM isotopic analysis codes for criteria used to stop data acquisition. The stop-criterion test revealed several unusual behaviors in both the MGA and FRAM software codes.

Isotopic Analysis

Isotopic Analysis PDF Author: Frank Vanhaecke
Publisher: John Wiley & Sons
ISBN: 3527650504
Category : Science
Languages : en
Pages : 565

Book Description
Edited by two very well-known and respected scientists in the field, this excellent practical guide is the first to cover the fundamentals and a wide range of applications, as well as showing readers how to efficiently use this increasingly important technique. From the contents: * The Isotopic Composition of the Elements * Single-Collector ICP-MS * Multi-Collector ICP-MS * Advances in Laser Ablation - Multi-Collector ICP-MS * Correction for Instrumental Mass Discrimination in Isotope Ratio Determination with Multi-Collector ICP-MS * Reference Materials in Isotopic Analysis * Quality Control in Isotope Ratio Applications * Determination of Trace Elements and Elemental Species Using Isotope Dilution ICP-MS * Geochronological Dating * Application of Multi-Collector ICP-MS to Isotopic Analysis in Cosmochemistry * Establishing the Basis for Using Stable Isotope Ratios of Metals as Paleoredox Proxies * Isotopes as Tracers of Elements Across the Geosphere-Biosphere Interface * Archaeometric Applications * Forensics Applications * Nuclear Applications * The Use of Stable Isotope Techniques for Studying Mineral and Trace Element Metabolism in Humans * Isotopic Analysis via Multi-Collector ICP-MS in Elemental Speciation A must-have for newcomers as well as established scientists seeking an overview of isotopic analysis via ICP-MS.

Evaluation and Modification of Isotopic Analysis Code for Microcalorimeter Data

Evaluation and Modification of Isotopic Analysis Code for Microcalorimeter Data PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description


Comparison of Three Gamma Ray Isotopic Determination Codes: FRAM, MGA, and TRIFID.

Comparison of Three Gamma Ray Isotopic Determination Codes: FRAM, MGA, and TRIFID. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Book Description


Experience with a General Gamma-Ray Isotopic Analysis Approach

Experience with a General Gamma-Ray Isotopic Analysis Approach PDF Author: W. D. Ruhter
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
The gamma-ray data analysis methodology originally developed for the MGA code to determine the relative detection efficiency curve may also be used to determine the relative amounts of the isotopes being measured. This analysis approach is based on the fact that the intensity of any given gamma ray from a sample is determined by the amount of the emitting isotope present in the sample, the emission probability for the gamma ray being measured, the sample self attenuation, the attenuation due to absorbers between the sample and detector, and the detector efficiency. An equation can be written that describes a measured gamma-ray peak intensity in terms of these parameters. By selecting appropriate gamma-ray peaks from the isotopes of interest, we can solve a set of equations for the values of the parameters in any particular measurement including the relative amounts of the selected isotopes. The equations representing the peak intensities are very nonlinear and require an iterative least squares method to solve. We have developed software to ensure that during the iterative process the parameters stay within their appropriate ranges and converge properly in solving the set of equations under various measurement conditions. We have utilized and reported on this approach for determining the plutonium isotopic abundances in samples enriched in Pu-238 and to determine the U-235 enrichment of uranium samples in thick-walled containers. Recently, we have used this approach to determine the plutonium isotopic abundances of plutonium samples in thick-walled containers. We will report on this most recent application, and how this general approach can be adapted quickly to any isotopic analysis problem.

Handbook of Nuclear Chemistry

Handbook of Nuclear Chemistry PDF Author: Attila VĂ©rtes
Publisher: Springer Science & Business Media
ISBN: 144190719X
Category : Science
Languages : en
Pages : 3693

Book Description
This revised and extended 6 volume handbook set is the most comprehensive and voluminous reference work of its kind in the field of nuclear chemistry. The Handbook set covers all of the chemical aspects of nuclear science starting from the physical basics and including such diverse areas as the chemistry of transactinides and exotic atoms as well as radioactive waste management and radiopharmaceutical chemistry relevant to nuclear medicine. The nuclear methods of the investigation of chemical structure also receive ample space and attention. The international team of authors consists of scores of world-renowned experts - nuclear chemists, radiopharmaceutical chemists and physicists - from Europe, USA, and Asia. The Handbook set is an invaluable reference for nuclear scientists, biologists, chemists, physicists, physicians practicing nuclear medicine, graduate students and teachers - virtually all who are involved in the chemical and radiopharmaceutical aspects of nuclear science. The Handbook set also provides further reading via the rich selection of references.