Motion Correction in Thoracic Positron Emission Tomography PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Motion Correction in Thoracic Positron Emission Tomography PDF full book. Access full book title Motion Correction in Thoracic Positron Emission Tomography by Fabian Gigengack. Download full books in PDF and EPUB format.

Motion Correction in Thoracic Positron Emission Tomography

Motion Correction in Thoracic Positron Emission Tomography PDF Author: Fabian Gigengack
Publisher: Springer
ISBN: 3319083929
Category : Computers
Languages : en
Pages : 98

Book Description
Respiratory and cardiac motion leads to image degradation in Positron Emission Tomography (PET), which impairs quantification. In this book, the authors present approaches to motion estimation and motion correction in thoracic PET. The approaches for motion estimation are based on dual gating and mass-preserving image registration (VAMPIRE) and mass-preserving optical flow (MPOF). With mass-preservation, image intensity modulations caused by highly non-rigid cardiac motion are accounted for. Within the image registration framework different data terms, different variants of regularization and parametric and non-parametric motion models are examined. Within the optical flow framework, different data terms and further non-quadratic penalization are also discussed. The approaches for motion correction particularly focus on pipelines in dual gated PET. A quantitative evaluation of the proposed approaches is performed on software phantom data with accompanied ground-truth motion information. Further, clinical applicability is shown on patient data. The book concludes with an outlook of recent developments and potential future advances in the field of PET motion correction.

Motion Correction in Thoracic Positron Emission Tomography

Motion Correction in Thoracic Positron Emission Tomography PDF Author: Fabian Gigengack
Publisher: Springer
ISBN: 3319083929
Category : Computers
Languages : en
Pages : 98

Book Description
Respiratory and cardiac motion leads to image degradation in Positron Emission Tomography (PET), which impairs quantification. In this book, the authors present approaches to motion estimation and motion correction in thoracic PET. The approaches for motion estimation are based on dual gating and mass-preserving image registration (VAMPIRE) and mass-preserving optical flow (MPOF). With mass-preservation, image intensity modulations caused by highly non-rigid cardiac motion are accounted for. Within the image registration framework different data terms, different variants of regularization and parametric and non-parametric motion models are examined. Within the optical flow framework, different data terms and further non-quadratic penalization are also discussed. The approaches for motion correction particularly focus on pipelines in dual gated PET. A quantitative evaluation of the proposed approaches is performed on software phantom data with accompanied ground-truth motion information. Further, clinical applicability is shown on patient data. The book concludes with an outlook of recent developments and potential future advances in the field of PET motion correction.

Respiratory Motion Correction on 3D Positron Emission Tomography Images

Respiratory Motion Correction on 3D Positron Emission Tomography Images PDF Author: Mohammad Dawood
Publisher:
ISBN:
Category :
Languages : en
Pages : 142

Book Description


Ultra-low-dose CT-based Attenuation Correction for Respiratory Motion Compensation in PET/CT Imaging

Ultra-low-dose CT-based Attenuation Correction for Respiratory Motion Compensation in PET/CT Imaging PDF Author: Tzu-Cheng Lee
Publisher:
ISBN:
Category :
Languages : en
Pages : 153

Book Description
Positron emission tomography (PET) is a commonly used imaging tool in the management of patients with lung cancer and is of considerable interest in quantitative imaging of the thorax. Mismatch of PET data with computed tomography (CT) attenuation correction (CTAC) due to respiratory motion is a known source of errors in PET imaging. In theory, this can be corrected by matching individual PET and CT phases which have been generated by respiratory-correlated PET and CT. However, due to the high variability of patient breathing patterns and the nature of the scanning time differences between PET and CT, current respiratory-gated CTAC protocols for the irregular breather may cause additional bias in the PET image values. A ten-fold extension of the CT scanning time duration helps reduce PET imaging bias, but leads to the higher radiation dose to the patient. Lowering the CT source flux level to reduce dose, however, leads to increased noise and bias. Here we test the possibility of using model based iterative reconstruction algorithms (MBIRs) for generating the sparse-view, ultra-low-dose (i.e. an order lower than current low-dose protocols) CTAC images for both phantom and patient PET data. We also propose a new variance estimation model, which considers statistical changes caused by the non-positivity correction process, for the MBIR algorithms. The model based iterative CT reconstruction approach does generate more accurate CTAC map compared to current approaches. However, since iterative reconstruction algorithms typically assume a normal distribution of the attenuation data, we tested if the assumption is still valid in the ultra-low-dose regime. The simulation and empirical ultra-low-dose CT studies showed a skewed post-log likelihood distribution in certain ranges. The information delineates the estimation limits of model based iterative reconstruction approach on the ultra-low-dose CT imaging, and potentially helps guide scanning protocols customized for a lowest-reasonable radiation dose.

Correction Techniques in Emission Tomography

Correction Techniques in Emission Tomography PDF Author: Mohammad Dawood
Publisher: CRC Press
ISBN: 1439812985
Category : Medical
Languages : en
Pages : 304

Book Description
Written by an interdisciplinary team of medical doctors, computer scientists, physicists, engineers, and mathematicians, Correction Techniques in Emission Tomography presents various correction methods used in emission tomography to generate and enhance images. It discusses the techniques from a computer science, mathematics, and physics viewpoint. The book gives a comprehensive overview of correction techniques at different levels of the data processing workflow. It covers nuclear medicine imaging, hybrid emission tomography (PET-CT, SPECT-CT, PET-MRI, PET-ultrasound), and optical imaging (fluorescence molecular tomography). It illustrates basic principles as well as recent advances, such as model-based iterative algorithms and 4D methods. An important aspect of the book is on new and sophisticated motion correction techniques in PET imaging. These techniques enable high-resolution, high-quality images, leading to better imaging analysis and image-based diagnostics. Reflecting state-of-the-art research, this volume explores the range of problems that occur in emission tomography. It looks at how the resulting images are affected and presents practical compensation methods to overcome the problems and improve the images.

Respiratory Motion Modeling for Use in Diagnostic Imaging and Radiation Therapy

Respiratory Motion Modeling for Use in Diagnostic Imaging and Radiation Therapy PDF Author: Hadi Fayad
Publisher:
ISBN:
Category :
Languages : en
Pages : 198

Book Description
One of the most important parameters reducing the sensitivity and specificity in the thoracic and abdominal areas is respiratory motion and associated deformations which represent today an important challenge in medical imaging. In addition, respiratory motion reduces accuracy in image fusion from combined positron emission tomography computed tomography (PET/CT) systems. Solutions presented to date include respiratory synchronized PET and CT acquisitions. However, differences between acquired 4D PET and corresponding CT image series have been reported due to differences in respiration conditions during PET and CT acquisitions. In addition, the radiation dose burden resulting from a 4D CT acquisition may not be justifiable for every patient. The first objective of this thesis was to generate dynamic CT images from one reference CT image; based on deformation matrices obtained from the elastic registration of 4D non attenuation corrected PET images. Such an approach eliminates, on one hand the need for the acquisition of dynamic CT, while at the same time ensuring the good matching between CT and PET images. The second objective was to develop and evaluate methods of building patient specific respiratory motion models and at as a second step more developed generic respiratory motion models. These models relate the internal motion to the parameters of an external surrogate signal (PET respiratory signal or patient's surface) that can be acquired during data acquisition and treatment delivery. Finally, the two developed models were validated and used in the PET respiratory motion and attenuation correction and in radiation therapy applications.

Lesion Quantification in Respiratory Motion Compensated Positron Emission Tomography

Lesion Quantification in Respiratory Motion Compensated Positron Emission Tomography PDF Author: Nicole Christine Detorie
Publisher:
ISBN:
Category :
Languages : en
Pages : 810

Book Description


Respiratory Motion Correction for Positron Emission Tomography

Respiratory Motion Correction for Positron Emission Tomography PDF Author: Nikolaos Dikaios
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description


Respiratory Motion Correction in Positron Emission Tomography

Respiratory Motion Correction in Positron Emission Tomography PDF Author: Wenjia Bai
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description


Respiratory and Cardiac Gating in PET, An Issue of PET Clinics

Respiratory and Cardiac Gating in PET, An Issue of PET Clinics PDF Author: Habib Zaidi
Publisher: Elsevier Health Sciences
ISBN: 1455772208
Category : Medical
Languages : en
Pages : 260

Book Description
The complexity of issues associated with gating studies with PET imaging are mostly unknown among practitioners of the field, which is posing a significant danger to those who undergo such studies. This is particularly true for respiratory gating examination. Topics in this issue include both basic and clinical topics, including views from radiation oncology physicians.

Numerical Methods for Image Registration

Numerical Methods for Image Registration PDF Author: Jan Modersitzki
Publisher: Oxford University Press, USA
ISBN: 0198528418
Category : Computers
Languages : en
Pages : 210

Book Description
This text provides an introduction to image registration with particular emphasis on numerical methods in medical imaging. Designed for researchers in industry and academia, it should also be a suitable study guide for graduate mathematicians, computer scientists and medical physicists.