New Enhanced Sensitivity Infrared Laser Spectroscopy Techniques Applied to Reactive Plasmas and Trace Gas Detection PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download New Enhanced Sensitivity Infrared Laser Spectroscopy Techniques Applied to Reactive Plasmas and Trace Gas Detection PDF full book. Access full book title New Enhanced Sensitivity Infrared Laser Spectroscopy Techniques Applied to Reactive Plasmas and Trace Gas Detection by Stefan Welzel. Download full books in PDF and EPUB format.

New Enhanced Sensitivity Infrared Laser Spectroscopy Techniques Applied to Reactive Plasmas and Trace Gas Detection

New Enhanced Sensitivity Infrared Laser Spectroscopy Techniques Applied to Reactive Plasmas and Trace Gas Detection PDF Author: Stefan Welzel
Publisher: Logos Verlag Berlin GmbH
ISBN: 3832523456
Category : Science
Languages : en
Pages : 198

Book Description
Infrared laser absorption spectroscopy (IRLAS) employing both tuneable diode and quantum cascade lasers (TDLs, QCLs) has been applied with both high sensitivity and high time resolution to plasma diagnostics and trace gas measurements. TDLAS combined with a conventional White type multiple pass cell was used to detect up to 13 constituent molecular species in low pressure Ar/H2/N2/O2 and Ar/CH4/N2/O2 microwave discharges, among them the main products such as H2O, NH3, NO and CO, HCN respectively. The hydroxyl radical has been measured in the mid infrared (MIR) spectral range in-situ in both plasmas yielding number densities of between 1011 ... 1012 cm-3. Strong indications of surface dominated formation of either NH3 or N2O and NO were found in the H2-N2-O2 system. In methane containing plasmas a transition between deposition and etching conditions and generally an incomplete oxidation of the precursor were observed. The application of QCLs for IRLAS under low pressure conditions employing the most common tuning approaches has been investigated in detail. A new method of analysing absorption features quantitatively when the rapid passage effect is present is proposed. If power saturation is negligible, integrating the undisturbed half of the line profile yields accurate number densities without calibrating the system. By means of a time resolved analysis of individual chirped QCL pulses the main reasons for increased effective laser line widths could be identified. Apart from the well-known frequency down chirp non-linear absorption phenomena and bandwidth limitations of the detection system may significantly degrade the performance and accuracy of inter pulse spectrometers. The minimum analogue bandwidth of the entire system should normally not fall below 250 MHz. QCLAS using pulsed lasers has been used for highly time resolved measurements in reactive plasmas for the first time enabling a time resolution down to about 100 ns to be achieved. A temperature increase of typically less than 50 K has been established for pulsed DC discharges containing Ar/N2 and traces of NO. The main NO production and depletion reactions have been identified from a comparison of model calculations and time resolved measurements in plasma pulses of up to 100 ms. Considerable NO struction is observed after 5 ... 10 ms due to the impact of N atoms. Finally, thermoelectrically cooled pulsed and continuous wave (cw) QCLs have been employed for high finesse cavity absorption spectroscopy in the MIR. Cavity ring down spectroscopy (CRDS) has been performed with pulsed QCLs and was found to be limited by the intrinsic frequency chirp of the laser suppressing an efficient intensity build-up inside the cavity. Consequently the accuracy and advantage of an absolute internal absorption calibration is not achievable. A room temperature cw QCL was used in a complementary cavity enhanced absorption spectroscopy (CEAS) configuration which was equipped with different cavities of up to 1.3 m length. This spectrometer yielded path lengths of up to 4 km and a noise equivalent absorption down to 4 x 10-8 cm-1Hz-1/2. The corresponding molecular concentration detection limit (e.g. for CH4, N2O and C2H2 at 1303 cm-1/7.66 Aem) was generally below 1 x 1010 cm-3 for 1 s integration times and one order of magnitude less for 30 s integration times. The main limiting factor for achieving even higher sensitivity is the residual mode noise of the cavity. Employing a 0.5 m long cavity the achieved sensitivity was good enough for the selective measurement of trace atmospheric constituents at 2.2 mbar.

New Enhanced Sensitivity Infrared Laser Spectroscopy Techniques Applied to Reactive Plasmas and Trace Gas Detection

New Enhanced Sensitivity Infrared Laser Spectroscopy Techniques Applied to Reactive Plasmas and Trace Gas Detection PDF Author: Stefan Welzel
Publisher: Logos Verlag Berlin GmbH
ISBN: 3832523456
Category : Science
Languages : en
Pages : 198

Book Description
Infrared laser absorption spectroscopy (IRLAS) employing both tuneable diode and quantum cascade lasers (TDLs, QCLs) has been applied with both high sensitivity and high time resolution to plasma diagnostics and trace gas measurements. TDLAS combined with a conventional White type multiple pass cell was used to detect up to 13 constituent molecular species in low pressure Ar/H2/N2/O2 and Ar/CH4/N2/O2 microwave discharges, among them the main products such as H2O, NH3, NO and CO, HCN respectively. The hydroxyl radical has been measured in the mid infrared (MIR) spectral range in-situ in both plasmas yielding number densities of between 1011 ... 1012 cm-3. Strong indications of surface dominated formation of either NH3 or N2O and NO were found in the H2-N2-O2 system. In methane containing plasmas a transition between deposition and etching conditions and generally an incomplete oxidation of the precursor were observed. The application of QCLs for IRLAS under low pressure conditions employing the most common tuning approaches has been investigated in detail. A new method of analysing absorption features quantitatively when the rapid passage effect is present is proposed. If power saturation is negligible, integrating the undisturbed half of the line profile yields accurate number densities without calibrating the system. By means of a time resolved analysis of individual chirped QCL pulses the main reasons for increased effective laser line widths could be identified. Apart from the well-known frequency down chirp non-linear absorption phenomena and bandwidth limitations of the detection system may significantly degrade the performance and accuracy of inter pulse spectrometers. The minimum analogue bandwidth of the entire system should normally not fall below 250 MHz. QCLAS using pulsed lasers has been used for highly time resolved measurements in reactive plasmas for the first time enabling a time resolution down to about 100 ns to be achieved. A temperature increase of typically less than 50 K has been established for pulsed DC discharges containing Ar/N2 and traces of NO. The main NO production and depletion reactions have been identified from a comparison of model calculations and time resolved measurements in plasma pulses of up to 100 ms. Considerable NO struction is observed after 5 ... 10 ms due to the impact of N atoms. Finally, thermoelectrically cooled pulsed and continuous wave (cw) QCLs have been employed for high finesse cavity absorption spectroscopy in the MIR. Cavity ring down spectroscopy (CRDS) has been performed with pulsed QCLs and was found to be limited by the intrinsic frequency chirp of the laser suppressing an efficient intensity build-up inside the cavity. Consequently the accuracy and advantage of an absolute internal absorption calibration is not achievable. A room temperature cw QCL was used in a complementary cavity enhanced absorption spectroscopy (CEAS) configuration which was equipped with different cavities of up to 1.3 m length. This spectrometer yielded path lengths of up to 4 km and a noise equivalent absorption down to 4 x 10-8 cm-1Hz-1/2. The corresponding molecular concentration detection limit (e.g. for CH4, N2O and C2H2 at 1303 cm-1/7.66 Aem) was generally below 1 x 1010 cm-3 for 1 s integration times and one order of magnitude less for 30 s integration times. The main limiting factor for achieving even higher sensitivity is the residual mode noise of the cavity. Employing a 0.5 m long cavity the achieved sensitivity was good enough for the selective measurement of trace atmospheric constituents at 2.2 mbar.

Introduction to Plasma Spectroscopy

Introduction to Plasma Spectroscopy PDF Author: Hans-Joachim Kunze
Publisher: Springer Science & Business Media
ISBN: 3642022332
Category : Science
Languages : en
Pages : 242

Book Description
Although based on lectures given for graduate students and postgraduates starting in plasma physics, this concise introduction to the fundamental processes and tools is as well directed at established researchers who are newcomers to spectroscopy and seek quick access to the diagnostics of plasmas ranging from low- to high-density technical systems at low temperatures, as well as from low- to high-density hot plasmas. Basic ideas and fundamental concepts are introduced as well as typical instrumentation from the X-ray to the infrared spectral regions. Examples, techniques and methods illustrate the possibilities. This book directly addresses the experimentalist who actually has to carry out the experiments and their interpretation. For that reason about half of the book is devoted to experimental problems, the instrumentation, components, detectors and calibration.

Proceedings of the Tenth International Conference on Chemical Vapor Deposition, 1987

Proceedings of the Tenth International Conference on Chemical Vapor Deposition, 1987 PDF Author: Electrochemical Society. High Temperature Materials Division
Publisher:
ISBN:
Category : Vapor-plating
Languages : en
Pages : 1296

Book Description


Plasma Spectroscopy

Plasma Spectroscopy PDF Author: Takashi Fujimoto
Publisher: Clarendon Press
ISBN: 0191523895
Category : Science
Languages : en
Pages : 300

Book Description
This book focuses on the characteristics of optical radiation, or a spectrum, emitted by various plasmas. In plasma, the same atomic species can produce quite different spectra, or colours, depending on the nature of the plasma. This book gives a theoretical framework by which a particular spectrum can be interpreted correctly and coherently. The uniqueness of the book lies in its comprehensive treatment of the intensity distribution of spectral lines and the population density distribution among the atomic levels in plasmas. It is intended to provide beginners with a good perspective of the field, laying out the physics in an extremely clear manner and starting from an elementary level. A useful feature of the book is the asterisked sections and chapters which can be skipped by readers who only wish to gain a quick and basic introduction to plasma spectroscopy. It will also be useful to researchers working actively in the field, acting as a guide for carrying out experiments and interpreting experimental observations.

Sample Introduction Systems in ICPMS and ICPOES

Sample Introduction Systems in ICPMS and ICPOES PDF Author: Diane Beauchemin
Publisher: Newnes
ISBN: 0444594833
Category : Science
Languages : en
Pages : 588

Book Description
Sample Introduction Systems in ICPMS and ICPOES provides an in-depth analysis of sample introduction strategies, including flow injection analysis and less common techniques, such as arc/spark ablation and direct sample insertion. The book critically evaluates what has been accomplished so far, along with what can be done to extend the capabilities of the technique for analyses of any type of sample, such as aqueous, gaseous or solid. The latest progress made in fields, such as FIA, ETV, LC-ICP-MS and CE-ICP-MS is included and critically discussed. The book addresses problems related to the optimization of the system, peak dispersion and calibration and automatization. - Provides contributions from recognized experts that give credibility to each chapter as a reference source - Presents a single source, providing the big picture for ICPMS and ICPOES - Covers theory, methods, selected applications and discrete sampling techniques - Includes access to core data for practical work, comparison of results and decision-making

Atmospheric Pressure Plasma

Atmospheric Pressure Plasma PDF Author: Anton Nikiforov
Publisher: BoD – Books on Demand
ISBN: 1838802495
Category : Science
Languages : en
Pages : 146

Book Description
Plasma as the fourth state of matter is an ionized gas consisting of both negative and positive ions, electrons, neutral atoms, radicals, and photons. In the last few decades, atmospheric-pressure plasmas have started to attract increasing attention from both scientists and industry due to a variety of potential applications. Because of increasing interest in the topic, the focus of this book is on providing engineers and scientists with a fundamental understanding of the physical and chemical properties of different atmospheric-pressure plasmas via plasma diagnostic techniques and their applications. The book has been organized into two parts. Part I focuses on the latest achievements in advanced diagnostics of different atmospheric-pressure plasmas. Part II deals with applications of different atmospheric-pressure plasmas.

Scientific and Technical Aerospace Reports

Scientific and Technical Aerospace Reports PDF Author:
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 312

Book Description


Modern Multivariate Statistical Techniques

Modern Multivariate Statistical Techniques PDF Author: Alan J. Izenman
Publisher: Springer Science & Business Media
ISBN: 0387781897
Category : Mathematics
Languages : en
Pages : 757

Book Description
This is the first book on multivariate analysis to look at large data sets which describes the state of the art in analyzing such data. Material such as database management systems is included that has never appeared in statistics books before.

Encyclopedic Dictionary of Condensed Matter Physics

Encyclopedic Dictionary of Condensed Matter Physics PDF Author: Charles P. Poole Jr.
Publisher: Academic Press
ISBN: 0080545238
Category : Technology & Engineering
Languages : en
Pages : 1658

Book Description
This volume is a translation and revision of the Original Russian version by Baryahktar. It covers all of the main fields involved in Condensed Matter Physics, such as crystallography, electrical properties, fluids, magnetism, material properties, optics, radiation, semiconductors, and superconductivity, as well as highlights of important related subjects such as quantum mechanics, spectroscopy, and statistical mechanics. Both theoretical and experimental aspects of condensed matter are covered in detail. The entries range from very short paragraphs on topics where definitions are needed, such as Bloch's law, clathrate compound, donor, domain, Kondo lattice, mean free path, and Wigner crystal, to long discussions of more general or more comprehensive topics such as antiferromagnetism, crystal lattice dynamics, dislocations, Fermi surface, Josephson effect, luminescence, magnetic films, phase transitions and semiconductors. The main theoretical approaches to Condensed Matter Physics are explained. There are several long tables on, for example, Bravais lattices, characteristics of magnetic materials, units of physical quantities, symmetry groups. The properties of the main elements of the periodic table are given. Numerous entries not covered by standard Solid State Physics texts o Self-similarity o The adiabatic approximation o Bistability Emphasis on materials not discussed in standard texts o Activated carborn o Austenite o Bainite o Calamitics o Carbine o Delat phase o Discotics o Gunier-Preston zones o Heterodesmic structures o Heusler Alloys o Stress and strain deviators o Vicalloy · Each entry is fully cross-referenced to help tracking down all aspects of a topic under investigation Highly illustrated to clarify many concepts

Low Temperature Plasma Technology

Low Temperature Plasma Technology PDF Author: Paul K. Chu
Publisher: CRC Press
ISBN: 1466509910
Category : Science
Languages : en
Pages : 488

Book Description
Written by a team of pioneering scientists from around the world, Low Temperature Plasma Technology: Methods and Applications brings together recent technological advances and research in the rapidly growing field of low temperature plasmas. The book provides a comprehensive overview of related phenomena such as plasma bullets, plasma penetration i