Author: Y. Alexahin
Publisher:
ISBN:
Category :
Languages : en
Pages : 3
Book Description
The Fourier analysis of Turn by Turn (TBT) data provides valuable information about the machine linear and non-linear optics. A program for the measurement and correction of the linear coupling based on the TBT data analysis has been integrated in the TEVATRON control system. The new method is fast, allows the measurement of the coupling during acceleration and offers information about the sum coupling coefficient and the location of the sources of coupling.
A New Algorithm for the Correction of the Linear Coupling at Tevatron
Author: Y. Alexahin
Publisher:
ISBN:
Category :
Languages : en
Pages : 3
Book Description
The Fourier analysis of Turn by Turn (TBT) data provides valuable information about the machine linear and non-linear optics. A program for the measurement and correction of the linear coupling based on the TBT data analysis has been integrated in the TEVATRON control system. The new method is fast, allows the measurement of the coupling during acceleration and offers information about the sum coupling coefficient and the location of the sources of coupling.
Publisher:
ISBN:
Category :
Languages : en
Pages : 3
Book Description
The Fourier analysis of Turn by Turn (TBT) data provides valuable information about the machine linear and non-linear optics. A program for the measurement and correction of the linear coupling based on the TBT data analysis has been integrated in the TEVATRON control system. The new method is fast, allows the measurement of the coupling during acceleration and offers information about the sum coupling coefficient and the location of the sources of coupling.
LINEAR COUPLING CORRECTION WITH N-TURN MAPS.
Author: W. FISCHER
Publisher:
ISBN:
Category :
Languages : en
Pages : 3
Book Description
The linear one-turn map of a storage ring contains coupling information on which a correction algorithm can be based. In principal, the one-turn matrix can be fitted from turn-by-turn data of beam position monitors after a kick was applied. However, the so obtained coupling information often sinks into the noise floor. The signal-to-noise ratio of the coupling information can be greatly enhanced by fitting maps for larger turn numbers N, equal to half the beat period. With the so obtained N-turn map an automated global coupling correction is possible without the need for a tune change. This is demonstrated for the Relativistic Heavy Ion Collider where the algorithm is implemented for operational use at injection.
Publisher:
ISBN:
Category :
Languages : en
Pages : 3
Book Description
The linear one-turn map of a storage ring contains coupling information on which a correction algorithm can be based. In principal, the one-turn matrix can be fitted from turn-by-turn data of beam position monitors after a kick was applied. However, the so obtained coupling information often sinks into the noise floor. The signal-to-noise ratio of the coupling information can be greatly enhanced by fitting maps for larger turn numbers N, equal to half the beat period. With the so obtained N-turn map an automated global coupling correction is possible without the need for a tune change. This is demonstrated for the Relativistic Heavy Ion Collider where the algorithm is implemented for operational use at injection.