An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu PDF full book. Access full book title An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu by . Download full books in PDF and EPUB format.

An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu

An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Book Description
We have designed and built a gamma-ray spectrometer system that measures the relative plutonium isotopic abundances of plutonium oxide enriched in 238Pu. The first system installed at Westinghouse Savannah River Company was tested and evaluated on plutonium oxide in stainless steel EP60/61 containers. 238Pu enrichments ranged from 20% to 85%. Results show that 200 grams of plutonium oxide in an EP60.61 container can be measured with {plus minus}0.3% precision and better than {plus minus}1.0% accuracy in the specific power using a counting time of 50 minutes. 3 refs., 2 figs.

An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu

An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Book Description
We have designed and built a gamma-ray spectrometer system that measures the relative plutonium isotopic abundances of plutonium oxide enriched in 238Pu. The first system installed at Westinghouse Savannah River Company was tested and evaluated on plutonium oxide in stainless steel EP60/61 containers. 238Pu enrichments ranged from 20% to 85%. Results show that 200 grams of plutonium oxide in an EP60.61 container can be measured with {plus minus}0.3% precision and better than {plus minus}1.0% accuracy in the specific power using a counting time of 50 minutes. 3 refs., 2 figs.

Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60

Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60 PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 285

Book Description
This software manual is addressed to the Westinghouse Hanford's Radioisotope Power Systems Facility personnel (programmers and supervisors) who maintain the software on the Pu-238 isotopic analysis system. The document is divided into two parts. Part 1 describes the computer codes that control the system, analyze the spectral data, and determine the relative plutonium abundances. Part 2 contains the software listing of the analysis codes.

Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60/61 Containers

Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60/61 Containers PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 80

Book Description
This user's manual is addressed to the Savannah River Site personnel (routine operators and supervisors) who perform measurements with the Pu-238 isotopic analysis system. Each chapter begins with a table of contents that lists the section title, illustrations, and tabular data presented in that chapter. The first chapter in this manual is an introduction to the system. Chapter 2 lists required settings for the system's commercial nuclear instrument modules. System operating procedures are given in Chapter 3. Chapter 4 contains routine and supervisorial operator interactions. Chapter 5 describes the system's short- and long-printout output formats. Chapter 6 gives instructions for changing system parameters. Error messages are listed and described Chapter 7. Chapter 8 contains a reference article on measuring relative plutonium isotopics in plutonium samples enriched in Pu-238. All commercial items mentioned in this manual are assumed to be functioning correctly for the purposes of system operation. Users are referred to individual equipment manufacturers' manuals for details of operation, trouble-shooting, and maintenance of this commercial equipment.

Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60/61 and Fuel-clad Containers

Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60/61 and Fuel-clad Containers PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 72

Book Description
This user's manual is addressed to the Hanford Site personnel (routine operators and supervisors) who perform measurements with the Pu-238 isotopic analysis system. Each chapter begins with a table of contents that lists the section titles, illustrations, and tabular data presented in that chapter. The first chapter in this manual is an introduction to the system. Chapter 2 lists required settings for the system's commercial nuclear instrument modules. System operating procedures are given in Chapter 3. Chapter 4 contains routine and supervisorial operator interactions. Chapter 5 describes the system's short- and long-printout output formats. Chapter 6 gives instructions for changing system parameters. Error messages are listed and described in Chapter 7. Chapter 8 contains reference articles on measuring relative plutonium isotopics in solid samples.

Plutonium Isotopic Analysis of Highly Enriched Mixed Oxides

Plutonium Isotopic Analysis of Highly Enriched Mixed Oxides PDF Author: Steven D. Clement
Publisher:
ISBN:
Category : Plutonium
Languages : en
Pages : 15

Book Description


Plutonium Isotopic Measurement for Small Product Samples

Plutonium Isotopic Measurement for Small Product Samples PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
An automated at-line plutonium isotopic analysis system for small-product plutonium samples in the range of 10 to 1000 .mu.g has been developed. The analysis is based on low-energy gamma rays at 43.48 keV (238Pu), 45.23 keV (24°Pu), 51.63 keV (239Pu), 64.83 keV (241Pu-237U), 129.3 keV (239Pu), and 148.6 keV (241Pu). Within a 20-ks counting time, we demonstrated that for plutonium masses> 600 .mu.g the precision is

Experience with a General Gamma-Ray Isotopic Analysis Approach

Experience with a General Gamma-Ray Isotopic Analysis Approach PDF Author: W. D. Ruhter
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
The gamma-ray data analysis methodology originally developed for the MGA code to determine the relative detection efficiency curve may also be used to determine the relative amounts of the isotopes being measured. This analysis approach is based on the fact that the intensity of any given gamma ray from a sample is determined by the amount of the emitting isotope present in the sample, the emission probability for the gamma ray being measured, the sample self attenuation, the attenuation due to absorbers between the sample and detector, and the detector efficiency. An equation can be written that describes a measured gamma-ray peak intensity in terms of these parameters. By selecting appropriate gamma-ray peaks from the isotopes of interest, we can solve a set of equations for the values of the parameters in any particular measurement including the relative amounts of the selected isotopes. The equations representing the peak intensities are very nonlinear and require an iterative least squares method to solve. We have developed software to ensure that during the iterative process the parameters stay within their appropriate ranges and converge properly in solving the set of equations under various measurement conditions. We have utilized and reported on this approach for determining the plutonium isotopic abundances in samples enriched in Pu-238 and to determine the U-235 enrichment of uranium samples in thick-walled containers. Recently, we have used this approach to determine the plutonium isotopic abundances of plutonium samples in thick-walled containers. We will report on this most recent application, and how this general approach can be adapted quickly to any isotopic analysis problem.

High-precision Isotopic Analysis of Nanogram Quantities of Plutonium

High-precision Isotopic Analysis of Nanogram Quantities of Plutonium PDF Author:
Publisher:
ISBN:
Category : Plutonium
Languages : en
Pages : 0

Book Description
A surface ionization-diffusion-type ionization source that uses a rhenium filament overplated with platinum has been developed and optimized for 0.5- to 2-ng plutonium samples. This source is capable of measuring the /sup 240/Pu//sup 239/Pu atom ratio in nuclear-test-debris samples to 0.15% precision and accuracy at the 95% confidence level.

Simplified Method for the Preparation of Micro Samples for the Simultaneous Isotopic Analysis of Uranium and Plutonium

Simplified Method for the Preparation of Micro Samples for the Simultaneous Isotopic Analysis of Uranium and Plutonium PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Book Description
A basic anion resin is employed to selectively adsorb plutonium and uranium from 8 M HNO3 solutions containing dissolved spent reactor fuels. After a few beads of the resin are equilibrated with the solution, a single bead is used for establishing the isotopic composition of plutonium and uranium. The resin bead separation essentially removes all possible isobaric interference from such elements as americium and curium and at the same time eliminates most fission product contamination in the mass spectrometer. Small aliquots of dissolver solution that contain 10−6g of U and 10−8 g of Pu are adequate for preparing about ten resin beads. By employing a single-focusing, tandem-magnet-type mass spectrometer, equipped with pulse counting for ion detection, simultaneous plutonium and uranium assays are obtained. The quantity of each element per bead may be as low as 10−9 to 10−1°g. The technique of isotope dilution can be coupled with the ion exchange bead separation and used effectively for measuring the total quantity of U and Pu. The technique possesses advantages such as: reduced radiation hazards from the infinitely smaller samples, thus less shielding and transport cost for sample handling; greatly simplified chemical preparations that eliminate fission products and actinide isobaric interferences; and the minor isotopes are more precisely established. (auth).

Energy Research Abstracts

Energy Research Abstracts PDF Author:
Publisher:
ISBN:
Category : Power resources
Languages : en
Pages : 488

Book Description