Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download National Dam Safety Program. Riss Lake Dam (MO 20128), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report PDF full book. Access full book title National Dam Safety Program. Riss Lake Dam (MO 20128), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report by Harold P. Hoskins. Download full books in PDF and EPUB format.

National Dam Safety Program. Riss Lake Dam (MO 20128), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report

National Dam Safety Program. Riss Lake Dam (MO 20128), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report PDF Author: Harold P. Hoskins
Publisher:
ISBN:
Category :
Languages : en
Pages : 45

Book Description
Riss Lake Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillway will not pass a 100-year flood (flood having a one percent chance of being exceeded in any year). The spillway will pass 12% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

National Dam Safety Program. Riss Lake Dam (MO 20128), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report

National Dam Safety Program. Riss Lake Dam (MO 20128), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report PDF Author: Harold P. Hoskins
Publisher:
ISBN:
Category :
Languages : en
Pages : 45

Book Description
Riss Lake Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillway will not pass a 100-year flood (flood having a one percent chance of being exceeded in any year). The spillway will pass 12% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

Missouri, Missouri-Kansas City Basin, Riss Lake Dam, Jackson County, Missouri Phase 1 Inspection Report, National Dam Safety Program

Missouri, Missouri-Kansas City Basin, Riss Lake Dam, Jackson County, Missouri Phase 1 Inspection Report, National Dam Safety Program PDF Author: United States. Army. Corps of Engineers. St. Louis District
Publisher:
ISBN:
Category : Dams
Languages : en
Pages : 96

Book Description


National Dam Safety Program. Riss Lake Dam (MO 10926), Missouri - Kansas City Basin, Platte County, Missouri. Phase I Inspection Report

National Dam Safety Program. Riss Lake Dam (MO 10926), Missouri - Kansas City Basin, Platte County, Missouri. Phase I Inspection Report PDF Author: Paul R. Zaman
Publisher:
ISBN:
Category :
Languages : en
Pages : 52

Book Description
Riss Lake Dam was inspected to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates the spillway does not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillway will not pass the probable maximum flood without overtopping but will pass 90 percent of the probable maximum flood, which is greater than the estimated 100-year flood. The spillway design flood recommended by the guidelines is 100 percent of the probable maximum flood. The probable maximum flood is defined as the flood discharge which may be expected from the most severe combination of critical meteorologic and hydrologic conditions which are reasonably possible in the region. Deficiencies visually observed by the inspection team were erosion of the upstream face due to wave action, ponded water on the dam crest due to poor drainage of rainwater, trees and brush growing on the embankment, animal burrows, and seepage at several locations below the dam.

Technical Abstract Bulletin

Technical Abstract Bulletin PDF Author:
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 206

Book Description


National Dam Safety Program. Christiansen Lake Dam (MO 20145), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report

National Dam Safety Program. Christiansen Lake Dam (MO 20145), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report PDF Author: Paul R. Zaman
Publisher:
ISBN:
Category :
Languages : en
Pages : 59

Book Description
The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Inspection and evaluation indicated the spillways do not meet the criteria set forth in the guidelines. The spillways will not pass the probable maximum flood without overtopping but will pass 20 percent of the probable maximum flood. The spillways will pass the flood which has a one percent probability of occurrence in any given year (100-year flood). The spillway design flood recommended by the guidelines is 50 to 100 percent of the probable maximum flood. Considering the hazard zone, the spillway design flood should be 100 percent of the probable maximum flood. The probable maximum flood is defined as the flood discharge which may be expected from the most severe combination of critical meteorologic and hydrologic conditions which are reasonably possible in the region. Based on visual observations, this dam appears to be in fair condition.

National Dam Safety Program. Terrace Lake Dam (MO 20167), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report

National Dam Safety Program. Terrace Lake Dam (MO 20167), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report PDF Author: D. P. Gupta
Publisher:
ISBN:
Category :
Languages : en
Pages : 39

Book Description
This report was prepared under the National Program of Inspection of Non-Federal Dams. This report assesses the general condition of the dam with respect to safety, based on available data and on visual inspection, to determine if the dam poses hazards to human life or property. (Author).

National Dam Safety Program. Union Lake Dam (MO 30225), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report

National Dam Safety Program. Union Lake Dam (MO 30225), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report PDF Author: Edwin R. Burton
Publisher:
ISBN:
Category :
Languages : en
Pages : 106

Book Description
Union Lake Dam was inspected by a team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates the spillways do not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillways will not pass the probable maximum flood without overtopping but will pass 10 percent of the probable maximum flood. The spillways will not pass the flood which has a one percent chance of occurrence in any given year (100-year flood), but will pass the flood with a 10 percent change of occurrence (10-year flood). The spillway design flood recommended by the guidelines is 50 to 100 percent of the probable maximum flood. Considering the damage zone, the spillway design flood should be 100 percent of the probable maximum flood.

National Dam Safety Program. Unity Lake Number 1 Dam (MO 20039), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report

National Dam Safety Program. Unity Lake Number 1 Dam (MO 20039), Missouri - Kansas City Basin, Jackson County, Missouri. Phase I Inspection Report PDF Author: Paul R. Zaman
Publisher:
ISBN:
Category :
Languages : en
Pages : 42

Book Description
The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. This dam is classified as an intermediate size dam with a high downstream hazard potential. The inspection and evaluation indicates the spillway does not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillway will pass 50 percent of the probable maximum flood without overtopping. Deficiencies visually observed by the inspection team were minor amounts of seepage at random slab, joints and in abutment drains, minor concrete spalling on the spillways downstream surface, exposed reinforcing steel on vertical supports, and the absence of containment walls on the spillway.

National Dam Safety Program. Spring Lake Dam (MO 11122), Missouri - Kansas City Basin, Clinton County, Missouri. Phase I Inspection Report

National Dam Safety Program. Spring Lake Dam (MO 11122), Missouri - Kansas City Basin, Clinton County, Missouri. Phase I Inspection Report PDF Author: Rey S. Decker
Publisher:
ISBN:
Category :
Languages : en
Pages : 74

Book Description
The purpose of the inspection was to make an assessment of the general conditions of the dam with respect to safety, based upon available data visual inspection, in order to determine if the dam poses hazards to human life or property. The inspection and evaluation indicate that the spillways do not meet the minimum criteria set forth in the recommended guidelines for an intermediate dam having a high hazard potential. The Probable Maximum Flood is the appropriate spillway design flood. The spillway will pass the 100-year flood (a flood having a 1 percent probability of being exceeded in any year) without overtopping the dam. The spillways will pass 22 percent of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

National Dam Safety Program. Spring Fork Lake Dam (MO 30152), Missouri - Kansas City Basin, Pettis County, Missouri. Phase I Inspection Report

National Dam Safety Program. Spring Fork Lake Dam (MO 30152), Missouri - Kansas City Basin, Pettis County, Missouri. Phase I Inspection Report PDF Author: C. L. Metzler
Publisher:
ISBN:
Category :
Languages : en
Pages : 55

Book Description
The purpose of this inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. The inspection and evaluation indicates the spillways do not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillways will pass 55 percent of the probable maximum flood, which is greater than the 100-year flood, without over topping the dam. The spillway design flood recommended by the guidelines is the probable maximum flood. The probable maximum flood is defined as the flood discharge that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region. Deficiencies visually observed by the inspection team were minor seepage through the spillway weir wall, erosion on the upstream embankment, minor deterioration of the concrete weir, separation of riprap, brush growth on both faces of the structure, and a slide area on the downstream face. There were no observed deficiencies or conditions existing at the time of the inspection which indicated an immediate safety hazard. Future corrective action and regular maintenance will be required to correct or control the described deficiencies.