Attenuation Correction of Positron Emission Tomography Data Using Post-processed Attenuation Images PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Attenuation Correction of Positron Emission Tomography Data Using Post-processed Attenuation Images PDF full book. Access full book title Attenuation Correction of Positron Emission Tomography Data Using Post-processed Attenuation Images by Rajeshwari Srinivasan. Download full books in PDF and EPUB format.

Attenuation Correction of Positron Emission Tomography Data Using Post-processed Attenuation Images

Attenuation Correction of Positron Emission Tomography Data Using Post-processed Attenuation Images PDF Author: Rajeshwari Srinivasan
Publisher:
ISBN:
Category :
Languages : en
Pages : 182

Book Description


Attenuation Correction of Positron Emission Tomography Data Using Post-processed Attenuation Images

Attenuation Correction of Positron Emission Tomography Data Using Post-processed Attenuation Images PDF Author: Rajeshwari Srinivasan
Publisher:
ISBN:
Category :
Languages : en
Pages : 182

Book Description


Mathematics and Physics of Emerging Biomedical Imaging

Mathematics and Physics of Emerging Biomedical Imaging PDF Author: Committee on the Mathematics and Physics of Emerging Dynamic Biomedical Imaging
Publisher: National Academies Press
ISBN: 0309552923
Category : Science
Languages : en
Pages : 261

Book Description
This cross-disciplinary book documents the key research challenges in the mathematical sciences and physics that could enable the economical development of novel biomedical imaging devices. It is hoped that the infusion of new insights from mathematical scientists and physicists will accelerate progress in imaging. Incorporating input from dozens of biomedical researchers who described what they perceived as key open problems of imaging that are amenable to attack by mathematical scientists and physicists, this book introduces the frontiers of biomedical imaging, especially the imaging of dynamic physiological functions, to the educated nonspecialist. Ten imaging modalities are covered, from the well-established (e.g., CAT scanning, MRI) to the more speculative (e.g., electrical and magnetic source imaging). For each modality, mathematics and physics research challenges are identified and a short list of suggested reading offered. Two additional chapters offer visions of the next generation of surgical and interventional techniques and of image processing. A final chapter provides an overview of mathematical issues that cut across the various modalities.

Correction Techniques in Emission Tomography

Correction Techniques in Emission Tomography PDF Author: Mohammad Dawood
Publisher: CRC Press
ISBN: 1439812985
Category : Medical
Languages : en
Pages : 304

Book Description
Written by an interdisciplinary team of medical doctors, computer scientists, physicists, engineers, and mathematicians, Correction Techniques in Emission Tomography presents various correction methods used in emission tomography to generate and enhance images. It discusses the techniques from a computer science, mathematics, and physics viewpoint. The book gives a comprehensive overview of correction techniques at different levels of the data processing workflow. It covers nuclear medicine imaging, hybrid emission tomography (PET-CT, SPECT-CT, PET-MRI, PET-ultrasound), and optical imaging (fluorescence molecular tomography). It illustrates basic principles as well as recent advances, such as model-based iterative algorithms and 4D methods. An important aspect of the book is on new and sophisticated motion correction techniques in PET imaging. These techniques enable high-resolution, high-quality images, leading to better imaging analysis and image-based diagnostics. Reflecting state-of-the-art research, this volume explores the range of problems that occur in emission tomography. It looks at how the resulting images are affected and presents practical compensation methods to overcome the problems and improve the images.

Image Synthesis for the Attenuation Correction and Analysis of PET/MR Data

Image Synthesis for the Attenuation Correction and Analysis of PET/MR Data PDF Author: Ninon Burgos
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Book Description


Ultra-low-dose CT-based Attenuation Correction for Respiratory Motion Compensation in PET/CT Imaging

Ultra-low-dose CT-based Attenuation Correction for Respiratory Motion Compensation in PET/CT Imaging PDF Author: Tzu-Cheng Lee
Publisher:
ISBN:
Category :
Languages : en
Pages : 153

Book Description
Positron emission tomography (PET) is a commonly used imaging tool in the management of patients with lung cancer and is of considerable interest in quantitative imaging of the thorax. Mismatch of PET data with computed tomography (CT) attenuation correction (CTAC) due to respiratory motion is a known source of errors in PET imaging. In theory, this can be corrected by matching individual PET and CT phases which have been generated by respiratory-correlated PET and CT. However, due to the high variability of patient breathing patterns and the nature of the scanning time differences between PET and CT, current respiratory-gated CTAC protocols for the irregular breather may cause additional bias in the PET image values. A ten-fold extension of the CT scanning time duration helps reduce PET imaging bias, but leads to the higher radiation dose to the patient. Lowering the CT source flux level to reduce dose, however, leads to increased noise and bias. Here we test the possibility of using model based iterative reconstruction algorithms (MBIRs) for generating the sparse-view, ultra-low-dose (i.e. an order lower than current low-dose protocols) CTAC images for both phantom and patient PET data. We also propose a new variance estimation model, which considers statistical changes caused by the non-positivity correction process, for the MBIR algorithms. The model based iterative CT reconstruction approach does generate more accurate CTAC map compared to current approaches. However, since iterative reconstruction algorithms typically assume a normal distribution of the attenuation data, we tested if the assumption is still valid in the ultra-low-dose regime. The simulation and empirical ultra-low-dose CT studies showed a skewed post-log likelihood distribution in certain ranges. The information delineates the estimation limits of model based iterative reconstruction approach on the ultra-low-dose CT imaging, and potentially helps guide scanning protocols customized for a lowest-reasonable radiation dose.

Positron Emission Tomography

Positron Emission Tomography PDF Author: Dale L. Bailey
Publisher: Springer Science & Business Media
ISBN: 9781852334857
Category : Medical
Languages : en
Pages : 908

Book Description
Essential for students, science and medical graduates who want to understand the basic science of Positron Emission Tomography (PET), this book describes the physics, chemistry, technology and overview of the clinical uses behind the science of PET and the imaging techniques it uses. In recent years, PET has moved from high-end research imaging tool used by the highly specialized to an essential component of clinical evaluation in the clinic, especially in cancer management. Previously being the realm of scientists, this book explains PET instrumentation, radiochemistry, PET data acquisition and image formation, integration of structural and functional images, radiation dosimetry and protection, and applications in dedicated areas such as drug development, oncology, and gene expression imaging. The technologist, the science, engineering or chemistry graduate seeking further detailed information about PET, or the medical advanced trainee wishing to gain insight into the basic science of PET will find this book invaluable. This book is primarily repackaged content from the Basic Science section of the 'big' Valk book on PET. It contains new, completely revised and unchanged chapters covering the "basic sciences" section of the main book - total 18 chapters: 2 new (chapters 1, 16) 8 completely revised (chapters 4, 5, 8, 13, 14, 15, 17, 18) 3 minor corrections (chapters 2, 6, 11) 5 unchanged (chapters 3, 7, 9, 10, 12)

University of Copenhagen

University of Copenhagen PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 100

Book Description


Neuroimaging of Sleep and Sleep Disorders

Neuroimaging of Sleep and Sleep Disorders PDF Author: Eric Nofzinger
Publisher: Cambridge University Press
ISBN: 1107018633
Category : Medical
Languages : en
Pages : 445

Book Description
An up-to-date, superbly illustrated practical guide to the effective use of neuroimaging in the patient with sleep disorders. The only book to date to provide comprehensive coverage of this topic. A must for all healthcare workers interested in understanding the causes, consequences and treatment of sleep disorders.

Image Synthesis for the Attenuation Correction and Analysis of PET/MR Data

Image Synthesis for the Attenuation Correction and Analysis of PET/MR Data PDF Author: N. F. Burgos
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description


Quantification in Nuclear Medicine Imaging

Quantification in Nuclear Medicine Imaging PDF Author: Ivo Rausch
Publisher: Frontiers Media SA
ISBN: 2889741176
Category : Science
Languages : en
Pages : 141

Book Description