On-Line X-Ray Inspection of Materials and Structural Components Using Discrete Element X-Ray Detectors for Digital Radiographic and Computed Tomographic Evaluation PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download On-Line X-Ray Inspection of Materials and Structural Components Using Discrete Element X-Ray Detectors for Digital Radiographic and Computed Tomographic Evaluation PDF full book. Access full book title On-Line X-Ray Inspection of Materials and Structural Components Using Discrete Element X-Ray Detectors for Digital Radiographic and Computed Tomographic Evaluation by . Download full books in PDF and EPUB format.

On-Line X-Ray Inspection of Materials and Structural Components Using Discrete Element X-Ray Detectors for Digital Radiographic and Computed Tomographic Evaluation

On-Line X-Ray Inspection of Materials and Structural Components Using Discrete Element X-Ray Detectors for Digital Radiographic and Computed Tomographic Evaluation PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 57

Book Description
This project was designed to study the effectiveness of industrial computed tomography (CT) and digital radiography (DR) as inspection techniques for the evaluation of materials and structural components manufactured on-line. The results indicate that computed tomography is an appropriate technique if speed and cost are not critical considerations. Digital radiography is the faster technique, but provides less information about the material. Limited view tomography (LVT), which is a simplified form of computed tomography, was compared and found to provide a good compromise between computed tomography and digital radiography when a priori knowledge of material structure is available. For some material configurations, it provides virtually complete computed tomography data in a fraction of the time required for full view computed tomography data collection and reconstruction. It offers the greatest potential for the productive cross-sectional characterization of composite materials. (jg).

On-Line X-Ray Inspection of Materials and Structural Components Using Discrete Element X-Ray Detectors for Digital Radiographic and Computed Tomographic Evaluation

On-Line X-Ray Inspection of Materials and Structural Components Using Discrete Element X-Ray Detectors for Digital Radiographic and Computed Tomographic Evaluation PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 57

Book Description
This project was designed to study the effectiveness of industrial computed tomography (CT) and digital radiography (DR) as inspection techniques for the evaluation of materials and structural components manufactured on-line. The results indicate that computed tomography is an appropriate technique if speed and cost are not critical considerations. Digital radiography is the faster technique, but provides less information about the material. Limited view tomography (LVT), which is a simplified form of computed tomography, was compared and found to provide a good compromise between computed tomography and digital radiography when a priori knowledge of material structure is available. For some material configurations, it provides virtually complete computed tomography data in a fraction of the time required for full view computed tomography data collection and reconstruction. It offers the greatest potential for the productive cross-sectional characterization of composite materials. (jg).

Energy Research Abstracts

Energy Research Abstracts PDF Author:
Publisher:
ISBN:
Category : Power resources
Languages : en
Pages : 486

Book Description


Scientific and Technical Aerospace Reports

Scientific and Technical Aerospace Reports PDF Author:
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 318

Book Description


Government Reports Announcements & Index

Government Reports Announcements & Index PDF Author:
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 1178

Book Description


ASM Handbook

ASM Handbook PDF Author: ASM International. Handbook Committee
Publisher: ASM International(OH)
ISBN: 9780871700230
Category : Technology & Engineering
Languages : en
Pages : 824

Book Description
These volumes cover the properties, processing, and applications of metals and nonmetallic engineering materials. They are designed to provide the authoritative information and data necessary for the appropriate selection of materials to meet critical design and performance criteria.

International Aerospace Abstracts

International Aerospace Abstracts PDF Author:
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 1048

Book Description


Government reports annual index

Government reports annual index PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 1308

Book Description


Unique 3-in-1 Research & Development Directory

Unique 3-in-1 Research & Development Directory PDF Author:
Publisher:
ISBN:
Category : Research
Languages : en
Pages : 468

Book Description


Materials Evaluation

Materials Evaluation PDF Author:
Publisher:
ISBN:
Category : Nondestructive testing
Languages : en
Pages : 726

Book Description


DIGITAL RADIOGRAPHY INSPECTION TOOL FOR LARGE ADDITIVELY MANUFACTURED METALLIC COMPONENTS.

DIGITAL RADIOGRAPHY INSPECTION TOOL FOR LARGE ADDITIVELY MANUFACTURED METALLIC COMPONENTS. PDF Author: Brant Stoner
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Through layerwise deposition, additive manufacturing (AM) allows previously unmanufacturable geometries such as organic looking structures and complex internal geometries to be produced. Utilizing these advantages, performance improvements can be gained through techniques such as topology optimization, lattice structures, and part consolidation. Continued improvement of the AM process has shifted the focus of AM to end-use components. Qualification is a key step in enabling AM as an end-use manufacturing method, and the industry has turned to Computed Tomography (CT) as a tool in this process. Although well suited for complex components a few centimeters in size, CT struggles as AM components exceed a meter in length due to limited source energy, restrictive inspection volumes, and excessive data generation. This work proposes Digital Radiography (DR) as a non-destructive inspection method capable of accurately inspecting AM components approaching and exceeding a meter in length. To both expedite the inspection process and make DR a feasible inspection technique, an application, SMART DR was developed to optimize component orientation during the inspection process and provide the probability of detection for flaw sizes of interest prior to manufacturing. By providing this information, SMART DR allows for an inspection plan to be developed or the necessary design changes to be made to ensure that a component can be accurately inspected. SMART DR utilizes a ray trace algorithm for orientation optimization and experimental data along with theoretical relationships to determine a flaws probability of detection. A parallelized back projection algorithm utilizes a virtual representation of the users DR system and a STL representation of the component in question. By projecting the STL facets to the detector and back tracing the X-rays from the detector pixels to the source, the radiographic thickness of the component can be calculated efficiently. To determine the optimal orientation for inspecting the component, the back-projection algorithm is coupled with a genetic optimization scheme to minimize the radiographic thickness of the component. The probability of detection metric is based off of the contrast-to-noise ratio and normalized image unsharpness. Due to limited information on high energy DR in the literature, an experimental plan was created to aid in determining the contrast to noise ratio for source energy between 0.450 Mev to 12 Mev and thicknesses from 25.4 mm to 203.3 mm (1 in. to 8 in.). Square Ti-6Al-4V blocks 76.2 mm (3 in.) wide with cylindrical artificial flaws were used during the experiment. The contrast-to-noise ratio was then measured across each flaw based on ASTM standard E2597 while the normalized image unsharpness was determined based on ASTM standard E2698. Combining these two metrics allow for determining a flaws probability of detection for a wide range of flaw sizes, DR systems, and component thicknesses. Validation was conducted on a 316-stainless steel fin produced using laser based directed energy deposition process. A 0.450 Mev DR system with a 2.5mm spot size and a GE DXR250U-W digital detector array were used during validation. SMART DR produced an optimal orientation that was 40mm thick and predicted that a 0.75 mm diameter flaw with length 0.400mm, .800mm, or 1.60 mm had probability of detection of 91%, 20.7% and 21.7%, respectively. This aligned closely with the smallest detectable flaws on the radiographs of the 316-stainless steel fin, which were 0.508 mm and 0.764 mm. Initial validation results showed that SMART DR is capable of optimizing the DR process and providing accurate probability of detection values within the bounds of the data.