Measurement of the Current Density Profile in the Alcator C Tokamak Using Lithium Pellets PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Measurement of the Current Density Profile in the Alcator C Tokamak Using Lithium Pellets PDF full book. Access full book title Measurement of the Current Density Profile in the Alcator C Tokamak Using Lithium Pellets by Earl S. Marmar. Download full books in PDF and EPUB format.

Measurement of the Current Density Profile in the Alcator C Tokamak Using Lithium Pellets

Measurement of the Current Density Profile in the Alcator C Tokamak Using Lithium Pellets PDF Author: Earl S. Marmar
Publisher:
ISBN:
Category :
Languages : en
Pages : 17

Book Description


Measurement of the Current Density Profile in the Alcator C Tokamak Using Lithium Pellets

Measurement of the Current Density Profile in the Alcator C Tokamak Using Lithium Pellets PDF Author: Earl S. Marmar
Publisher:
ISBN:
Category :
Languages : en
Pages : 17

Book Description


Lithium Pellet Injection Experiments on the Alcator C-Mod Tokamak

Lithium Pellet Injection Experiments on the Alcator C-Mod Tokamak PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 131

Book Description
A pellet enhanced performance mode, showing significantly reduced core transport, is regularly obtained after the injection of deeply penetrating lithium pellets into Alcator C-Mod discharges. These transient modes, which typically persist about two energy confinement times, are characterized by a steep pressure gradient (l{sub p} (less-than or equal to) a/5) in the inner third of the plasma, indicating the presence of an internal transport barrier. Inside this barrier, particle and energy diffusivities are greatly reduced, with ion thermal diffusivity dropping to near neoclassical values. Meanwhile, the global energy confinement time shows a 30% improvement over ITER89-P L-mode scaling. The addition of ICRF auxiliary heating shortly after the pellet injection leads to high fusion reactivity with neutron rates enhanced by an order of magnitude over L-mode discharges with similar input powers. A diagnostic system for measuring equilibrium current density profiles of tokamak plasmas, employing high speed lithium pellets, is also presented. Because ions are confined to move along field lines, imaging the Li emission from the toroidally extended pellet ablation cloud gives the direction of the magnetic field. To convert from temporal to radial measurements, the 3-D trajectory of the pellet is determined using a stereoscopic tracking system. These measurements, along with external magnetic measurements, are used to solve the Grad-Shafranov equation for the magnetic equilibrium of the plasma. This diagnostic is used to determine the current density profile of PEP modes by injection of a second pellet during the period of good confinement. This measurement indicates that a region of reversed magnetic shear exists at the plasma core. This current density profile is consistent with TRANSP calculations for the bootstrap current created by the pressure gradient. MHD stability analysis indicates that these plasmas are near the n = (infinity) and the n = 1 marginal stability limits.

Energy Research Abstracts

Energy Research Abstracts PDF Author:
Publisher:
ISBN:
Category : Power resources
Languages : en
Pages : 548

Book Description


Scientific and Technical Aerospace Reports

Scientific and Technical Aerospace Reports PDF Author:
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 704

Book Description


Lithium Pellet Injection Experiments on the Alcator C-Mod Tokamak

Lithium Pellet Injection Experiments on the Alcator C-Mod Tokamak PDF Author: Darren Thomas Garnier
Publisher:
ISBN:
Category :
Languages : en
Pages : 132

Book Description


Fusion Science and Technology

Fusion Science and Technology PDF Author:
Publisher:
ISBN:
Category : Fusion reactors
Languages : en
Pages : 808

Book Description


Proceedings

Proceedings PDF Author:
Publisher:
ISBN:
Category : Controlled fusion
Languages : en
Pages : 862

Book Description


Density Fluctuations Following Fuel Pellet Injection on the Alcator C Tokamak

Density Fluctuations Following Fuel Pellet Injection on the Alcator C Tokamak PDF Author: Jeffery Kurt Parker
Publisher:
ISBN:
Category :
Languages : en
Pages : 122

Book Description


Lower Hybrid Current Drive on Alcator C-Mod

Lower Hybrid Current Drive on Alcator C-Mod PDF Author: Robert Thomas Mumgaard
Publisher:
ISBN:
Category :
Languages : en
Pages : 349

Book Description
Lower Hybrid Current Drive (LHCD) is a promising technique to sustain tokamak plasmas and provide control over the current profile--two important capabilities required for the development of tokamak fusion reactors. Upgraded measurement capabilities on the Alcator C-Mod Tokamak create a unique opportunity to study the plasma's toroidal electric current profile at magnetic fields, plasma densities, and magnetic geometries anticipated in future reactors in stationary discharges dominated by lhcd. The Motional Stark Effect (MSE) diagnostic uses polarized light to infer the plasma's internal current profile. The MSE diagnostic deployed on the Alcator C-Mod Tokamak previously experienced unacceptable calibration drift and sensitivity to partially-polarized background light that limited its ability to measure magnetic field pitch-angles. A comprehensive analytic study of the origin of polarization angle errors in MSE diagnostics and an experimental study using a robotic calibration system were conducted. Insight from this study guided the fabrication and installation of a first-of-a-kind in-situ calibration system for MSE diagnostics--a long sought capability-- and the development of thermal isolation schemes for the periscope. An experimental study of the effect of partially polarized background light identified this as a significant source of systematic error. Partial-polarization upon reflection was identified as the mechanism that leads to polarized light in a tokamak. Visible bremsstrahlung, divertor emission, and blackbody emission were identified as the dominant sources of light. A new technique, MSE multi-spectral line polarization (MSE-MSLP), was developed to measure the polarization on a single sight line in multiple wavelengths simultaneously using a high-throughput polarization polychromator. Wavelength-interpolation of the background light polarization utilizing this hardware decreases the error from background subtraction by a factor of 5-10 relative to time-interpolation, drastically improving the measurement quality while eliminating the need for neutral beam pulsing. The method also allows for simultaneous measurement of multiple polarized transitions within the Stark multiplet. The upgraded MSE diagnostic was used to measure the magnetic field pitch angle profile in plasmas with some or all of the plasma current driven by lhcd. Measurements were made across a range of single-parameter scans: lhcd power, loop voltage, plasma density, plasma current, and launched n// spectrum. The current profile is observed to broaden during lhcd, but consistently has significant on-axis current density, even in fully non-inductive plasmas. The current profile and hard x-ray (HXR) profiles are observed to be most sensitive to plasma current, with higher current yielding broader profiles. The current and HXR profiles as well as global current-drive efficiency are insensitive to changes in n// or loop voltage. Numerical simulations by the ray-tracing Fokker-Planck GENRAY/CQL3D code reproduce the total measured current in non-inductive conditions but fail to accurately predict the current and HXR profiles; the simulations consistently predict more current drive in the outer half of the plasma than is observed. This leads to a flattening of the HXR profile compared to the experimental profiles. These qualitative discrepancies persist across the range of plasma parameters scanned. Varying code inputs within their measurement uncertainties and adding experimentally-constrained levels of fast-electron diffusion do not reconcile profile discrepancies. Some qualitative profile trends in single parameter scans are reproduced by the simulations including broadening of profiles at higher current, and a weak dependence on the launched n//spectrum. However, HXR profile self-similarity across different densities and powers is not reproduced. These new comparisons between profile measurements and simulation suggest that the simulations are missing important physics in this operational regime.

Physics Briefs

Physics Briefs PDF Author:
Publisher:
ISBN:
Category : Physics
Languages : en
Pages : 820

Book Description