Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet). PDF full book. Access full book title National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet). by . Download full books in PDF and EPUB format.

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet).

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet). PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 2

Book Description
Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent "package" of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet).

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet). PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 2

Book Description
Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent "package" of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

National Grid Deep Energy Retrofit Pilot

National Grid Deep Energy Retrofit Pilot PDF Author:
Publisher:
ISBN:
Category : Architecture and energy conservation
Languages : en
Pages : 155

Book Description
Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance. Evaluation of strategies is structured around the critical control functions of water, airflow, vapor flow, and thermal control. The aim of the research project is to develop guidance that could serve as a foundation for wider adoption of high performance, "deep" retrofit work. The project will identify risk factors endemic to advanced retrofit in the context of the general building type, configuration and vintage encountered in the National Grid DER Pilot. Results for the test homes are based on observation and performance testing of recently completed projects. Additional observation would be needed to fully gauge long-term energy performance, durability, and occupant comfort.

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet)

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet) PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Book Description
Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of majorenclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent 'package' of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects.Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilotparticipants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DERprojects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

Existing Whole-House Solutions Case Study

Existing Whole-House Solutions Case Study PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects, and was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

National Grid Deep Energy Retrofit Pilot Program--Clark Residence

National Grid Deep Energy Retrofit Pilot Program--Clark Residence PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
In this case study, Building Science Corporation partnered with local utility company, National Grid, Massachusetts homes. This project involved the renovation of a 18th century Cape-style building and achieved a super-insulated enclosure (R-35 walls, R-50+ roof, R-20+ foundation), extensive water management improvements, high-efficiency water heater, and state-of-the-art ventilation.

Performance results for Massachusetts and Rhode Island deep energy retrofit pilot community

Performance results for Massachusetts and Rhode Island deep energy retrofit pilot community PDF Author: C. Gates
Publisher:
ISBN:
Category : Dwellings
Languages : en
Pages : 95

Book Description
Between December, 2009 and December, 2012, 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average.

Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program

Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program PDF Author: C. Gates
Publisher:
ISBN:
Category : Architecture and energy conservation
Languages : en
Pages : 158

Book Description
This research project evaluates post-retrofit performance measurements, energy use data and construction costs for 13 projects that participated in the National Grid Deep Energy Retrofit Pilot program. The projects implemented a package of measures defined by performance targets for building enclosure components and building enclosure air tightness. Nearly all of the homes reached a post-retrofit air tightness result of 1.5 ACH 50. Homes that used the chainsaw retrofit technique along with roof insulation, and wall insulation applied to the exterior had the best air tightness results and the lowest heating and cooling source energy use. Analysis of measure costs and project objectives yielded a categorization of costs relative to energy performance objectives. On average about 1/2 of the energy-related measure costs correspond primarily to energy-related objectives, and 20% of energy-related measure costs relate primarily to non-energy objectives.

Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program

Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 169

Book Description
This research project evaluates post-retrofit performance measurements, energy use data and construction costs for 13 projects that participated in the National Grid Deep Energy Retrofit Pilot program. The projects implemented a package of measures defined by performance targets for building enclosure components and building enclosure air tightness. Nearly all of the homes reached a post-retrofit air tightness result of 1.5 ACH 50. Homes that used the chainsaw retrofit technique along with roof insulation, and wall insulation applied to the exterior had the best air tightness results and the lowest heating and cooling source energy use. Analysis of measure costs and project objectives yielded a categorization of costs relative to energy performance objectives. On average about 1/2 of the energy-related measure costs correspond primarily to energy-related objectives, and 20% of energy-related measure costs relate primarily to non-energy objectives.

Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Book Description
Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of majorenclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent 'package' of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects.Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilotparticipants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DERprojects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes

Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description