Development of Isotope Dilution Gamma-ray Spectrometry for Plutonium Analysis PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Development of Isotope Dilution Gamma-ray Spectrometry for Plutonium Analysis PDF full book. Access full book title Development of Isotope Dilution Gamma-ray Spectrometry for Plutonium Analysis by . Download full books in PDF and EPUB format.

Development of Isotope Dilution Gamma-ray Spectrometry for Plutonium Analysis

Development of Isotope Dilution Gamma-ray Spectrometry for Plutonium Analysis PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Book Description
We are studying the feasibility of determining the plutonium concentration and isotopic distribution of highly radioactive, spent-fuel dissolver solutions by employing high-resolution gamma-ray spectrometry. The study involves gamma-ray plutonium isotopic analysis for both dissolver and spiked dissolver solution samples, after plutonium is eluted through an ion-exchange column and absorbed in a small resin bead bag. The spike is well characterized, dry plutonium containing (approximately)98% of 239Pu. By using measured isotopic information, the concentration of elemental plutonium in the dissolver solution can be determined. Both the plutonium concentration and the isotopic composition of the dissolver solution obtained from this study agree well with values obtained by traditional isotope dilution mass spectrometry (IDMS). Because it is rapid, easy to operate and maintain, and costs less, this new technique could be an alternative method to IDMS for input accountability and verification measurements in reprocessing plants. 7 refs., 4 figs., 4 tabs.

Development of Isotope Dilution Gamma-ray Spectrometry for Plutonium Analysis

Development of Isotope Dilution Gamma-ray Spectrometry for Plutonium Analysis PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Book Description
We are studying the feasibility of determining the plutonium concentration and isotopic distribution of highly radioactive, spent-fuel dissolver solutions by employing high-resolution gamma-ray spectrometry. The study involves gamma-ray plutonium isotopic analysis for both dissolver and spiked dissolver solution samples, after plutonium is eluted through an ion-exchange column and absorbed in a small resin bead bag. The spike is well characterized, dry plutonium containing (approximately)98% of 239Pu. By using measured isotopic information, the concentration of elemental plutonium in the dissolver solution can be determined. Both the plutonium concentration and the isotopic composition of the dissolver solution obtained from this study agree well with values obtained by traditional isotope dilution mass spectrometry (IDMS). Because it is rapid, easy to operate and maintain, and costs less, this new technique could be an alternative method to IDMS for input accountability and verification measurements in reprocessing plants. 7 refs., 4 figs., 4 tabs.

Further Development of IDGS

Further Development of IDGS PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 8

Book Description
The isotope dilution gamma-ray spectrometry (IDGS) technique for determining the plutonium concentration and isotopic composition of highly radioactive spent-fuel dissolver solutions has been further developed. Both the sample preparation and the analysis have been improved. The plutonium isotopic analysis is based on high-resolution, low-energy gamma-ray spectrometry. The plutonium concentration in the dissolver solutions then is calculated from the measured isotopic differences among the spike, the dissolver solution, and the spiked dissolver solution. Plutonium concentrations and isotopic compositions of dissolver solutions analyzed from this study agree well with those obtained by traditional isotope dilution mass spectrometry (IDMS) and are consistent with the first IDGS experimental result. With the current detector efficiency, sample size, and a 100-min count time, the estimated precision is (approximately)0.5% for 239Pu and 24°Pu isotopic analyses and (approximately)1% for the plutonium concentration analysis. 5 refs., 2 figs., 7 tabs.

Staatistische Wohl-gegründte Glaubens-Articul

Staatistische Wohl-gegründte Glaubens-Articul PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 8

Book Description


Evaluation of TASTEX Task H

Evaluation of TASTEX Task H PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
This report describes a computer-based gamma spectrometer system that was developed for measuring isotopic and total plutonium concentrations in nitric acid solutions. The system was installed at the Tokai reprocessing plant where it is undergoing testing and evaluation as part of the Tokai Advanced Safeguards Exercise (TASTEX). Objectives of TASTEX Task H, High-Resolution Gamma Spectrometer for Plutonium Isotopic Analysis, the methods and equipment used, the installation and calibration of the system, and the measurements obtained from several reprocessing campaigns are discussed and described. In general, we find that measurements for gamma spectroscopy agree well with those of mass spectrometry and of other chemical analysis. The system measures both freshly processed plutonium from the product accountability tank and aged plutonium solutions from storage tanks. 14 figures, 15 tables.

Determination of Plutonium Concentration and Isotopic Compositions by Isotope Dilution Gamma-ray Spectroscopy on Resin Beads

Determination of Plutonium Concentration and Isotopic Compositions by Isotope Dilution Gamma-ray Spectroscopy on Resin Beads PDF Author: T. K. Li
Publisher:
ISBN:
Category : Gamma ray spectrometry
Languages : en
Pages : 16

Book Description


Plutonium Isotopic Analysis of Nondescript Samples by Gamma-ray Spectrometry

Plutonium Isotopic Analysis of Nondescript Samples by Gamma-ray Spectrometry PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
A gamma-ray spectrometry system has been developed for the Savannah River Plant that when coupled with calorimetry will allow a complete nondestructive assay of various plutonium product and waste materials contained in sealed cans. The computer-based system employs two germanium detectors to obtain spectral information that is analyzed in a unique fashion to obtain plutonium isotopic ratios.

Determination o

Determination o PDF Author: T.K. Li
Publisher:
ISBN:
Category :
Languages : en
Pages : 14

Book Description


High-resolution Gamma-ray Isotopic Measurements of Uranium Plutonium Samples at IPPE in Support of Physical Inventory Taking Activities

High-resolution Gamma-ray Isotopic Measurements of Uranium Plutonium Samples at IPPE in Support of Physical Inventory Taking Activities PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Measurement of various U and Pu samples by gamma-ray spectrometry were performed at the Institute of Physics and Power Engineering to support physical-inventory-taking activities under the Joint US-Russian MPC and A Program. The resulting data was analyzed by several different methods which included Canberra's MGA9.63 (Pu and MOX analysis) and MGAU (U analysis), EG and G Ortec's MGA++ (Pu and MOX analysis) and U235 (U analysis), and FRAM v2.2 (U and Pu analysis) provided by Los Alamos. The results indicate that all of these codes are capable of performing the isotopic analysis adequately. However, some additional modifications may be required to permit better measurement of some of the more unusual components in the Institute of Physics and Power Engineering (IPPE) inventory to meet the demands of inventory-taking activities.

Plutonium and Uranium Isotopic Analysis

Plutonium and Uranium Isotopic Analysis PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
The Lawrence Livermore National Laboratory develops sophisticated gamma-ray analysis codes for isotopic determinations of nuclear materials based on the principles of the MultiGroup Analysis (MGA). MGA methodology has been upgraded and expanded and is now comprised of a suite of codes known as MGA++. A graphical user interface has also been developed for viewing the data and the fitting procedure. The code suite provides plutonium and uranium isotopic analysis for data collected with high-purity germanium planar and/or coaxial detector systems. The most recent addition to the MGA++ code suite, MGAHI, analyzes Pu data using higher-energy gamma rays (200 keV and higher) and is particularly useful for Pu samples that are enclosed in thick-walled containers. Additionally, the code suite can perform isotopic analysis of uranium spectra collected with cadmium-zinc-telluride (CZT) detectors. We are currently developing new codes with will integrate into the MGA++ suite. These will include Pu isotopic analysis capabilities for data collected with CZT detectors, and U isotopic analysis with high-purity germanium detectors, which utilizes only higher energy gamma rays. Future development of MGA++ will include a capability for isotopic analyses on mixtures of Pu and U.

Measurement of Plutonium and Uranium Isotopic Abundances by Gamma-ray Spectrometry

Measurement of Plutonium and Uranium Isotopic Abundances by Gamma-ray Spectrometry PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Book Description
The isotopic composition of plutonium and uranium is needed for purposes of sample confirmation, or for interpreting results from calorimeters or neutron-coincidence measurement instruments to determine nuclear material mass. The authors have developed measurement methods and computer codes utilizing high-resolution gamma-ray spectrometry to measure the relative isotopic abundances of plutonium and uranium in various forms nondestructively. The computer codes, known as MGA and MGAU, have unique analysis methodologies that the authors briefly describe in this paper.