Performance Evaluation of Low Permeable Concrete Bridge Deck PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Performance Evaluation of Low Permeable Concrete Bridge Deck PDF full book. Access full book title Performance Evaluation of Low Permeable Concrete Bridge Deck by . Download full books in PDF and EPUB format.

Performance Evaluation of Low Permeable Concrete Bridge Deck

Performance Evaluation of Low Permeable Concrete Bridge Deck PDF Author:
Publisher:
ISBN:
Category : Concrete bridges
Languages : en
Pages :

Book Description


Performance Evaluation of Low Permeable Concrete Bridge Deck

Performance Evaluation of Low Permeable Concrete Bridge Deck PDF Author:
Publisher:
ISBN:
Category : Concrete bridges
Languages : en
Pages :

Book Description


Concrete Bridge Deck Performance

Concrete Bridge Deck Performance PDF Author: H. G. Russell
Publisher: Transportation Research Board
ISBN: 0309070112
Category : Bridges
Languages : en
Pages : 188

Book Description
At head of title: National Cooperative Highway Research Program.

Corrosion Protection Performance Evaluation of Low Permeable Concretes in Exposure Specimens

Corrosion Protection Performance Evaluation of Low Permeable Concretes in Exposure Specimens PDF Author: Jerzy Zemajtis
Publisher:
ISBN:
Category : Concrete bridges
Languages : en
Pages : 152

Book Description
The application of a mineral admixture or a combination of a mineral admixture with corrosion inhibitor are the methods used for the corrosion protection for reinforced concrete bridges. The results of a 1.5-year study on evaluation of three concretes with fly ash, slag cement (SC), and silica fume (SF) and one concrete with silica fume and a corrosion inhibitor (SFD) are presented. The specimens were built to simulate four exposure conditions typical for concrete bridges located in the coastal region or inland where deicing salts are used. The exposure conditions were horizontal, vertical, tidal, and immersed zones. The specimens were kept inside the laboratory and were exposed to weekly ponding cycles of 6% sodium chloride solution by weight. In addition, cover depth measurements from 21 bridge decks and chloride data from 3 bridge decks were used, together with laboratory data, in modeling the service lives of investigated corrosion protection methods. The methods used to assess the condition of the specimens included chloride concentration measurements, corrosion potentials, and corrosion rates (3LP). Additionally, visual observations were performed for identification of rust stains and cracking on concrete surfaces. The results of chloride testing indicate that the amount of chlorides present at the bar level is more than sufficient to initiate corrosion. Chloride and rapid permeability data demonstrate that for low permeable (LP) concretes there appears to be significant difference both in a rate of chloride ingress and in the diffusion coefficients in comparison to the controls. Corrosion potentials agree with corrosion rates and suggest the possibility of an active corrosion process development on control specimens during indoor exposure. The structural cracks that were observed in some specimens appeared to have no influence on the corrosion development on the bars in the vicinity of the these cracks. It was concluded that the silicone and duct tape protection was adequate. The cracking, other than structural, appeared to be related to the reinforcing steel corrosion, except the cracks in the horizontal zone of the specimen with slag cement which were probably caused by the subsidence cracking. The least number of cracks was observed on the SF and SFD specimens. Modeling the time as a function of probability of the end of functional service life (EFSL) was presented. It has been shown that the distributions of surface concentrations of chloride ions (CO) and diffusion constants (DC) are key elements in the model. Model predictions show that the LP concretes provide much better level of protection against moisture and chlorides than the A4 concrete alone. Application of a corrosion inhibitor causes an elevation of the chloride threshold resulting in an additional increase in time to EFSL. Recommendations are to continue monitoring until cracking has occurred in all specimens to a greater extent to better estimate the service lives of LP concretes than is presently known in the construction of concrete bridge components in Virginia. The specimens with LP concretes and one control (continuous reinforcement in the legs) should be taken to the Hampton Road North Tunnel Island and placed in the brackish water to a depth of the immersed zone at low tide for further exposure to chloride. The other control (non-continuous reinforcement in the legs) should remain in an outdoor exposure in Southwest Virginia like the Civil Engineering Materials Research Laboratory in Blacksburg, Virginia. Also more field studies are needed to better estimate distributions of surface chloride concentration and diffusion coefficient of Virginia bridge decks, and to confirm predicted times to EFSL for LP concretes.

Non-invasive Permeability Assessment of High-performance Concrete Bridge Deck Mixtures

Non-invasive Permeability Assessment of High-performance Concrete Bridge Deck Mixtures PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Concrete construction methods and practices influence the final in-place quality of concrete. A low permeability concrete mixture does not alone ensure quality in-place concrete. If the concrete mixture is not transported, placed and cured properly, it may not exhibit the desired durability and mechanical properties. This study investigates the in-place permeation properties of low permeability concrete bridge decks mixtures used in the Commonwealth of Virginia. Permeation properties were assessed in both the laboratory and in the field using 4-point Wenner array electrical resistivity, surface air flow (SAF), and chloride ion penetrability (ASTM C 1202-97). Laboratory test specimens consisted of two concrete slabs having dimensions of 280 x 280 x 102-mm (11 x 11 x 4-in) and twelve 102 x 204-mm (4 x 8-in) cylinders per concrete mixture. Specimens were tested at 7, 28 and 91-days. Thirteen cylinder specimens per concrete mixture underwent standard curing in a saturated limewater bath. The simulated field-curing regimes used wet burlap and plastic sheeting for 3 (3B) and 7 days (7B) respectively and was applied to both slabs and cylinder specimens. Slab specimen were tested on finished surface using the SAF at 28 and 91 days, and 4-point electrical resistivity measurements at 1, 3, 7, 14, 28 and 91 days. Compressive strength (CS) tests were conducted at 7 and 28 days. Chloride ion penetrability tests were performed at 7, 28, and 91 days. Statistical analyses were performed to assess the significance of the relationships for the following: Total charge passed and initial current (ASTM C 1202-97); 3B resistivity and 7B resistivity; Slab and cylinder resistivity; Slab resistivity and ASTM C-1202-97 (Total Charge and Initial current); and Surface Air Flow and ASTM C-1202-97.

Evaluation of High Absorptive Materials to Improve Internal Curing of Low Permeability Concrete

Evaluation of High Absorptive Materials to Improve Internal Curing of Low Permeability Concrete PDF Author: Norbert J. Delatte
Publisher:
ISBN:
Category : Bridges
Languages : en
Pages : 148

Book Description
Early age cracking of bridge decks is a national problem, and may substantially reduce service lives and increase maintenance costs. Cracking occurs when the tensile stress exceeds the tensile strength of the concrete. This is a time-dependent phenomenon, since both the stress and strength change at early ages. Moisture loss increases stress (with increasing shrinkage) and impairs strength gain. Internal curing is one method that has been suggested to reduce early age bridge deck cracking, particularly of concretes with low water to cementitious materials (w/cm) ratios. Many state highway agencies have implemented high performance concrete (HPC) for bridge decks. The low permeability of HPC is used to protect reinforcing steel and prevent corrosion. However, if the concrete cracks, then the protection may be greatly diminished. Transverse cracks due to concrete shrinkage allow water and corrosive chemicals to quickly reach the reinforcing steel causing corrosion and shortening the lifespan of the bridge deck. Reducing shrinkage cracking has been the focus of recent research into mitigation strategies. One unintended consequence of the use of high performance concrete may be early-age cracking. Field studies have shown that, in some cases, high performance concrete bridge decks have cracked less than a year after placement. The use of internal curing to reduce autogenous shrinkage was investigated in this study. One method of internal curing was through the use of coarse aggregates with high absorption capacities. Another method discussed is the use of a partial replacement of the fine aggregate with a structural lightweight aggregate with a very high absorption capacity. Bridge deck cracking is also affected by the nominal maximum size coarse aggregate. The effect on shrinkage with increasing size is discussed. ODOT's District 12, located in Northeastern Ohio, found in an investigation of 116 HPC bridge decks placed between 1994 and 2001 that bridges with little or no cracking used coarse aggregate with an absorption> 1 %, while 75 % of bridges with unacceptable cracking used coarse aggregate with absorption 1 %. This report discusses the laboratory investigation of the field results to determine the better ways to prevent bridge deck cracking-- internal curing or paste reduction by using an aggregate blend. The laboratory investigation found that the strongest effect on cracking was due to the replacement of a small maximum size coarse aggregate with an optimized coarse aggregate gradation. Increasing the coarse aggregate absorption level from

Development and Construction of Low-cracking High-performance Concrete (LC-HPC) Bridge Decks

Development and Construction of Low-cracking High-performance Concrete (LC-HPC) Bridge Decks PDF Author: Heather Anne Kirkvold McLeod
Publisher:
ISBN: 9781109337402
Category : Concrete
Languages : en
Pages : 540

Book Description
The development, construction, and evaluation of Low-Cracking High-Performance Concrete (LC-HPC) bridge decks are described based on laboratory test results and experiences gained through the construction of 14 LC-HPC bridge decks. The study is divided into three parts covering (1) an evaluation of the chloride penetration into concrete using long-term salt-ponding tests, (2) a comprehensive discussion of specifications for LC-HPC construction and standard practices in Kansas, and (3) the description of the construction and the preliminary evaluation of LC-HPC bridge decks in Kansas. This report emphasizes the construction process; a companion report (FHWA-KS-09-5) provided a detailed discussion of the influence of material properties on the performance of LC-HPC bridge decks. The first portion of the study involves evaluating the effect of paste content, curing period, water-cement (w/c) ratio, cement type and fineness, mineral admixtures (ground granulated blast furnace slag and silica fume), a shrinkage reducing admixture (SRA), and standard DOT bridge deck mixtures on chloride penetration into solid concrete, tested in accordance with AASHTO T 259. The evaluation includes a total of 33 individual concrete batches and 123 test specimens. The results indicate that for concrete containing only Portland Cement, reductions in paste content result in increased permeability. A reduced paste content and increased w/c ratio result in increased permeability, whereas the presence of mineral admixtures (ground granulated blast furnace slag and silica fume) and longer curing periods result in decreased permeability. Concrete made with medium or coarse ground Type II cement has greater permeability than concrete made with Type I/II cement. It is not clear how the presence of an SRA affects concrete permeability. LC-HPC mixtures have lower permeability than standard DOT mixtures. The second portion of the study describes the specifications for the LC-HPC and Control bridge decks in Kansas. The focus is on the construction methods, including the evolution of the specifications over time. The third portion of the study details the development and construction of 14 LC-HPC and 12 conventional Control bridge decks built in Kansas. The design details, construction experiences, and lessons learned from the LC-HPC bridge decks are described in detail, and an overview of the materials is presented; the design and construction data for each Control deck is provided; and initial crack survey results are evaluated for various construction-related parameters. The results indicate that successful LC-HPC bridge deck construction is repeatable, and that clear and consistent communication between the contractor, owner, and testing personnel is vital for successful construction of LC-HPC decks. Preliminary evaluation of cracking indicates that at early ages, LC-HPC decks are performing better than the Control decks, as well as earlier monolithic decks in Kansas.

Exodermic Bridge Deck Performance Evaluation

Exodermic Bridge Deck Performance Evaluation PDF Author: Irene K. Battaglia
Publisher:
ISBN:
Category : Bridges
Languages : en
Pages : 26

Book Description


Bridge Deck Condition Survey

Bridge Deck Condition Survey PDF Author: John E. LaCroix
Publisher:
ISBN:
Category : Concrete bridges
Languages : en
Pages : 42

Book Description


PRO 37: 5th International RILEM Conference on Cracking in Pavements – Mitigation, Risk Assessment and Prevention

PRO 37: 5th International RILEM Conference on Cracking in Pavements – Mitigation, Risk Assessment and Prevention PDF Author: C. Petit
Publisher: RILEM Publications
ISBN: 9782912143471
Category : Pavements
Languages : en
Pages : 748

Book Description


Evaluation of High Performance Concrete in Four Bridge Decks, as Well as Prestressed Girders for Two Bridges

Evaluation of High Performance Concrete in Four Bridge Decks, as Well as Prestressed Girders for Two Bridges PDF Author: V. Ramakrishnan
Publisher:
ISBN:
Category : Bridges
Languages : en
Pages : 272

Book Description