Author:
Publisher:
ISBN:
Category : Environmental impact analysis
Languages : en
Pages : 126
Book Description
230 KV International Transmission Line, San Diego County, California to Tijuana, Mexico, San Diego Gas & Electric Company
Author:
Publisher:
ISBN:
Category : Environmental impact analysis
Languages : en
Pages : 126
Book Description
Publisher:
ISBN:
Category : Environmental impact analysis
Languages : en
Pages : 126
Book Description
Sidney-North Yuma 230-kV Transmission Line Project, Colorado and Nebraska
Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 212
Book Description
This report describes the need for a 230-kV overhead transmission line to supply power from Sidney, Nebraska to eastern Colorado. The alternative scenario compared to construction of the line is No Action. Rejected alternatives include underground lines and different routing paths, with a possible extension to the Sterling area. Both scenarios are evaluated for environmental effects, cost, and consequences for the eastern Colorado region. The proposed route is determined to be the environmentally preferred choice. 120 refs., 6 figs., 13 tabs. (MHB).
Publisher:
ISBN:
Category :
Languages : en
Pages : 212
Book Description
This report describes the need for a 230-kV overhead transmission line to supply power from Sidney, Nebraska to eastern Colorado. The alternative scenario compared to construction of the line is No Action. Rejected alternatives include underground lines and different routing paths, with a possible extension to the Sterling area. Both scenarios are evaluated for environmental effects, cost, and consequences for the eastern Colorado region. The proposed route is determined to be the environmentally preferred choice. 120 refs., 6 figs., 13 tabs. (MHB).
Schultz-Hanford Area Transmission Line Project
The International 345 KV Transmission Line to Highgate, Vermont
Rycevile-Lexington Park 230 KV Transmission Line
Proposed 138 KV Transmission Line Between Jingle Pot Substation and Northfield Substation
Author: Caldwell, L. (Lauren)
Publisher: The Services
ISBN: 9780772632883
Category : Electric lines
Languages : en
Pages : 117
Book Description
This report reviews the potential environmental impacts associated with the proposed alternatives for electrical supply to and the upgrading of the Northfield Substation in Nanaimo, British Columbia. The alternatives studied relate to substation modifications and to the installation of a new line along an existing right-of-way about 3 kilometres long between Northfield and Jingle Pot substations. The report begins with a brief description of existing conditions in the project area and the selection of the recommended alternative. Environmental resources and impacts are then discussed under the following categories: agricultural resources and settlement, vegetation and soils, visual resources and recreation, heritage and archaeological resources, electric and magnetic fields, wildlife, and aquatic and fish resources. Finally, mitigation of impacts is during project implementation is outlined.
Publisher: The Services
ISBN: 9780772632883
Category : Electric lines
Languages : en
Pages : 117
Book Description
This report reviews the potential environmental impacts associated with the proposed alternatives for electrical supply to and the upgrading of the Northfield Substation in Nanaimo, British Columbia. The alternatives studied relate to substation modifications and to the installation of a new line along an existing right-of-way about 3 kilometres long between Northfield and Jingle Pot substations. The report begins with a brief description of existing conditions in the project area and the selection of the recommended alternative. Environmental resources and impacts are then discussed under the following categories: agricultural resources and settlement, vegetation and soils, visual resources and recreation, heritage and archaeological resources, electric and magnetic fields, wildlife, and aquatic and fish resources. Finally, mitigation of impacts is during project implementation is outlined.
Draft Environmental Statement
Author: United States. Bureau of Land Management
Publisher:
ISBN:
Category : Electric lines
Languages : en
Pages : 462
Book Description
Publisher:
ISBN:
Category : Electric lines
Languages : en
Pages : 462
Book Description
Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska
Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 170
Book Description
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).
Publisher:
ISBN:
Category :
Languages : en
Pages : 170
Book Description
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).
North Fresno 115 KV Transmission Line Project
Electricity Transmission Line from Bayswater Power Station to Mount Piper Power Station
Author: Electricity Commission of New South Wales
Publisher:
ISBN: 9780730502418
Category : Electric lines
Languages : en
Pages : 88
Book Description
Publisher:
ISBN: 9780730502418
Category : Electric lines
Languages : en
Pages : 88
Book Description