Author: A. D. Stockton
Publisher:
ISBN:
Category : Geology
Languages : en
Pages : 92
Book Description
A Reservoir Assessment of The Geysers Geothermal Field
Author: A. D. Stockton
Publisher:
ISBN:
Category : Geology
Languages : en
Pages : 92
Book Description
Publisher:
ISBN:
Category : Geology
Languages : en
Pages : 92
Book Description
Reservoir Assessment of The Geysers Geothermal Field
Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Big Sulphur Creek fault zone, in The Geysers Geothermal field, may be part of a deep-seated, wrench-style fault system. Hydrothermal fluid in the field reservoir may rise through conduits beneath the five main anomalies associated with the Big Sulphur Creek wrench trend. Some geophysical anomalies (electrical resistivity and audio-magnetotelluric) evidently are caused by the hot water geothermal field or zones of altered rocks; others (gravity, P-wave delays, and possibly electrical resistivity) probably respresent the underlying heat source, a possible magma chamber; and others (microearthquake activity) may be related to the steam reservoir. A large negative gravity anomaly and a few low-resistivity anomalies suggest areas generally favorable for the presence of steam zones, but these anomalies apparently do not directly indicate the known steam reservoir. At the current generating capacity of 930 MWe, the estimated life of The Geysers Geothermal field reservoir is 129 years. The estimated reservoir life is 60 years for the anticipated maximum generating capacity of 2000 MWe as of 1990. Wells at The Geysers are drilled with conventional drilling fluid (mud) until the top of the steam reservoir is reached; then, they are drilled with air. Usually, mud, temperature, caliper, dual induction, and cement bond logs are run on the wells.
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Big Sulphur Creek fault zone, in The Geysers Geothermal field, may be part of a deep-seated, wrench-style fault system. Hydrothermal fluid in the field reservoir may rise through conduits beneath the five main anomalies associated with the Big Sulphur Creek wrench trend. Some geophysical anomalies (electrical resistivity and audio-magnetotelluric) evidently are caused by the hot water geothermal field or zones of altered rocks; others (gravity, P-wave delays, and possibly electrical resistivity) probably respresent the underlying heat source, a possible magma chamber; and others (microearthquake activity) may be related to the steam reservoir. A large negative gravity anomaly and a few low-resistivity anomalies suggest areas generally favorable for the presence of steam zones, but these anomalies apparently do not directly indicate the known steam reservoir. At the current generating capacity of 930 MWe, the estimated life of The Geysers Geothermal field reservoir is 129 years. The estimated reservoir life is 60 years for the anticipated maximum generating capacity of 2000 MWe as of 1990. Wells at The Geysers are drilled with conventional drilling fluid (mud) until the top of the steam reservoir is reached; then, they are drilled with air. Usually, mud, temperature, caliper, dual induction, and cement bond logs are run on the wells.
A Reservoir Assessment of the Geysers Geothermal Field
Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Big Sulphur Creek fault zone, in The Geysers Geothermal field, may be part of a deep-seated, wrench-style fault system. Hydrothermal fluid reservoir may rise through conduits beneath the five main anomalies associated with the Big Sulphur Creek wrench trend. Upon moderately dipping, fracture network. Condensed steam at the steep reservoir flank drains back to the hot water table. These flanks are defined roughly by marginally-producing geothermal wells. Field extensions are expected to be on the southeast and northwest. Some geophysical anomalies (electrical resistivity and audio-magnetotelluric) evidently are caused by the hot water geothermal field or zones of altered rocks; others (gravity, P-wave delays, and possibly electrical resistivity) probably represent the underlying heat source, a possible magma chamber; and others (microearthquake activity) may be related to the steam reservoir. A large negative gravity anomaly and a few low-resitivity anomalies suggest areas generally favorable for the presence of steam zones, but these anomalies apparently do not directly indicate the known steam reservoir. Monitoring gravity and geodetic changes with time and mapping microearthquake activity are methods that show promise for determining reservoir size, possible recharge, production lifetime, and other characteristics of the known stream field. Seismic reflection data may contribute to the efficient exploitation of the field by identifying fracture zones that serve as conduits for the steam. (DJE-2005).
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Big Sulphur Creek fault zone, in The Geysers Geothermal field, may be part of a deep-seated, wrench-style fault system. Hydrothermal fluid reservoir may rise through conduits beneath the five main anomalies associated with the Big Sulphur Creek wrench trend. Upon moderately dipping, fracture network. Condensed steam at the steep reservoir flank drains back to the hot water table. These flanks are defined roughly by marginally-producing geothermal wells. Field extensions are expected to be on the southeast and northwest. Some geophysical anomalies (electrical resistivity and audio-magnetotelluric) evidently are caused by the hot water geothermal field or zones of altered rocks; others (gravity, P-wave delays, and possibly electrical resistivity) probably represent the underlying heat source, a possible magma chamber; and others (microearthquake activity) may be related to the steam reservoir. A large negative gravity anomaly and a few low-resitivity anomalies suggest areas generally favorable for the presence of steam zones, but these anomalies apparently do not directly indicate the known steam reservoir. Monitoring gravity and geodetic changes with time and mapping microearthquake activity are methods that show promise for determining reservoir size, possible recharge, production lifetime, and other characteristics of the known stream field. Seismic reflection data may contribute to the efficient exploitation of the field by identifying fracture zones that serve as conduits for the steam. (DJE-2005).
Reservoir Engineering Assessment of Geothermal Systems
Author:
Publisher:
ISBN:
Category : Geothermal engineering
Languages : en
Pages : 258
Book Description
Publisher:
ISBN:
Category : Geothermal engineering
Languages : en
Pages : 258
Book Description
A Reservoir Assessment of the Geysers Geothermal Field
Author:
Publisher:
ISBN:
Category : Geothermal resources
Languages : en
Pages : 104
Book Description
Publisher:
ISBN:
Category : Geothermal resources
Languages : en
Pages : 104
Book Description
Monograph on the Geysers Geothermal Field
Author: Claudia Stone
Publisher:
ISBN:
Category : Technology & Engineering
Languages : en
Pages : 348
Book Description
Publisher:
ISBN:
Category : Technology & Engineering
Languages : en
Pages : 348
Book Description
Geothermal Reservoir Engineering
Author: Malcomm Grant
Publisher: Elsevier
ISBN: 0323152910
Category : Technology & Engineering
Languages : en
Pages : 384
Book Description
Geothermal Reservoir Engineering offers a comprehensive account of geothermal reservoir engineering and a guide to the state-of-the-art technology, with emphasis on practicality. Topics covered include well completion and warm-up, flow testing, and field monitoring and management. A case study of a geothermal well in New Zealand is also presented. Comprised of 10 chapters, this book opens with an overview of geothermal reservoirs and the development of geothermal reservoir engineering as a discipline. The following chapters focus on conceptual models of geothermal fields; simple models that illustrate some of the processes taking place in geothermal reservoirs under exploitation; measurements in a well from spudding-in up to first discharge; and flow measurement. The next chapter provides a case history of one well in the Broadlands Geothermal Field in New Zealand, with particular reference to its drilling, measurement, discharge, and data analysis/interpretation. The changes that have occurred in exploited geothermal fields are also reviewed. The final chapter considers three major problems of geothermal reservoir engineering: rapid entry of external cooler water, or return of reinjected water, in fractured reservoirs; the effects of exploitation on natural discharges; and subsidence. This monograph serves as both a text for students and a manual for working professionals in the field of geothermal reservoir engineering. It will also be of interest to engineers and scientists of other disciplines.
Publisher: Elsevier
ISBN: 0323152910
Category : Technology & Engineering
Languages : en
Pages : 384
Book Description
Geothermal Reservoir Engineering offers a comprehensive account of geothermal reservoir engineering and a guide to the state-of-the-art technology, with emphasis on practicality. Topics covered include well completion and warm-up, flow testing, and field monitoring and management. A case study of a geothermal well in New Zealand is also presented. Comprised of 10 chapters, this book opens with an overview of geothermal reservoirs and the development of geothermal reservoir engineering as a discipline. The following chapters focus on conceptual models of geothermal fields; simple models that illustrate some of the processes taking place in geothermal reservoirs under exploitation; measurements in a well from spudding-in up to first discharge; and flow measurement. The next chapter provides a case history of one well in the Broadlands Geothermal Field in New Zealand, with particular reference to its drilling, measurement, discharge, and data analysis/interpretation. The changes that have occurred in exploited geothermal fields are also reviewed. The final chapter considers three major problems of geothermal reservoir engineering: rapid entry of external cooler water, or return of reinjected water, in fractured reservoirs; the effects of exploitation on natural discharges; and subsidence. This monograph serves as both a text for students and a manual for working professionals in the field of geothermal reservoir engineering. It will also be of interest to engineers and scientists of other disciplines.
Geothermal Energy Update
Author:
Publisher:
ISBN:
Category : Geothermal engineering
Languages : en
Pages : 444
Book Description
Publisher:
ISBN:
Category : Geothermal engineering
Languages : en
Pages : 444
Book Description
Permeability, Electrical Impedance, and Acoustic Velocities on Reservoir Rocks from the Geysers Geothermal Field
Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Previous measurements of acoustic velocities on NEGU- 17 cores indicate that saturation effects are significant enough to cause Vp/Vs anomalies observed in the field. In this study we report on the results of new measurements on core recently recovered from SB-15-D along with some additional measurements on the NEGU-17 cores. The measurements indicate correlations between mechanical, transport, and water storage properties of the matrix which may prove useful for reservoir assessment and management. The SB-15-D material is found to be similar to the NEGU-17 material in terms of acoustic velocities, being characterized by a notably weak pressure dependence on the velocities and a modest Vp/Vs signature of saturation. The effect of saturation on Vp/Vs appears to result in part from a chemo-mechanical weakening of the shear modulus due to the presence of water. Electrical properties of SB-15-D material are qualitatively similar to those of the NEGU-17 cores, although resistivities of SB-15-D cores are notably lower and dielectric permittivities higher than in their NEGU- 17 counterparts. While some limited correlations of measured properties with depth are noted, no clear change in character is observed within SB-15-D cores which can be associated with the proposed cap-rock/reservoir boundary.
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Previous measurements of acoustic velocities on NEGU- 17 cores indicate that saturation effects are significant enough to cause Vp/Vs anomalies observed in the field. In this study we report on the results of new measurements on core recently recovered from SB-15-D along with some additional measurements on the NEGU-17 cores. The measurements indicate correlations between mechanical, transport, and water storage properties of the matrix which may prove useful for reservoir assessment and management. The SB-15-D material is found to be similar to the NEGU-17 material in terms of acoustic velocities, being characterized by a notably weak pressure dependence on the velocities and a modest Vp/Vs signature of saturation. The effect of saturation on Vp/Vs appears to result in part from a chemo-mechanical weakening of the shear modulus due to the presence of water. Electrical properties of SB-15-D material are qualitatively similar to those of the NEGU-17 cores, although resistivities of SB-15-D cores are notably lower and dielectric permittivities higher than in their NEGU- 17 counterparts. While some limited correlations of measured properties with depth are noted, no clear change in character is observed within SB-15-D cores which can be associated with the proposed cap-rock/reservoir boundary.
The Geysers--three Decades of Achievement
Author: Geothermal Resources Council. Annual Meeting
Publisher:
ISBN:
Category : Technology & Engineering
Languages : en
Pages : 708
Book Description
Publisher:
ISBN:
Category : Technology & Engineering
Languages : en
Pages : 708
Book Description