Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location PDF full book. Access full book title Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location by . Download full books in PDF and EPUB format.

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Exhaust Stack. The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow -angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Exhaust Stack. The 3430 stack was tested in both January and May of 2010 to document the results of several changes that were made to the exhaust system after the January tests. The 3430 stack meets the qualification criteria given in the American National Standards Institute/Health Physics Society N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliancewith the requirements.

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Exhaust Stack. The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow -angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Exhaust Stack. The 3430 stack was tested in both January and May of 2010 to document the results of several changes that were made to the exhaust system after the January tests. The 3430 stack meets the qualification criteria given in the American National Standards Institute/Health Physics Society N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliancewith the requirements.

Assessment of the Building 3430 Filtered Exhaust Stack Sampling Probe Location

Assessment of the Building 3430 Filtered Exhaust Stack Sampling Probe Location PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Pathway Stack . The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Pathway stack. Therefore, this new system also meets the qualification criteria given in the ANSI/HPS N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliance to the requirements.

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Pacific Northwest National Laboratory performed several tests in the exhaust air discharge from the new 3420 Building Filtered Exhaust Stack to determine whether the air sampling probe for emissions monitoring for radionuclides is acceptable. The method followed involved adopting the results of a previously performed test series from a system with a similar configuration, followed by several tests on the actual system to verify the applicability of the previously performed tests. The qualification criteria for these types of stacks include metrics concerning 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity tracer particle concentration.

Assessment of the 3410 Building Filtered Exhaust Stack Sampling Probe Location

Assessment of the 3410 Building Filtered Exhaust Stack Sampling Probe Location PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Pacific Northwest National Laboratory performed several tests in the exhaust air discharge from the new 3410 Building Filtered Exhaust Stack to determine whether the air sampling probe for emissions monitoring for radionuclides is acceptable. The method followed involved adopting the results of a previously performed test series from a system with a similar configuration, followed by several tests on the actual system to verify the applicability of the previously performed tests. The qualification criteria for these types of stacks include metrics concerning 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity tracer particle concentration.

Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location

Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
In order to support the air emissions permit for the 3410 Building, Pacific Northwest National Laboratory performed a series of tests in the exhaust air discharge from the reconfigured 3410 Building Filtered Exhaust Stack. The objective was to determine whether the location of the air sampling probe for emissions monitoring meets the applicable regulatory criteria governing such effluent monitoring systems. In particular, the capability of the air sampling probe location to meet the acceptance criteria of ANSI/HPS N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities was determined. The qualification criteria for these types of stacks address 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity of tracer particle concentration. Testing was performed to conform to the quality requirements of NQA-1-2000. Fan configurations tested included all fan combinations of any two fans at a time. Most of the tests were conducted at the normal flow rate, while a small subset of tests was performed at a slightly higher flow rate achieved with the laboratory hood sashes fully open. The qualification criteria for an air monitoring probe location are taken from ANSI/HPS N13.1-2011 and are paraphrased as follows with key results summarized: 1. Angular Flow--The average air velocity angle must not deviate from the axis of the stack or duct by more than 20°. Our test results show that the mean angular flow angles at the center two-thirds of the ducts are smaller than 4.5% for all testing conditions. 2. Uniform Air Velocity--The acceptance criterion is that the COV of the air velocity must be d"20% across the center two thirds of the area of the stack. Our results show that the COVs of the air velocity across the center two-thirds of the stack are smaller than 2.9% for all testing conditions. 3. Uniform Concentration of Tracer Gases--The uniformity of the concentration of potential contaminants is first tested using a tracer gas to represent gaseous effluents. The tracer is injected downstream of the fan outlets and at the junction downstream fan discharges meet. The acceptance criteria are that 1) the COV of the measured tracer gas concentration is d"0% across the center two-thirds of the sampling plane and 2) at no point in the sampling plane does the concentration vary from the mean by>30%. Our test results show that 1) the COV of the measured tracer gas concentration is 2.9% for all test conditions and 2) at no point in the sampling plane does the concentration vary from the mean by6.5%. 4. Uniform Concentration of Tracer Particles--Tracer particles of 10-[mu]m aerodynamic diameter are used for the second demonstration of concentration uniformity. The acceptance criterion is that the COV of particle concentration is d"20% across the center two thirds of the sampling plane. Our test results indicate that the COV of particle concentration is

Assessment of the HV-C2 Stack Sampling Probe Location

Assessment of the HV-C2 Stack Sampling Probe Location PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
Tests were performed to evaluate the location of the air-sampling probe in the proposed design for the Waste Treatment Plant's HV-C2 air exhaust stack. The evaluation criteria come from ANSI/HPS N13.1-1999, "Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities." Pacific Northwest National Laboratory conducted the tests on a 3.67:1 scale model of the stack. Limited confirmatory tests on the actual stack will need to be conducted during cold startup of the High Level Waste Treatment Facility. The tests documented here assessed the capability of the air-monitoring probe to extract a sample representative of the effluent stream in accordance with criteria in ANSI/HPS N13.1. The test parameters covered the expected range of system flowrates with both one and two operating fans. The current stack design calls for the sampling probe to be located about 10 diameters downstream of the junction of the duct from Fan A with the stack. In accordance with the statement of work and the test plan, the test measurements were made at that location and also at one point upstream and another downstream. An adjustment was made for the distance between a typical sampling probe inlet and the centerline of its mounting flange. Thus, the test measurements were made at three positions designated as Test Port 1, 2, and 3, respectively. The designed HV-C2 exhaust system includes dampers on the fan discharges. Custom-scale model dampers were fabricated to simulate the same number and configuration of damper blades shown in the design documents received from BNI. A subset of the test runs was run without the dampers to determine whether the dampers should be included in future tests on scale models.

Assessment of the Group 5-6 (LB C2, LB S2, LV S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1 1999

Assessment of the Group 5-6 (LB C2, LB S2, LV S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1 1999 PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
This document reports on a series of tests to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 5-6 exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LB-C2, LV-S1, and LB S2 exhaust stacks were tested together as a group (Test Group 5-6) because the common factor in their design is that the last significant flow disturbance upstream of the air sampling probe is a reduction in duct diameter. Federal regulations() require that a sampling probe be located in the exhaust stack according to the criteria of the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The testing on scale models of the stacks conducted for this project was part of the River Protection Project--Waste Treatment Plant Support Program under Contract No. DE-AC05-76RL01830 according to the statement of work issued by Bechtel National Inc. (BNI, 24590-QL-SRA-W000-00101, N13.1-1999 Stack Monitor Scale Model Testing and Qualification, Revision 1, 9/12/2007) and Work Authorization 09 of Memorandum of Agreement 24590-QL-HC9-WA49-00001. The internal Pacific Northwest National Laboratory (PNNL) project for this task is 53024, Work for Hanford Contractors Stack Monitoring. The testing described in this document was further guided by the Test Plan Scale Model Testing the Waste Treatment Plant LB-C2, LB-S2, and LV-S1 (Test Group 5-6) Stack Air Sampling Positions (TP-RPP-WTP-594). The tests conducted by PNNL during 2009 and 2010 on the Group 5-6 scale model systems are described in this report. The series of tests consists of various measurements taken over a grid of points in the duct cross-section at the designed sampling probe locations and at five duct diameters up and downstream from the design location to accommodate potential construction variability. The tests were done only at the design sampling probe location on the scale model of LB-S2 because that ductwork was already constructed. The ANSI/HPS N13.1-1999 criteria and the corresponding results of the test series on the scale models are summarized in this report.

Assessment of the Group 3-4 (HV-S1, HV-S2, IHLW-S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

Assessment of the Group 3-4 (HV-S1, HV-S2, IHLW-S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999 PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description


Extrusion

Extrusion PDF Author: Harold F. Giles Jr
Publisher: William Andrew
ISBN: 1437734820
Category : Technology & Engineering
Languages : en
Pages : 638

Book Description
The second edition of Extrusion is designed to aid operators, engineers, and managers in extrusion processing in quickly answering practical day-to-day questions. The first part of the book provides the fundamental principles, for operators and engineers, of polymeric materials extrusion processing in single and twin screw extruders. The next section covers advanced topics including troubleshooting, auxiliary equipment, and coextrusion for operators, engineers, and managers. The final part provides applications case studies in key areas for engineers such as compounding, blown film, extrusion blow molding, coating, foam, and reprocessing. This practical guide to extrusion brings together both equipment and materials processing aspects. It covers basic and advanced topics, for reference and training, in thermoplastics processing in the extruder. Detailed reference data are provided on such important operating conditions as temperatures, start-up procedures, shear rates, pressure drops, and safety. - A practical guide to the selection, design and optimization of extrusion processes and equipment - Designed to improve production efficiency and product quality - Focuses on practical fault analysis and troubleshooting techniques

Carbon Black

Carbon Black PDF Author: Jean-Baptiste Donnet
Publisher: Routledge
ISBN: 135146261X
Category : Science
Languages : en
Pages : 484

Book Description
The second edition of this reference provides comprehensive examinations of developments in the processing and applications of carbon black, including the use of new analytical tools such as scanning tunnelling microscopy, Fourier transform infrared spectroscopy and inverse gas chromatography.;Completely rewritten and updated by numerous experts in the field to reflect the enormous growth of the field since the publication of the previous edition, Carbon Black: discusses the mechanism of carbon black formation based on recent advances such as the discovery of fullerenes; elucidates micro- and macrostructure morphology and other physical characteristics; outlines the fractal geometry of carbon black as a new approach to characterization; reviews the effect of carbon black on the electrical and thermal conductivity of filled polymers; delineates the applications of carbon black in elastomers, plastics, and zerographic toners; and surveys possible health consequences of exposure to carbon black.;With over 1200 literature citations, tables, and figures, this resource is intended for physical, polymer, surface and colloid chemists; chemical and plastics engineers; spectroscopists; materials scientists; occupational safety and health physicians; and upper-level undergraduate and graduate students in these disciplines.