Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H. PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H. PDF full book. Access full book title Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H. by M. A. Norato. Download full books in PDF and EPUB format.

Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H.

Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H. PDF Author: M. A. Norato
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Book Description
Researchers successfully demonstrated the chemistry of the Caustic-Side Solvent Extraction (CSSX) flow sheet with optimized solvent. This represents the third such process demonstration using actual Savannah River Site (SRS) high level waste (HLW). The present test differed from previous studies in the use of radioactive waste derived from Tank 37H dissolved salt cake, as opposed to supernate solutions used in previous demonstrations.

Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H.

Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H. PDF Author: M. A. Norato
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Book Description
Researchers successfully demonstrated the chemistry of the Caustic-Side Solvent Extraction (CSSX) flow sheet with optimized solvent. This represents the third such process demonstration using actual Savannah River Site (SRS) high level waste (HLW). The present test differed from previous studies in the use of radioactive waste derived from Tank 37H dissolved salt cake, as opposed to supernate solutions used in previous demonstrations.

High Level Waste Demonstration of the Caustic-Side Solvent Extraction Process with Optimized Solvent in the 2-CM Centrifugal Contactor Apparatus Using Tank 37H/44F Supernate

High Level Waste Demonstration of the Caustic-Side Solvent Extraction Process with Optimized Solvent in the 2-CM Centrifugal Contactor Apparatus Using Tank 37H/44F Supernate PDF Author: M. A. Norato
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Book Description
This report summarizes the results of tests at Savannah River Technology Center with radioactively spiked simulated Tank 37H/44F waste and actual Tank 37H/44F supernate composite waste. The spiked simulant tests demonstrated that stable hydraulic conditions could be maintained with the new solvent formulation and the radioactive feed could be decontaminated to background levels. The 24 hour actual Tank 37H/44F waste test demonstrated similar hydraulic stability and higher decontamination factors.

Advances in Inorganic Chemistry

Advances in Inorganic Chemistry PDF Author: Rudi van Eldik
Publisher: Elsevier
ISBN: 0080467385
Category : Science
Languages : en
Pages : 333

Book Description
This thematic issue devoted to 'Template Effects and Molecular Organization' is based on a special symposium recently organized by the American Chemical Society in Philadelphia. The authors contributed oral presentations and are experts in their fields. Each chapter is fully referenced Contains comprehensive reviews written by leading experts in the field Includes new information on the important advances in inorganic and bioinorganic chemistry

Demonstration of the Next-Generation Caustic-Side Solvent Extraction Solvent with 2-CM Centrifugal Contractors Using Tank 49H Waste and Waste Simulant

Demonstration of the Next-Generation Caustic-Side Solvent Extraction Solvent with 2-CM Centrifugal Contractors Using Tank 49H Waste and Waste Simulant PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Researchers successfully demonstrated the chemistry and process equipment of the Caustic-Side Solvent Extraction (CSSX) flowsheet using MaxCalix for the decontamination of high level waste (HLW). The demonstration was completed using a 12-stage, 2-cm centrifugal contactor apparatus at the Savannah River National Laboratory (SRNL). This represents the first CSSX process demonstration of the MaxCalix solvent system with Savannah River Site (SRS) HLW. Two tests lasting 24 and 27 hours processed non-radioactive simulated Tank 49H waste and actual Tank 49H HLW, respectively. Conclusions from this work include the following. The CSSX process is capable of reducing 137Cs in high level radioactive waste by a factor of more than 40,000 using five extraction, two scrub, and five strip stages. Tests demonstrated extraction and strip section stage efficiencies of greater than 93% for the Tank 49H waste test and greater than 88% for the simulant waste test. During a test with HLW, researchers processed 39 liters of Tank 49H solution and the waste raffinate had an average decontamination factor (DF) of 6.78E+04, with a maximum of 1.08E+05. A simulant waste solution (≈34.5 liters) with an initial Cs concentration of 83.1 mg/L was processed and had an average DF greater than 5.9E+03, with a maximum DF of greater than 6.6E+03. The difference may be attributable to differences in contactor stage efficiencies. Test results showed the solvent can be stripped of cesium and recycled for ≈25 solvent turnovers without the occurrence of any measurable solvent degradation or negative effects from minor components. Based on the performance of the 12-stage 2-cm apparatus with the Tank 49H HLW, the projected DF for MCU with seven extraction, two scrub, and seven strip stages operating at a nominal efficiency of 90% is ≈388,000. At 95% stage efficiency, the DF in MCU would be ≈3.2 million. Carryover of organic solvent in aqueous streams (and aqueous in organic streams) was less than 0.1% when processing Tank 49H HLW. The entrained solvent concentration measured in the decontaminated salt solution (DSS) was as much as ≈140 mg/L, although that value may be overstated by as much as 50% due to modifier solubility in the DSS. The entrained solvent concentration was measured in the strip effluent (SE) and the results are pending. A steady-state concentration factor (CF) of 15.9 was achieved with Tank 49H HLW. Cesium distribution ratios [D(Cs)] were measured with non-radioactive Tank 49H waste simulant and actual Tank 49H waste. Below is a comparison of D(Cs) values of ESS and 2-cm tests. Batch Extraction-Strip-Scrub (ESS) tests yielded D(Cs) values for extraction of ≈81-88 for tests with Tank 49H waste and waste simulant. The results from the 2-cm contactor tests were in agreement with values of 58-92 for the Tank 49H HLW test and 54-83 for the simulant waste test. These values are consistent with the reference D(Cs) for extraction of ≈60. In tests with Tank 49H waste and waste simulant, batch ESS tests measured D(Cs) values for the two scrub stages as ≈3.5-5.0 for the first scrub stage and ≈1.0-3.0 for the second scrub stage. In the Tank 49H test, the D(Cs) values for the 2-cm test were far from the ESS values. A D(Cs) value of 161 was measured for the first scrub stage and 10.8 for the second scrub stage. The data suggest that the scrub stage is not operating as effectively as intended. For the simulant test, a D(Cs) value of 1.9 was measured for the first scrub stage; the sample from the second scrub stage was compromised. Measurements of the pH of all stage samples for the Tank 49H test showed that the pH for extraction and scrub stages was 14 and the pH for the strip stages was ≈7. It is expected that the pH of the second scrub stage would be ≈12-13. Batch ESS tests measured D(Cs) values for the strip stages to be ≈0.002-0.010. A high value in Strip No.3 of a test with simulant solution has been attributed to issues associated with the limits of detection for the analytical method. In the 2-cm contactor tests, the first four strip stages of the Tank 49H waste test and all five strip stages in the simulant waste test had higher values than the ESS tests. Only the fifth strip stage D(Cs) value of the Tank 49H waste test matched that of the ESS tests. It is speculated that the less-than-optimal performance of the strip section is caused by inefficiencies in the scrub section. Because strip is sensitive to pH, the elevated pH value in the second scrub stage may be the cause of strip performance. In spite of the D(Cs) values obtained in the scrub and strip sections, testing showed that the solvent system is robust. Average DFs for the process far exceeded targets even though the scrub and strip stages did not function optimally. Correction of the issue in the scrub and strip stages is expected to yield even higher waste DFs.

Demonstration of the Next-Generation Caustic-Side Solvent Extraction Solvent with 2-CM Centrigugal Contractors Using Tank 49H Waste and Waste Simulant

Demonstration of the Next-Generation Caustic-Side Solvent Extraction Solvent with 2-CM Centrigugal Contractors Using Tank 49H Waste and Waste Simulant PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Researchers successfully demonstrated the chemistry and process equipment of the Caustic-Side Solvent Extraction (CSSX) flowsheet using MaxCalix for the decontamination of high level waste (HLW). The demonstration was completed using a 12-stage, 2-cm centrifugal contactor apparatus at the Savannah River National Laboratory (SRNL). This represents the first CSSX process demonstration of the MaxCalix solvent system with Savannah River Site (SRS) HLW. Two tests lasting 24 and 27 hours processed non-radioactive simulated Tank 49H waste and actual Tank 49H HLW, respectively. A solvent extraction system for removal of cesium from alkaline solutions was developed utilizing a novel solvent invented at the Oak Ridge National Laboratory (ORNL). This solvent consists of a calix[4]arene-crown-6 extractant dissolved in an inert hydrocarbon matrix. A modifier is added to the solvent to enhance the extraction power of the calixarene and to prevent the formation of a third phase. An additional additive is used to improve stripping performance and to mitigate the effects of any surfactants present in the feed stream. The process that deploys this solvent system is known as Caustic Side Solvent Extraction (CSSX). The solvent system has been deployed at the Savannah River Site (SRS) in the Modular CSSX Unit (MCU) since 2008.

Demonstration of Caustic-Side Solvent Extraction with Savannah River Site High Level Waste

Demonstration of Caustic-Side Solvent Extraction with Savannah River Site High Level Waste PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Book Description
Researchers successfully demonstrated the chemistry and process equipment of the Caustic-Side Solvent Extraction (CSSX) flowsheet for the decontamination of high level waste using a 33-stage, 2-cm centrifugal contactor apparatus at the Savannah River Technology Center. This represents the first CSSX process demonstration using Savannah River Site (SRS) high level waste. Three tests lasting 6, 12, and 48 hours processed simulated average SRS waste, simulated Tank 37H/44F composite waste, and Tank 37H/44F high level waste, respectively.

Caustic-Side Solvent-Extraction Modeling for Hanford Interim Pretreatment System

Caustic-Side Solvent-Extraction Modeling for Hanford Interim Pretreatment System PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
The purpose of this work is to examine the applicability of the Caustic-Side Solvent Extraction (CSSX) process for the removal of cesium from Hanford tank-waste supernatant solutions in support of the Hanford Interim Pretreatment System (IPS). The Hanford waste types are more challenging than those at the Savannah River Site (SRS) in that they contain significantly higher levels of potassium, the chief competing ion in the extraction of cesium. It was confirmed by use of the CSSX model that the higher levels of potassium depress the cesium distribution ratio (DCs), as validated by measurement of DCs values for four of eight specified Hanford waste-simulant compositions. The model predictions were good to an apparent standard error of ±11%. It is concluded from batch distribution experiments, physical-property measurements, equilibrium modeling, flowsheet calculations, and contactor sizing that the CSSX process as currently employed for cesium removal from alkaline salt waste at the SRS is capable of treating similar Hanford tank feeds. For the most challenging waste composition, 41 stages would be required to provide a cesium decontamination factor (DF) of 5000 and a concentration factor (CF) of 5. Commercial contacting equipment with rotor diameters of 10 in. for extraction and 5 in. for stripping should have the capacity to meet throughput requirements, but testing will be required to confirm that the needed efficiency and hydraulic performance are actually obtainable. Markedly improved flowsheet performance was calculated for a new solvent formulation employing the more soluble cesium extractant BEHBCalixC6 used with alternative scrub and strip solutions, respectively 0.1 M NaOH and 10 mM boric acid. The improved system can meet minimum requirements (DF = 5000 and CF = 5) with 17 stages or more ambitious goals (DF = 40,000 and CF = 15) with 19 stages. Potential benefits of further research and development are identified that would lead to reduced costs, greater adaptability of the process to DOE alkaline salt wastes, and greater readiness for implementation. Such benefits accrue from optimal sizing of centrifugal contactors for application of the CSSX process for the IPS; more accurate modeling of cesium extraction with greater flexibility and applicability to a variety of feeds and flowsheet conditions; and further improving and optimizing the alternative CSSX solvent and scrub/strip system.

Caustic-Side Solvent Extraction

Caustic-Side Solvent Extraction PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Book Description
This work was undertaken to optimize the solvent used in the Caustic Side Solvent Extraction (CSSX) process and to measure key chemical and physical properties related to its performance in the removal of cesium from the alkaline high-level salt waste stored in tanks at the Savannah River Site. The need to adjust the solvent composition arose from the prior discovery that the previous baseline solvent was supersaturated with respect to the calixarene extractant. The following solvent-component concentrations in Isopar{reg_sign} L diluent are recommended: 0.007 M calix[4]arene-bis(tert-octylbenzo-crown-6) (BOBCalixC6) extractant, 0.75 M 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol (Cs-7SB) phase modifier, and 0.003 M tri-n-octylamine (TOA) stripping aid. Criteria for this selection included BOBCalixC6 solubility, batch cesium distribution ratios (D{sub Cs}), calculated flowsheet robustness, third-phase formation, coalescence rate (dispersion numbers), and solvent density. Although minor compromises within acceptable limits were made in flowsheet robustness and solvent density, significant benefits were gained in lower risk of third-phase formation and lower solvent cost. Data are also reported for the optimized solvent regarding the temperature dependence of D{sub Cs} in extraction, scrubbing, and stripping (ESS); ESS performance on recycle; partitioning of BOBCalixC6, Cs-7SB, and TOA to aqueous process solutions; partitioning of organic anions; distribution of metals; solvent phase separation at low temperatures; solvent stability to elevated temperatures; and solvent density and viscosity. Overall, the technical risk of the CSSX process has been reduced by resolving previously identified issues and raising no new issues.

Antonius und Kleopatra

Antonius und Kleopatra PDF Author: Hermann Conrad
Publisher:
ISBN:
Category :
Languages : en
Pages : 110

Book Description


Evaluation of Mass Transfer Performance for Caustic-Side Solvent Extraction of Cesium in a Conventional 5-cm Centrifugal Contactor

Evaluation of Mass Transfer Performance for Caustic-Side Solvent Extraction of Cesium in a Conventional 5-cm Centrifugal Contactor PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 31

Book Description
Tests have been conducted to determine if satisfactory mass transfer performance is achieved using a fully pumping 5-cm centrifugal contactor under conditions present in the Caustic-Side Solvent Extraction (CSSX) process. Tests utilized a commercially available contactor that had been modified by installation of a rotor housing bottom that had straight radial vanes on the process side. As received from the vendor, the housing bottom was equipped with curved (impeller-type) vanes that were intended to promote phase separation by minimizing mixing of influent solutions. Stage efficiencies exceeding 85% were obtained under conditions, present in the extraction section of the CSSX flowsheet. Under CSSX stripping conditions the stage efficiency exceeded 90%. In both cases, the efficiencies obtained exceed the minimum requirement for acceptable transfer of cesium in the CSSX process.