Measurements on the Thermal Dilatation of Glass at High Temperatures (Classic Reprint) PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Measurements on the Thermal Dilatation of Glass at High Temperatures (Classic Reprint) PDF full book. Access full book title Measurements on the Thermal Dilatation of Glass at High Temperatures (Classic Reprint) by C. G. Peters. Download full books in PDF and EPUB format.

Measurements on the Thermal Dilatation of Glass at High Temperatures (Classic Reprint)

Measurements on the Thermal Dilatation of Glass at High Temperatures (Classic Reprint) PDF Author: C. G. Peters
Publisher: Forgotten Books
ISBN: 9780266898191
Category : Science
Languages : en
Pages : 44

Book Description
Excerpt from Measurements on the Thermal Dilatation of Glass at High Temperatures Dorsey11 measured the expansion coefficient of glass tubing Of unknown chemical composition between 20 and I 70° C. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

Measurements on the Thermal Dilatation of Glass at High Temperatures (Classic Reprint)

Measurements on the Thermal Dilatation of Glass at High Temperatures (Classic Reprint) PDF Author: C. G. Peters
Publisher: Forgotten Books
ISBN: 9780266898191
Category : Science
Languages : en
Pages : 44

Book Description
Excerpt from Measurements on the Thermal Dilatation of Glass at High Temperatures Dorsey11 measured the expansion coefficient of glass tubing Of unknown chemical composition between 20 and I 70° C. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

Measurements of the Thermal Dilatation of Glass at High Temperatures

Measurements of the Thermal Dilatation of Glass at High Temperatures PDF Author: Chauncey George Peters
Publisher:
ISBN:
Category : Expansion (Heat).
Languages : en
Pages : 40

Book Description


Measurements on the Thermal Dilation of Glass at High Temperatures

Measurements on the Thermal Dilation of Glass at High Temperatures PDF Author: Chauncey George Peters
Publisher:
ISBN:
Category : Glass
Languages : en
Pages : 0

Book Description


Measurements of the Index of Refraction of Glass at High Temperatures (Classic Reprint)

Measurements of the Index of Refraction of Glass at High Temperatures (Classic Reprint) PDF Author: C. G. Peters
Publisher: Forgotten Books
ISBN: 9781528523462
Category : Science
Languages : en
Pages : 32

Book Description
Excerpt from Measurements of the Index of Refraction of Glass at High Temperatures Measurements of the index of refraction of glass have usually been made' at room temperature with the prism spectrometer. The index [1 was then computed by the equation. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

Measurements on the Thermal Dilatation of Glass at High Temperatures Volume Scientific Papers of the Bureau of Standards, Vol. 16, 449-487 (1920) Scientific Paper 393 (S393)

Measurements on the Thermal Dilatation of Glass at High Temperatures Volume Scientific Papers of the Bureau of Standards, Vol. 16, 449-487 (1920) Scientific Paper 393 (S393) PDF Author: C. G. Cragoe C. H. Peters
Publisher: Palala Press
ISBN: 9781354073964
Category :
Languages : en
Pages : 46

Book Description
This work has been selected by scholars as being culturally important, and is part of the knowledge base of civilization as we know it. This work was reproduced from the original artifact, and remains as true to the original work as possible. Therefore, you will see the original copyright references, library stamps (as most of these works have been housed in our most important libraries around the world), and other notations in the work.This work is in the public domain in the United States of America, and possibly other nations. Within the United States, you may freely copy and distribute this work, as no entity (individual or corporate) has a copyright on the body of the work.As a reproduction of a historical artifact, this work may contain missing or blurred pages, poor pictures, errant marks, etc. Scholars believe, and we concur, that this work is important enough to be preserved, reproduced, and made generally available to the public. We appreciate your support of the preservation process, and thank you for being an important part of keeping this knowledge alive and relevant.

Measurements on the thermal dilatation of glass at high temperatures

Measurements on the thermal dilatation of glass at high temperatures PDF Author: Chauncey George Peters
Publisher:
ISBN:
Category : Expansion (Heat)
Languages : en
Pages : 43

Book Description


Measurements on the Thermal Dilatation of Glass at High Temperatures

Measurements on the Thermal Dilatation of Glass at High Temperatures PDF Author: C. G. Peters
Publisher: BiblioGov
ISBN: 9781289215026
Category :
Languages : en
Pages : 46

Book Description
In 1901 the National Bureau of Standards (NBS) was founded to provide standard weights and measures and to be the national physical laboratory for the United States of America. The NBS conducted a lot of research in the fields of science and technology which were reported as "Scientific Papers." In 1988 the NBS became what we know now; the National Institute of Standards and Technology (NIST). This is one of those documents written by employees of the NBS.

The Interference Method of Measuring Thermal Expansion (Classic Reprint)

The Interference Method of Measuring Thermal Expansion (Classic Reprint) PDF Author: George E. Merritt
Publisher: Forgotten Books
ISBN: 9780266801337
Category : Science
Languages : en
Pages : 24

Book Description
Excerpt from The Interference Method of Measuring Thermal Expansion Since materials differ greatly in the rate with which they reach equilibrium, an investigator attempting to obtain measurements! Under equilibrium conditions should give careful consideration to this rate at the temperatures involved. For certain kinds of work it is the practice to hold the specimen for a sufficient length of time at each temperature where measurements are to be taken. Cases have occurred in this laboratory Where equilibrium conditions were not reached even after several hours. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

Measurements on the Thermal Expansion of Fused Silica (Classic Reprint)

Measurements on the Thermal Expansion of Fused Silica (Classic Reprint) PDF Author: Wilmer Souder
Publisher: Forgotten Books
ISBN: 9780428928629
Category : Technology & Engineering
Languages : en
Pages : 34

Book Description
Excerpt from Measurements on the Thermal Expansion of Fused Silica The vertical position wires are illuminated by 10-watt mazda frosted spherical lamp bul'os. Resistances in the lamp circuit are used to reduce the illumination to a satisfactory intensity. By placing parallel spider lines in the reticle of the microscope to caliper the position wires. An excellent arrangement for high-precision measurements is secured. The air furnace in Figure 2 has external control rheostats for each side and end of the heating chamber. The external heat loss from these rheostats is reduced by using a transformer for the lower temperature tests. With all furnaces it is essential that the horizontal condition of the specimen shall not change during the test. A further precaution. For the bath furnace requires that the readings be made at a known distance above the end of the specimen and that the exact ratio of distances - level of observation to upper support of wires and end of specimens to upper support of wires - be known and maintained. Specimens which have a tendency to warp on heating can be placed in a glass tube or between plates. Tests on such specimens are not considered to be satisfactory. The change in length of materials incident to the heat treatment of the test is recorded as the difference between the room temperature observations before and after the test. Verification of this change is afforded by readings of a micrometer caliper used to secure the length of the specimen before mounting in, and after removal from, the furnace. This value is often of importance in verifying an imperfect annealing of the specimen or establishing the percentage growth or shrinkage due to chemical changes. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

High-Temperature Measurements (Classic Reprint)

High-Temperature Measurements (Classic Reprint) PDF Author: H. Le Chatelier
Publisher:
ISBN: 9781331944010
Category : Science
Languages : en
Pages : 264

Book Description
Excerpt from High-Temperature Measurements The measurement of high temperatures was considered for a long time to be a very difficult operation and of a very uncertain precision. There were cited with admiration a half-dozen determinations seeming to merit some confidence. During the last few years the question has made considerable progress, and we possess to-day several sufficiently precise pyrometers whose usage is rapidly spreading among scientific and industrial laboratories. Before describing them, perhaps it will not be useless to indicate the services that they may render to science and to industry, by giving a brief summary of similar services that they have already rendered. Among the researches in pure science which result from the new methods of the measurement of high temperatures, of primary importance are the masterly investigations of Osmond on the allotropic transformations of iron. After having precisely determined the nature of the phenomenon of recalescence, noted for the first time by Gore and Bartlett, Osmond discovered in iron two similar transformations: one, taking place in the neighborhood of 750, corresponds to the loss of magnetic properties, and the other, at about 900, is accompanied by a considerable evolution of heat. A third transformation of iron near 1300 has been discovered since by Ball. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works."