Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Unapproved IEEE Draft Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear---Amendment 2
IEEE Std PC37.20.1b/D2
IEEE Std PC37.20.1b/D3
Approved IEEE Draft Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear Amendment 1
C37.20.1b-2006 IEEE Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear Amendment 2: Additional Requirements for Control and Auxiliary Power Wiring in DC Traction Power Switchgear
Author:
Publisher:
ISBN:
Category : Electric circuit-breakers
Languages : en
Pages :
Book Description
Publisher:
ISBN:
Category : Electric circuit-breakers
Languages : en
Pages :
Book Description
IEEE Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear Amendment 1
IEEE Standard for Metal-enclosed Low-voltage Power Circuit Breaker Switchgear
Author:
Publisher:
ISBN: 9780738133034
Category : Electric circuit-breakers
Languages : en
Pages : 55
Book Description
Abstract: Low-voltage metal-enclosed switchgear-which contains either stationary or drawout, manually or electrically operated low-voltage ac or dc power circuit breakers in individual grounded metal compartments, in three-pole, two-pole, or single-pole construction-is covered. Rated maximum voltage levels are 254 V, 508 V, or 635 V (ac) and 300/325 V, 800 V, 1000 V, 1200 V, 1600 V, or 3200 V (dc). The preferred continuous current ratings of the main bus in ac designs are 1600 A, 2000 A, 3000 A, 3200 A, 4000 A, or 5000 A. For dc designs, the preferred ratings are 1600 A, 2000 A, 2500 A, 3000 A, 4000 A, 5000 A, 6000 A, 8000 A, 10 000 A, or 12 000 A. The switchgear may also contain associated control, instruments, metering, protective, and regulating devices as necessary. The standard deals with service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.
Publisher:
ISBN: 9780738133034
Category : Electric circuit-breakers
Languages : en
Pages : 55
Book Description
Abstract: Low-voltage metal-enclosed switchgear-which contains either stationary or drawout, manually or electrically operated low-voltage ac or dc power circuit breakers in individual grounded metal compartments, in three-pole, two-pole, or single-pole construction-is covered. Rated maximum voltage levels are 254 V, 508 V, or 635 V (ac) and 300/325 V, 800 V, 1000 V, 1200 V, 1600 V, or 3200 V (dc). The preferred continuous current ratings of the main bus in ac designs are 1600 A, 2000 A, 3000 A, 3200 A, 4000 A, or 5000 A. For dc designs, the preferred ratings are 1600 A, 2000 A, 2500 A, 3000 A, 4000 A, 5000 A, 6000 A, 8000 A, 10 000 A, or 12 000 A. The switchgear may also contain associated control, instruments, metering, protective, and regulating devices as necessary. The standard deals with service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.