Rapid Mass Spectrometry Method for Uranium and Plutonium PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Rapid Mass Spectrometry Method for Uranium and Plutonium PDF full book. Access full book title Rapid Mass Spectrometry Method for Uranium and Plutonium by . Download full books in PDF and EPUB format.

Rapid Mass Spectrometry Method for Uranium and Plutonium

Rapid Mass Spectrometry Method for Uranium and Plutonium PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Book Description
A new, rapid sample preparation method to improve the assay of uranium and plutonium by mass spectrometry has been developed at the Westinghouse Savannah River Site (SRS). The method is applied to the analysis of mixed plutonium-uranium oxide materials but can be applied to low-level mass spectrometry analyses as well. The new method uses a single extraction chromatographic column to separate and purify both uranium and plutonium for isotopic assay by thermal ionization mass spectrometry. A dual uranium/plutonium spike isotope dilution technique is used to allow rapid analysis of uranium/plutonium content and isotopics. A single UTEVA Resin column is utilized to simultaneously separate both uranium and plutonium from the sample matrix. The plutonium and uranium can rapidly removed from the column separately or eluted together for analysis. This new method combines sample preparation into a single, effective separation step that significantly reduces sample preparation time and costs.

Rapid Mass Spectrometry Method for Uranium and Plutonium

Rapid Mass Spectrometry Method for Uranium and Plutonium PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Book Description
A new, rapid sample preparation method to improve the assay of uranium and plutonium by mass spectrometry has been developed at the Westinghouse Savannah River Site (SRS). The method is applied to the analysis of mixed plutonium-uranium oxide materials but can be applied to low-level mass spectrometry analyses as well. The new method uses a single extraction chromatographic column to separate and purify both uranium and plutonium for isotopic assay by thermal ionization mass spectrometry. A dual uranium/plutonium spike isotope dilution technique is used to allow rapid analysis of uranium/plutonium content and isotopics. A single UTEVA Resin column is utilized to simultaneously separate both uranium and plutonium from the sample matrix. The plutonium and uranium can rapidly removed from the column separately or eluted together for analysis. This new method combines sample preparation into a single, effective separation step that significantly reduces sample preparation time and costs.

Chemical Aspects of the Precise and Accurate Determination of Uranium and Plutonium from Nuclear Fuel Solutions

Chemical Aspects of the Precise and Accurate Determination of Uranium and Plutonium from Nuclear Fuel Solutions PDF Author: Olli J. Heinonen
Publisher:
ISBN:
Category : Nuclear fuel elements
Languages : en
Pages : 80

Book Description


Standard Test Method for Uranium and Plutonium Concentrations and Isotopic Abundances by Thermal Ionization Mass Spectrometry

Standard Test Method for Uranium and Plutonium Concentrations and Isotopic Abundances by Thermal Ionization Mass Spectrometry PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Book Description


Rapid Determination of Uranium in Natural Waters by Thermal Emission Mass Spectrometry

Rapid Determination of Uranium in Natural Waters by Thermal Emission Mass Spectrometry PDF Author: James Robert Ferguson
Publisher:
ISBN:
Category : Mass spectrometry
Languages : en
Pages : 18

Book Description


Investigation of Alternate Analytical Techniques to Isotope Dilution Mass Spectrometry for Measurement of Uranium and Plutonium in Input Accountability Tanks

Investigation of Alternate Analytical Techniques to Isotope Dilution Mass Spectrometry for Measurement of Uranium and Plutonium in Input Accountability Tanks PDF Author: Robert D. Hamman
Publisher:
ISBN:
Category : Chemistry, Analytic
Languages : en
Pages : 28

Book Description


High Precision Isotopic Analyses of Uranium and Plutonium by Total Sample Volatilization and Signal Integration

High Precision Isotopic Analyses of Uranium and Plutonium by Total Sample Volatilization and Signal Integration PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Techniques have been developed which permit rapid, high-precision analyses of uranium and plutonium by multiple-filament thermal ionization mass spectrometry utilizing a commercial multicollector instrument. The salient feature of the method is volatilization of the entire sample while simultaneously integrating the signal from each isotope, thus virtually eliminating the effects of isotope fractionation in the evaporation process. The method permits the analysis of samples much smaller than required for conventional techniques using Faraday collectors and is expected to have application in the analysis of many elements in addition to uranium and plutonium. Run-to-run reproducibilities of

Isotopic Analysis of Plutonium and Uranium by Mass Spectrometer

Isotopic Analysis of Plutonium and Uranium by Mass Spectrometer PDF Author: A. H. TURNBULL
Publisher:
ISBN:
Category :
Languages : en
Pages : 4

Book Description


Standard test method for determination of uranium or plutonium isotopic composition or concentration by the total evaporation method using a thermal ionization mass spectrometer

Standard test method for determination of uranium or plutonium isotopic composition or concentration by the total evaporation method using a thermal ionization mass spectrometer PDF Author: ASTM International
Publisher:
ISBN:
Category : Chemistry, Analytic
Languages : en
Pages : 20

Book Description


Standard Test Method for Determination of Uranium or Plutonium Isotopic Composition or Concentration by the Total Evaporation Method Using a Thermal Ionization Mass Spectrometer

Standard Test Method for Determination of Uranium or Plutonium Isotopic Composition or Concentration by the Total Evaporation Method Using a Thermal Ionization Mass Spectrometer PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Book Description


Development of Dynamic Multicollection for Uranium and Plutonium Analysis in Thermal Ionisation Mass Spectrometry

Development of Dynamic Multicollection for Uranium and Plutonium Analysis in Thermal Ionisation Mass Spectrometry PDF Author: J-C. Dubois
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description