Noninvasive Fluid Detection in Submerged Containers Using Swept Frequency Ultrasonic Technique PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Noninvasive Fluid Detection in Submerged Containers Using Swept Frequency Ultrasonic Technique PDF full book. Access full book title Noninvasive Fluid Detection in Submerged Containers Using Swept Frequency Ultrasonic Technique by Scott MacIntosh. Download full books in PDF and EPUB format.

Noninvasive Fluid Detection in Submerged Containers Using Swept Frequency Ultrasonic Technique

Noninvasive Fluid Detection in Submerged Containers Using Swept Frequency Ultrasonic Technique PDF Author: Scott MacIntosh
Publisher:
ISBN:
Category : Dispersion
Languages : en
Pages : 252

Book Description


Noninvasive Fluid Detection in Submerged Containers Using Swept Frequency Ultrasonic Technique

Noninvasive Fluid Detection in Submerged Containers Using Swept Frequency Ultrasonic Technique PDF Author: Scott MacIntosh
Publisher:
ISBN:
Category : Dispersion
Languages : en
Pages : 252

Book Description


NONINVASIVE, NONCONTACT FLUID DETECTION IN SUBMERGED CONTAINERS USING SWEPT FREQUENCY ULTRASONIC TECHNIQUE.

NONINVASIVE, NONCONTACT FLUID DETECTION IN SUBMERGED CONTAINERS USING SWEPT FREQUENCY ULTRASONIC TECHNIQUE. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Book Description
A noncontact technique has been developed for the remote interrogation of submerged and limited access metal containers for determining the presence of fluid inside, The technique is based on the damping effect of water on the thickness mode resonance of the container wall. A transmitter-receiver pair of piezoelectric transducers is placed at a standoff distance of 5 mm from the container wall with the water outside the container providing ultrasonic coupling medium. The excitation frequency applied to the transmitter is swept between 0.8-4.0M Hz and the receiver transducer detects the signal, in the form of a frequency spectrum, returned from the wall. By analyzing the variation in the observed spectrum, it is straightforward to determine whether the container is fluid or air backed thereby detecting if the container has leaked.

Non-contact Fluid Characterization in Containers Using Ultrasonic Waves

Non-contact Fluid Characterization in Containers Using Ultrasonic Waves PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Apparatus and method for non-contact (stand-off) ultrasonic determination of certain characteristics of fluids in containers or pipes are described. A combination of swept frequency acoustic interferometry (SFAI), wide-bandwidth, air-coupled acoustic transducers, narrowband frequency data acquisition, and data conversion from the frequency domain to the time domain, if required, permits meaningful information to be extracted from such fluids.

Noninvasive Measurement of Acoustic Properties of Fluids Using Ultrasonic Interferometry Technique

Noninvasive Measurement of Acoustic Properties of Fluids Using Ultrasonic Interferometry Technique PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 10

Book Description
A swept-frequency ultrasonic interferometry technique is used for noninvasively determining acoustic properties of fluids inside containers. Measurements over a frequency range 1-15 MHz on six liquid chemicals are presented. Measurements were made with the liquid inside standard rectangular optical glass cells and stainless steel cylindrical shells. A theoretical model based on one-dimensional planar acoustic wave propagation through multi-layered media is employed for the interpretation of the observed resonance (interference) spectrum. Two analytical methods, derived from the transmission model are used for determination of sound speed, sound attenuation coefficient, and density of liquids from the relative amplitude and half-power peak width of the observed resonance peaks. Effects of the container material and geometrical properties, path-length, wall thickness are also studied. This study shows that the interferometry technique and the experimental method developed are capable of accurate determination of sound speed, sound attenuation, and density in fluids completely noninvasively. It is a capable and versatile fluid characterization technique and has many potential NDE applications.

The Journal of the Acoustical Society of America

The Journal of the Acoustical Society of America PDF Author: Acoustical Society of America
Publisher:
ISBN:
Category : Architectural acoustics
Languages : en
Pages : 1636

Book Description


Ultrasonic Densitometer for Non-invasive In-field Detection of Illicit Liquids in Suspect Containers

Ultrasonic Densitometer for Non-invasive In-field Detection of Illicit Liquids in Suspect Containers PDF Author:
Publisher:
ISBN: 9789279193187
Category :
Languages : en
Pages : 72

Book Description
Experiments were undertaken to investigate the feasibility of using propagating ultrasonic waves to find the speed of sound and density of solutions contained in opaque, sealed containers. A portable design is proposed which consists of 3 ultrasonic transducers aligned on a single plane along the surface of a tank. The content is then examined by measuring the time it takes for a signal to reflect off the back wall of the tank and return to another transducer. This time domain response approach delivered a very accurate analysis, with a low spread of results. This report demonstrates that by using this technique, very small changes in density can be observed. The final error in the density has been found to be less than 2%, which is adequate to reliably tell the difference between salt and fresh water.

Non-Invasive Characterization Of A Flowing Multi-Phase Fluid Using Ultrasonic Interferometry

Non-Invasive Characterization Of A Flowing Multi-Phase Fluid Using Ultrasonic Interferometry PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
An apparatus for noninvasively monitoring the flow and/or the composition of a flowing liquid using ultrasound is described. The position of the resonance peaks for a fluid excited by a swept-frequency ultrasonic signal have been found to change frequency both in response to a change in composition and in response to a change in the flow velocity thereof. Additionally, the distance between successive resonance peaks does not change as a function of flow, but rather in response to a change in composition. Thus, a measurement of both parameters (resonance position and resonance spacing), once calibrated, permits the simultaneous determination of flow rate and composition using the apparatus and method of the present invention.

A Swept Frequency Ultrasonic Technique for Distance Measurement in Liquids

A Swept Frequency Ultrasonic Technique for Distance Measurement in Liquids PDF Author: Dan D. Toomey
Publisher:
ISBN:
Category : Liquid level indicators
Languages : en
Pages : 120

Book Description


Noninvasive Characterization of a Flowing Multiphase Fluid Using Ultrasonic Interferometry

Noninvasive Characterization of a Flowing Multiphase Fluid Using Ultrasonic Interferometry PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
An apparatus for noninvasively monitoring the flow and/or the composition of a flowing liquid using ultrasound is described. The position of the resonance peaks for a fluid excited by a swept-frequency ultrasonic signal have been found to change frequency both in response to a change in composition and in response to a change in the flow velocity thereof. Additionally, the distance between successive resonance peaks does not change as a function of flow, but rather in response to a change in composition. Thus, a measurement of both parameters (resonance position and resonance spacing), once calibrated, permits the simultaneous determination of flow rate and composition using the apparatus and method of the present invention.

Noninvasive Method for Determining the Liquid Level and Density Inside of a Container

Noninvasive Method for Determining the Liquid Level and Density Inside of a Container PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Noninvasive method for determining the liquid level and density inside of a container having arbitrary dimension and shape. By generating a flexural acoustic wave in the container shell and measuring the phase difference of the detected flexural wave from that of the originally generated wave a small distance from the generated wave, while moving the generation and detection means through the liquid/vapor interface, this interface can be detected. Both the wave generation and wave detection may be achieved by transducers on the surface of the container. A change in the phase difference over the outer surface of the vessel signifies that a liquid/vapor interface has been crossed, while the magnitude of the phase difference can be related to fluid density immediately opposite the measurement position on the surface of the vessel.